Evaluation of Thermal Admittance of Compressed Earth Bricks C.E.B Configurations for School Buildings in Hot-dry climate region of North-western Nigeria

Pub Date : 2022-12-29 DOI:10.11113/ijbes.v10.n1.1069
Sanusi Sani Maimagani, R. A. Abdul Majid, Leng Pau Chung
{"title":"Evaluation of Thermal Admittance of Compressed Earth Bricks C.E.B Configurations for School Buildings in Hot-dry climate region of North-western Nigeria","authors":"Sanusi Sani Maimagani, R. A. Abdul Majid, Leng Pau Chung","doi":"10.11113/ijbes.v10.n1.1069","DOIUrl":null,"url":null,"abstract":"Permeation of heat into the school building enclosure through external walls components of the building resulting into the numerous consequences which causes unhealthy indoor living conditions for teaching and learning activities, which has a negative impacts on the students general academic performance and their productivity, the study carried out a fieldwork experimentation  where four experimental models (chambers) were built using four dissimilar  compressed earth (C.E.B) configurations; compressed earth horizontal hollow brick  (C.E.H.H.B), compressed earth vertical hollow brick (C.E.V.H.B), compressed earth cellular brick  (C.E.C.B), and compressed earth solid  brick  (C.E.S.B) respectively, data were collected from fieldwork experimental chambers using two distinct wall surface temperature measuring devices; an onset UX120-M600 4-channel analogue data logger and Testo 835 Infrared thermometer which were utilized to measure the interior wall surface temperature facing the west direction of each experimental chamber to determine the rate of thermal admittance of the entire chambers built with distinct C.E.B configurations, the extracted data using surface temperature measuring instrument were analyzed using the spss software package for identification of the C.E.B configurations with the least thermal permeation from outdoor environment to indoor space of the school building via external walls of the building. After the statistical analysis, the study's outcome revealed that compressed earth horizontal hollow brick (C.E.H.H.B) has a minimum heat transfer rate of (34.933OC) and (35.7493OC), among other C.E.B configurations. This undoubtedly indicated the appropriate C.E.B configurations for school buildings in hot-dry climate regions of northwestern Nigeria.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11113/ijbes.v10.n1.1069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Permeation of heat into the school building enclosure through external walls components of the building resulting into the numerous consequences which causes unhealthy indoor living conditions for teaching and learning activities, which has a negative impacts on the students general academic performance and their productivity, the study carried out a fieldwork experimentation  where four experimental models (chambers) were built using four dissimilar  compressed earth (C.E.B) configurations; compressed earth horizontal hollow brick  (C.E.H.H.B), compressed earth vertical hollow brick (C.E.V.H.B), compressed earth cellular brick  (C.E.C.B), and compressed earth solid  brick  (C.E.S.B) respectively, data were collected from fieldwork experimental chambers using two distinct wall surface temperature measuring devices; an onset UX120-M600 4-channel analogue data logger and Testo 835 Infrared thermometer which were utilized to measure the interior wall surface temperature facing the west direction of each experimental chamber to determine the rate of thermal admittance of the entire chambers built with distinct C.E.B configurations, the extracted data using surface temperature measuring instrument were analyzed using the spss software package for identification of the C.E.B configurations with the least thermal permeation from outdoor environment to indoor space of the school building via external walls of the building. After the statistical analysis, the study's outcome revealed that compressed earth horizontal hollow brick (C.E.H.H.B) has a minimum heat transfer rate of (34.933OC) and (35.7493OC), among other C.E.B configurations. This undoubtedly indicated the appropriate C.E.B configurations for school buildings in hot-dry climate regions of northwestern Nigeria.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
尼日利亚西北部干热气候地区学校建筑压缩土砖结构热导纳评价
通过建筑的外墙组件将热量渗透到学校建筑外壳中,导致许多后果,导致不健康的室内生活条件不利于教学和学习活动,这对学生的总体学习成绩和生产力产生负面影响,研究进行了实地实验,其中使用四种不同的压缩土(C.E.B)配置建立了四个实验模型(室);压缩土水平空心砖(C.E.H.H.B)、压缩土垂直空心砖(C.E.V.H.B)、压缩土蜂窝砖(C.E.C.B)和压缩土实心砖(C.E.S.B)分别采用两种不同的墙体表面温度测量装置在野外实验室内采集数据;UX120-M600 4通道模拟数据记录仪和Testo 835红外测温仪,用于测量每个实验室内面向西方向的内壁表面温度,以确定不同ceb配置的整个实验室内的热导纳率。利用表面温度测量仪提取的数据,利用spss软件包进行分析,确定室外环境经建筑外墙向教学楼室内空间热渗透最小的C.E.B配置。经统计分析,研究结果表明,压土水平空心砖(C.E.H.H.B)的最小换热率分别为(34.933OC)和(35.7493OC)。这无疑为尼日利亚西北部干热气候地区的学校建筑指明了合适的ceb配置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1