Broadband High-Resolution Stigmatic Spectral Imaging in the XUV Range

Pub Date : 2023-08-29 DOI:10.1007/s10946-023-10155-5
A. O. Kolesnikov, A. N. Shatokhin, E. A. Vishnyakov, E. N. Ragozin
{"title":"Broadband High-Resolution Stigmatic Spectral Imaging in the XUV Range","authors":"A. O. Kolesnikov,&nbsp;A. N. Shatokhin,&nbsp;E. A. Vishnyakov,&nbsp;E. N. Ragozin","doi":"10.1007/s10946-023-10155-5","DOIUrl":null,"url":null,"abstract":"<div><p>We describe the experimental implementation of high-resolution soft X-ray spectrographs, which are stigmatic throughout their operating range. The optical configuration comprises a grazing-incidence plane VLS grating and a broadband normal-incidence focusing mirror with an aperiodic multilayer coating structure. The operating range is defined by the aperiodic multilayer mirror in use (Mo/Si: 12.5 – 25 nm; Mo/Be: 11 – 14 nm). The spectral resolution is determined by CCD detector resolution and is numerically equal to the product of the plate scale and the double pixel size. Vertically spaceresolved laser-produced plasma spectra of multiply charged ions are presented. The spatial resolution is equal to about 26 μm, the double pixel size. We discuss the prospect of extending high-resolution stigmatic spectral imaging below 11 nm and outline the data of numerical calculations of broadband normal-incidence mirrors based on aperiodic Ru/Sr and La/B<sub>4</sub>C multilayer structures.</p></div>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s10946-023-10155-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We describe the experimental implementation of high-resolution soft X-ray spectrographs, which are stigmatic throughout their operating range. The optical configuration comprises a grazing-incidence plane VLS grating and a broadband normal-incidence focusing mirror with an aperiodic multilayer coating structure. The operating range is defined by the aperiodic multilayer mirror in use (Mo/Si: 12.5 – 25 nm; Mo/Be: 11 – 14 nm). The spectral resolution is determined by CCD detector resolution and is numerically equal to the product of the plate scale and the double pixel size. Vertically spaceresolved laser-produced plasma spectra of multiply charged ions are presented. The spatial resolution is equal to about 26 μm, the double pixel size. We discuss the prospect of extending high-resolution stigmatic spectral imaging below 11 nm and outline the data of numerical calculations of broadband normal-incidence mirrors based on aperiodic Ru/Sr and La/B4C multilayer structures.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
XUV波段的宽带高分辨率污名化光谱成像
我们描述了高分辨率软x射线光谱仪的实验实现,它在整个操作范围内都是耻辱的。光学结构包括掠入射平面VLS光栅和带非周期多层涂层结构的宽带正入射聚焦镜。工作范围由所使用的非周期多层反射镜定义(Mo/Si: 12.5 - 25 nm;Mo/Be: 11 - 14 nm)。光谱分辨率由CCD探测器分辨率决定,在数值上等于板尺与双像元尺寸的乘积。给出了垂直空间分辨激光产生的多电荷离子等离子体光谱。空间分辨率约为26 μm,是像素尺寸的两倍。我们讨论了在11 nm以下扩展高分辨率柱体光谱成像的前景,并概述了基于非周期Ru/Sr和La/B4C多层结构的宽带正入射反射镜的数值计算数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1