A. O. Kolesnikov, A. N. Shatokhin, E. A. Vishnyakov, E. N. Ragozin
{"title":"Broadband High-Resolution Stigmatic Spectral Imaging in the XUV Range","authors":"A. O. Kolesnikov, A. N. Shatokhin, E. A. Vishnyakov, E. N. Ragozin","doi":"10.1007/s10946-023-10155-5","DOIUrl":null,"url":null,"abstract":"<div><p>We describe the experimental implementation of high-resolution soft X-ray spectrographs, which are stigmatic throughout their operating range. The optical configuration comprises a grazing-incidence plane VLS grating and a broadband normal-incidence focusing mirror with an aperiodic multilayer coating structure. The operating range is defined by the aperiodic multilayer mirror in use (Mo/Si: 12.5 – 25 nm; Mo/Be: 11 – 14 nm). The spectral resolution is determined by CCD detector resolution and is numerically equal to the product of the plate scale and the double pixel size. Vertically spaceresolved laser-produced plasma spectra of multiply charged ions are presented. The spatial resolution is equal to about 26 μm, the double pixel size. We discuss the prospect of extending high-resolution stigmatic spectral imaging below 11 nm and outline the data of numerical calculations of broadband normal-incidence mirrors based on aperiodic Ru/Sr and La/B<sub>4</sub>C multilayer structures.</p></div>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s10946-023-10155-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
We describe the experimental implementation of high-resolution soft X-ray spectrographs, which are stigmatic throughout their operating range. The optical configuration comprises a grazing-incidence plane VLS grating and a broadband normal-incidence focusing mirror with an aperiodic multilayer coating structure. The operating range is defined by the aperiodic multilayer mirror in use (Mo/Si: 12.5 – 25 nm; Mo/Be: 11 – 14 nm). The spectral resolution is determined by CCD detector resolution and is numerically equal to the product of the plate scale and the double pixel size. Vertically spaceresolved laser-produced plasma spectra of multiply charged ions are presented. The spatial resolution is equal to about 26 μm, the double pixel size. We discuss the prospect of extending high-resolution stigmatic spectral imaging below 11 nm and outline the data of numerical calculations of broadband normal-incidence mirrors based on aperiodic Ru/Sr and La/B4C multilayer structures.