{"title":"Fault analysis and control of grounding power transformer","authors":"A. Meddeb, S. Chebbi","doi":"10.1504/IJSISE.2016.078265","DOIUrl":null,"url":null,"abstract":"Neutral grounding systems are a critical element in the power system reliability. Thus, a good choice of grounding modes has become a hot-button issue among the power supply. During a single-phase to ground fault, current flows from the transformer winding through the ground path and the neutral grounding system. The paper presents considerations on the problematic of the grounding system. The theoretical and simulations studies allowed the control of the neutral grounding to avoid the insulation deterioration or accidental grounds in the transformer winding and avoid the distribution of zero-sequence current. For that reason, the attention of research is moving to developing a mathematical model to study the impact of neutral grounding transformer, the fault resistance effect and the impact of the distance separating a fault point to the power generators. We performed case study IEEE-14 bus under MATLAB environment.","PeriodicalId":56359,"journal":{"name":"International Journal of Signal and Imaging Systems Engineering","volume":"9 1","pages":"268"},"PeriodicalIF":0.6000,"publicationDate":"2016-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1504/IJSISE.2016.078265","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Signal and Imaging Systems Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJSISE.2016.078265","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 3

Abstract

Neutral grounding systems are a critical element in the power system reliability. Thus, a good choice of grounding modes has become a hot-button issue among the power supply. During a single-phase to ground fault, current flows from the transformer winding through the ground path and the neutral grounding system. The paper presents considerations on the problematic of the grounding system. The theoretical and simulations studies allowed the control of the neutral grounding to avoid the insulation deterioration or accidental grounds in the transformer winding and avoid the distribution of zero-sequence current. For that reason, the attention of research is moving to developing a mathematical model to study the impact of neutral grounding transformer, the fault resistance effect and the impact of the distance separating a fault point to the power generators. We performed case study IEEE-14 bus under MATLAB environment.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电力变压器接地故障分析与控制
中性点接地系统是影响电力系统可靠性的关键因素。因此,如何选择良好的接地方式已成为电源领域的热点问题。在单相接地故障中,电流从变压器绕组流过接地路径和中性点接地系统。本文就接地系统问题提出了几点思考。通过理论和仿真研究,对中性点接地进行控制,避免变压器绕组绝缘劣化或意外接地,避免零序电流分布。因此,研究的重点转移到建立一个数学模型来研究中性点接地变压器的影响、故障电阻效应以及故障点间距对发电机的影响。在MATLAB环境下对IEEE-14总线进行了实例研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
0
期刊最新文献
Image correlation, non-uniformly sampled rotation displacement measurement estimation Computational simulation of human fovea Syntactic approach to reconstruct simple and complex medical images Computational simulation of human fovea Syntactic approach to reconstruct simple and complex medical images
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1