{"title":"Auto-connected transformer with 40° phase shifting for harmonic elimination","authors":"Arafet Ben Ammar, F. B. Ammar","doi":"10.1504/IJSISE.2016.078260","DOIUrl":null,"url":null,"abstract":"The conventional six-pulse and 12-pulse generate harmonics pollution in the network. In order to reduce the harmonics propagation has proposed the use of other structures that offer a greater flexibility to transit control of energy and a significant harmonics reduction. In this paper, the authors present the design, analysis and experimental set-up of a delta-connected autotransformer-based 18-pulse ac-dc converter with 40° phase shifting to decrease the harmonics pollution in the network side. The simulation results show that autotransformer configuration 18-pulse capable to suppress harmonics of the order less than 18th.n±1. This design gives a better THD current compared with the two configurations, six-pulse and 12-pulse. Moreover, a prototype of the proposed autotransformer-based 18-pulse ac-dc converter is developed and test results are presented to validate the developed design procedure and simulation models of this ac-dc converter.","PeriodicalId":56359,"journal":{"name":"International Journal of Signal and Imaging Systems Engineering","volume":"9 1","pages":"233"},"PeriodicalIF":0.6000,"publicationDate":"2016-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1504/IJSISE.2016.078260","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Signal and Imaging Systems Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJSISE.2016.078260","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
The conventional six-pulse and 12-pulse generate harmonics pollution in the network. In order to reduce the harmonics propagation has proposed the use of other structures that offer a greater flexibility to transit control of energy and a significant harmonics reduction. In this paper, the authors present the design, analysis and experimental set-up of a delta-connected autotransformer-based 18-pulse ac-dc converter with 40° phase shifting to decrease the harmonics pollution in the network side. The simulation results show that autotransformer configuration 18-pulse capable to suppress harmonics of the order less than 18th.n±1. This design gives a better THD current compared with the two configurations, six-pulse and 12-pulse. Moreover, a prototype of the proposed autotransformer-based 18-pulse ac-dc converter is developed and test results are presented to validate the developed design procedure and simulation models of this ac-dc converter.