Seismic load tests on exterior beam-column connections of existing RC structures

IF 1 4区 工程技术 Q4 ENGINEERING, CIVIL Gradevinar Pub Date : 2019-01-01 DOI:10.14256/jce.2524.2018
Turgay Çoşgun, Cumhur Cosgun, A. Kanishka, Atakan Mangır, B. Sayın, A. Türk
{"title":"Seismic load tests on exterior beam-column connections of existing RC structures","authors":"Turgay Çoşgun, Cumhur Cosgun, A. Kanishka, Atakan Mangır, B. Sayın, A. Türk","doi":"10.14256/jce.2524.2018","DOIUrl":null,"url":null,"abstract":"Recommendations for enhancement of performance of RC beam-column joints under seismic effects are presented in this study. The aim is to evaluate the use of lowstrength concrete with plain bars without stirrups in the joints. An additional aim is to study behaviour of joints in the aforementioned conditions under cyclic loading. Five specimens with various reinforcement configurations were produced and tested in the experimental process. Based on results obtained in the study, it is concluded that the stirrup arrangement in the joints, and the use of at least 90-degree hooks in longitudinal reinforcement of beams, are critical parameters for the performance of existing structures.","PeriodicalId":50415,"journal":{"name":"Gradevinar","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.14256/jce.2524.2018","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gradevinar","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.14256/jce.2524.2018","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 2

Abstract

Recommendations for enhancement of performance of RC beam-column joints under seismic effects are presented in this study. The aim is to evaluate the use of lowstrength concrete with plain bars without stirrups in the joints. An additional aim is to study behaviour of joints in the aforementioned conditions under cyclic loading. Five specimens with various reinforcement configurations were produced and tested in the experimental process. Based on results obtained in the study, it is concluded that the stirrup arrangement in the joints, and the use of at least 90-degree hooks in longitudinal reinforcement of beams, are critical parameters for the performance of existing structures.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
既有钢筋混凝土结构外梁柱连接的地震荷载试验
本文对钢筋混凝土梁柱节点在地震作用下的性能改进提出了建议。目的是评估低强度混凝土在接缝中使用无箍筋的素筋。另一个目的是研究上述条件下循环荷载作用下节点的行为。在试验过程中,制作了5个不同配筋配置的试件并进行了试验。基于研究结果,得出结论:节点中箍筋的布置以及梁纵向钢筋中至少90度吊钩的使用是现有结构性能的关键参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Gradevinar
Gradevinar ENGINEERING, CIVIL-
CiteScore
1.70
自引率
18.20%
发文量
56
审稿时长
6-12 weeks
期刊介绍: Information not localized
期刊最新文献
Quasi-static tests on RC building columns strengthened with CFRP Construction of a new day hospital in Zadar using recycled aggregate concrete Damage assessment of water supply networks due to seismic events using vulnerability functions Centrifugally-cast concrete poles with non-metallic reinforcement Overview of research on fire effects in RC elements and assessment of RC structures after fire
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1