Preliminary Study of an Objective Evaluation Method for Pulse Diagnosis using Radial Artery Pulse Measurement Device

IF 0.8 Q4 ENGINEERING, BIOMEDICAL Advanced Biomedical Engineering Pub Date : 2021-01-01 DOI:10.14326/abe.10.113
A. Yamada, Y. Inoue, Y. Shiraishi, T. Seki, T. Yambe
{"title":"Preliminary Study of an Objective Evaluation Method for Pulse Diagnosis using Radial Artery Pulse Measurement Device","authors":"A. Yamada, Y. Inoue, Y. Shiraishi, T. Seki, T. Yambe","doi":"10.14326/abe.10.113","DOIUrl":null,"url":null,"abstract":"In traditional Chinese pulse diagnosis, the pulses of bilateral radial arteries are palpated by three fingers. In this study, a device that can objectively perform pulse diagnosis using multiple pressure sensors with a cuff was developed. The device has three pressure sensors in series and a cuff to apply external pressure load. Pulse waves were measured using the non-invasive pulse diagnostic device. The relationship of the data obtained from the proposed system with the diagnosis by the traditional method was examined. The study was conducted with the approval of the Ethics Committee in Tohoku University. Twelve adult male subjects were studied. Data of pulse waveforms recorded from the pulse diagnosis device, electrocardiogram, and continuous blood pressure measured at the fingertip were stored and analyzed. The pulse waves of the subjects were cate-gorized as middle pulse, floating pulse, or sunken pulse according to pulse diagnosis in traditional Chinese medicine. Pulse–waveform data were obtained to measure the pulse–pressure changes, which showed different patterns of the rise time at the three measurement sites. Envelope analysis of the pulse waveform from the middle sensor revealed that the peak value of the pulse pressure increased during calculation stress compared to the resting state. It was possible to measure the pulse waves even when a higher external pressure was applied. Objective pulse-wave measurement using a method similar to that in traditional pulse diagnosis was realized, and pulse waveforms were measured using the proposed pulse diagnosis system.","PeriodicalId":54017,"journal":{"name":"Advanced Biomedical Engineering","volume":"1 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14326/abe.10.113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 2

Abstract

In traditional Chinese pulse diagnosis, the pulses of bilateral radial arteries are palpated by three fingers. In this study, a device that can objectively perform pulse diagnosis using multiple pressure sensors with a cuff was developed. The device has three pressure sensors in series and a cuff to apply external pressure load. Pulse waves were measured using the non-invasive pulse diagnostic device. The relationship of the data obtained from the proposed system with the diagnosis by the traditional method was examined. The study was conducted with the approval of the Ethics Committee in Tohoku University. Twelve adult male subjects were studied. Data of pulse waveforms recorded from the pulse diagnosis device, electrocardiogram, and continuous blood pressure measured at the fingertip were stored and analyzed. The pulse waves of the subjects were cate-gorized as middle pulse, floating pulse, or sunken pulse according to pulse diagnosis in traditional Chinese medicine. Pulse–waveform data were obtained to measure the pulse–pressure changes, which showed different patterns of the rise time at the three measurement sites. Envelope analysis of the pulse waveform from the middle sensor revealed that the peak value of the pulse pressure increased during calculation stress compared to the resting state. It was possible to measure the pulse waves even when a higher external pressure was applied. Objective pulse-wave measurement using a method similar to that in traditional pulse diagnosis was realized, and pulse waveforms were measured using the proposed pulse diagnosis system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
桡动脉脉搏测量仪对脉搏诊断客观评价方法的初步研究
在中医脉诊中,用三指触诊双侧桡动脉脉。在本研究中,开发了一种可以使用多个压力传感器和袖带客观地进行脉搏诊断的设备。该设备有三个串联的压力传感器和一个用于施加外部压力负载的袖带。采用无创脉搏诊断仪测量脉搏波。分析了系统数据与传统诊断方法的关系。这项研究是在东北大学伦理委员会的批准下进行的。研究对象为12名成年男性。存储并分析脉搏诊断仪记录的脉搏波形、心电图和指尖连续测量的血压数据。根据中医脉象诊断,将受试者的脉象分为中脉、浮脉、沉脉。通过获取脉冲波形数据来测量脉冲压力的变化,三个测点的脉冲压力上升时间呈现出不同的模式。中间传感器脉冲波形包络分析表明,计算应力时脉冲压力峰值较静息状态增大。即使施加较高的外部压力,也可以测量脉冲波。采用与传统脉冲诊断方法相似的方法实现了脉冲波形的客观测量,并利用所提出的脉冲诊断系统实现了脉冲波形的测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Advanced Biomedical Engineering
Advanced Biomedical Engineering ENGINEERING, BIOMEDICAL-
CiteScore
1.40
自引率
10.00%
发文量
15
审稿时长
15 weeks
期刊最新文献
SATORI: Amplification-free digital RNA detection method for the diagnosis of viral infections. Basic Investigation of the Effect of Insole Shape on Leg Skeletal Muscle Mass and Pressure Changes during Walking Investigating Mental Task Combination for Brain-Computer Interface Based on Brain State Discrimination Using Subjective Ratings Development of Beat Analysis Software for the Non-invasive Evaluation of Cardiac Constructs Fabricated with a Three-dimensional Bioprinter Transepidermal Water Loss Estimation Model for Evaluating Skin Barrier Function
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1