Efficient Detection of High-frequency Biomarker Signals of Epilepsy by a Transfer-learning-based Convolutional Neural Network

IF 0.8 Q4 ENGINEERING, BIOMEDICAL Advanced Biomedical Engineering Pub Date : 2021-01-01 DOI:10.14326/abe.10.158
Yukinobu Takayanagi, Y. Takayama, K. Iijima, M. Iwasaki, Y. Ono
{"title":"Efficient Detection of High-frequency Biomarker Signals of Epilepsy by a Transfer-learning-based Convolutional Neural Network","authors":"Yukinobu Takayanagi, Y. Takayama, K. Iijima, M. Iwasaki, Y. Ono","doi":"10.14326/abe.10.158","DOIUrl":null,"url":null,"abstract":"High-frequency oscillation (HFO) is an important electrophysiological biomarker for estimating the epileptogenic zone in patients with epilepsy, but its clinical use is limited due to the high false-positive detection rate associated with conventional auto-detection methods based on one-dimensional spectral energy features. The purpose of this study was to apply a convolutional neural network (CNN)-based classifier to the candidate signals detected using conventional methods, and to extract HFOs more accurately and automatically. We adopted an image-based CNN because HFOs exhibit a localized power distribution in both time and frequency, which is utilized for the visual inspection of HFOs. To reduce the number of training datasets required for one patient, we employed transfer learning of an existing natural image classifier or the CNN HFO-classifier of another patient. We applied the proposed methods to the electrocorticography data of two patients with focal epilepsy who underwent pre-surgical examination. When the natural image discriminator AlexNet was transfer-learned to the HFO classifier, an accuracy of 93.0 ± 0.997% was achieved using 3000 training datasets. The false discovery rate (FDR) of HFO was 78.0% at the completion of the conventional method, which was significantly improved to 19.0 ± 4.42% after applying the CNN-based HFO classifier. When the HFO classifier trained with one patient was further relearned using the training datasets of another patient, the accuracy of determining HFOs in the latter patient was consistently above 91.0% (maximum 93.3 ± 0.967%) with the incorporation of 200 or more training datasets. These results suggest that the proposed method may provide an accurate, automatic, and personalized HFO classifier while liberating neurologists from the time-consuming manual detection of HFO signals for diagnosis.","PeriodicalId":54017,"journal":{"name":"Advanced Biomedical Engineering","volume":"1 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14326/abe.10.158","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

High-frequency oscillation (HFO) is an important electrophysiological biomarker for estimating the epileptogenic zone in patients with epilepsy, but its clinical use is limited due to the high false-positive detection rate associated with conventional auto-detection methods based on one-dimensional spectral energy features. The purpose of this study was to apply a convolutional neural network (CNN)-based classifier to the candidate signals detected using conventional methods, and to extract HFOs more accurately and automatically. We adopted an image-based CNN because HFOs exhibit a localized power distribution in both time and frequency, which is utilized for the visual inspection of HFOs. To reduce the number of training datasets required for one patient, we employed transfer learning of an existing natural image classifier or the CNN HFO-classifier of another patient. We applied the proposed methods to the electrocorticography data of two patients with focal epilepsy who underwent pre-surgical examination. When the natural image discriminator AlexNet was transfer-learned to the HFO classifier, an accuracy of 93.0 ± 0.997% was achieved using 3000 training datasets. The false discovery rate (FDR) of HFO was 78.0% at the completion of the conventional method, which was significantly improved to 19.0 ± 4.42% after applying the CNN-based HFO classifier. When the HFO classifier trained with one patient was further relearned using the training datasets of another patient, the accuracy of determining HFOs in the latter patient was consistently above 91.0% (maximum 93.3 ± 0.967%) with the incorporation of 200 or more training datasets. These results suggest that the proposed method may provide an accurate, automatic, and personalized HFO classifier while liberating neurologists from the time-consuming manual detection of HFO signals for diagnosis.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于迁移学习的卷积神经网络高效检测癫痫高频生物标志物信号
高频振荡(HFO)是一种重要的电生理生物标志物,用于估计癫痫患者的癫痫区,但由于传统的基于一维光谱能量特征的自动检测方法存在较高的假阳性检出率,其临床应用受到限制。本研究的目的是将基于卷积神经网络(CNN)的分类器应用于传统方法检测到的候选信号,更准确、自动地提取hfo。我们采用了基于图像的CNN,因为hfo在时间和频率上都表现出局域化的功率分布,可以用于hfo的目视检测。为了减少一名患者所需的训练数据集数量,我们采用了现有自然图像分类器的迁移学习或另一名患者的CNN hfo分类器。我们将所提出的方法应用于2例局灶性癫痫患者术前检查的皮质电图数据。将自然图像鉴别器AlexNet移植到HFO分类器中,使用3000个训练数据集,准确率达到93.0±0.997%。在常规方法完成时,HFO的错误发现率(FDR)为78.0%,应用基于cnn的HFO分类器后,FDR显著提高至19.0±4.42%。当用一个患者训练过的HFO分类器使用另一个患者的训练数据集进一步重新学习时,当纳入200个或更多的训练数据集时,后者的HFO识别准确率始终在91.0%以上(最高93.3±0.967%)。这些结果表明,所提出的方法可以提供准确、自动和个性化的HFO分类器,同时将神经科医生从耗时的人工检测HFO信号中解放出来。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Advanced Biomedical Engineering
Advanced Biomedical Engineering ENGINEERING, BIOMEDICAL-
CiteScore
1.40
自引率
10.00%
发文量
15
审稿时长
15 weeks
期刊最新文献
SATORI: Amplification-free digital RNA detection method for the diagnosis of viral infections. Basic Investigation of the Effect of Insole Shape on Leg Skeletal Muscle Mass and Pressure Changes during Walking Investigating Mental Task Combination for Brain-Computer Interface Based on Brain State Discrimination Using Subjective Ratings Development of Beat Analysis Software for the Non-invasive Evaluation of Cardiac Constructs Fabricated with a Three-dimensional Bioprinter Transepidermal Water Loss Estimation Model for Evaluating Skin Barrier Function
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1