Comparative characterization of quantitative gas chromatographic analysis capabilities using basic and modified external standard methods

Q4 Chemistry Analitika i Kontrol Pub Date : 2019-01-01 DOI:10.15826/ANALITIKA.2019.23.2.007
I. Zenkevich, Natalia A. Devleshova, Yulia V. Krivolapova, D. Moskvichev, Lyubov G. Rubicheva, Nikolai Yu. Tyuftyakov
{"title":"Comparative characterization of quantitative gas chromatographic analysis capabilities using basic and modified external standard methods","authors":"I. Zenkevich, Natalia A. Devleshova, Yulia V. Krivolapova, D. Moskvichev, Lyubov G. Rubicheva, Nikolai Yu. Tyuftyakov","doi":"10.15826/ANALITIKA.2019.23.2.007","DOIUrl":null,"url":null,"abstract":"The known mode of chromatographic quantification by the method of external standard is based on the comparison of average absolute peak areas of analyte(s) for target samp les ( S x ) and additionally prepared external standards ( S stand ). This method is characteri zed by the valuable “sensitivity” of the results in relation to the repeatability of the measured peak areas. In the modified method of external standard, the equal amounts of additional standard are added to the equal amounts of samples; the peak ratios ( S x / S add.stand ) and ( S stand / S add.stand ) are used in the subsequent data processing. This modified external standard method is not described in the contemporary scien tific and teaching literature on gas chromatography. Thus, for the illustration of its advan tages, the results of target analyte quantification in different solvents using basic and modified methods are compa red in the cur rent study. All measurements were carried out by the senior students of the Institute for Chemistry of St. Petersburg State University (Russia) during their practical exercises in gas chromatography. It was shown that the modified external standard method compared with its basic ver sion provided better repeatability of determinations, better precision (lesser systema tic errors) and reduced the overall time expenses due to the lesser quantity of serial ana lyses and the absence of the necessity to reveal and exclude the outliers.","PeriodicalId":37743,"journal":{"name":"Analitika i Kontrol","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analitika i Kontrol","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15826/ANALITIKA.2019.23.2.007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 1

Abstract

The known mode of chromatographic quantification by the method of external standard is based on the comparison of average absolute peak areas of analyte(s) for target samp les ( S x ) and additionally prepared external standards ( S stand ). This method is characteri zed by the valuable “sensitivity” of the results in relation to the repeatability of the measured peak areas. In the modified method of external standard, the equal amounts of additional standard are added to the equal amounts of samples; the peak ratios ( S x / S add.stand ) and ( S stand / S add.stand ) are used in the subsequent data processing. This modified external standard method is not described in the contemporary scien tific and teaching literature on gas chromatography. Thus, for the illustration of its advan tages, the results of target analyte quantification in different solvents using basic and modified methods are compa red in the cur rent study. All measurements were carried out by the senior students of the Institute for Chemistry of St. Petersburg State University (Russia) during their practical exercises in gas chromatography. It was shown that the modified external standard method compared with its basic ver sion provided better repeatability of determinations, better precision (lesser systema tic errors) and reduced the overall time expenses due to the lesser quantity of serial ana lyses and the absence of the necessity to reveal and exclude the outliers.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用基本和改进的外部标准方法的定量气相色谱分析能力的比较特性
已知的外标法色谱定量方法是将目标样品(sx)的分析物(s)的平均绝对峰面积与另外制备的外标(s stand)进行比较。该方法的特点是与测量峰面积的可重复性有关的结果的有价值的“灵敏度”。外标法是在等量的样品中加入等量的附加标准品;在随后的数据处理中使用峰值比(S x / S add.stand)和(S stand / S add.stand)。这种改进的外标法在当代气相色谱的科学和教学文献中没有描述。因此,为了说明其优势,本研究比较了基本方法和改进方法在不同溶剂中对目标分析物的定量结果。所有的测量都是由俄罗斯圣彼得堡国立大学化学研究所的高年级学生在气相色谱的实践练习中进行的。结果表明,改进后的外标法与基本法相比,具有更好的重复性和精密度(更小的系统误差),由于序列分析的数量较少,不需要发现和排除异常值,从而减少了总体时间花费。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analitika i Kontrol
Analitika i Kontrol Chemistry-Analytical Chemistry
CiteScore
0.90
自引率
0.00%
发文量
15
期刊介绍: Analitika i Kontrol is a scientific journal covering theoretical and applied aspects of analytical chemistry and analytical control, published since autumn 1997. Founder and publisher of the journal is the Ural Federal University named after the first President of Russia Boris Yeltsin (UrFU, Ekaterinburg).
期刊最新文献
Electrophoretic determination of carboxylic acids in blood serum with intracapillary concentration Fluorescence of anisotropic primary X-ray radiation Selection of the parameters of a multicapillary column for portable gas analyzers by Kovach indices Differentiation of oil samples by isomeric composition of paraffins using cluster analysis methods Important features of retention indices determination in reversed-phase high performance liquid chromatography
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1