I. Zenkevich, Natalia A. Devleshova, Yulia V. Krivolapova, D. Moskvichev, Lyubov G. Rubicheva, Nikolai Yu. Tyuftyakov
{"title":"Comparative characterization of quantitative gas chromatographic analysis capabilities using basic and modified external standard methods","authors":"I. Zenkevich, Natalia A. Devleshova, Yulia V. Krivolapova, D. Moskvichev, Lyubov G. Rubicheva, Nikolai Yu. Tyuftyakov","doi":"10.15826/ANALITIKA.2019.23.2.007","DOIUrl":null,"url":null,"abstract":"The known mode of chromatographic quantification by the method of external standard is based on the comparison of average absolute peak areas of analyte(s) for target samp les ( S x ) and additionally prepared external standards ( S stand ). This method is characteri zed by the valuable “sensitivity” of the results in relation to the repeatability of the measured peak areas. In the modified method of external standard, the equal amounts of additional standard are added to the equal amounts of samples; the peak ratios ( S x / S add.stand ) and ( S stand / S add.stand ) are used in the subsequent data processing. This modified external standard method is not described in the contemporary scien tific and teaching literature on gas chromatography. Thus, for the illustration of its advan tages, the results of target analyte quantification in different solvents using basic and modified methods are compa red in the cur rent study. All measurements were carried out by the senior students of the Institute for Chemistry of St. Petersburg State University (Russia) during their practical exercises in gas chromatography. It was shown that the modified external standard method compared with its basic ver sion provided better repeatability of determinations, better precision (lesser systema tic errors) and reduced the overall time expenses due to the lesser quantity of serial ana lyses and the absence of the necessity to reveal and exclude the outliers.","PeriodicalId":37743,"journal":{"name":"Analitika i Kontrol","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analitika i Kontrol","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15826/ANALITIKA.2019.23.2.007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 1
Abstract
The known mode of chromatographic quantification by the method of external standard is based on the comparison of average absolute peak areas of analyte(s) for target samp les ( S x ) and additionally prepared external standards ( S stand ). This method is characteri zed by the valuable “sensitivity” of the results in relation to the repeatability of the measured peak areas. In the modified method of external standard, the equal amounts of additional standard are added to the equal amounts of samples; the peak ratios ( S x / S add.stand ) and ( S stand / S add.stand ) are used in the subsequent data processing. This modified external standard method is not described in the contemporary scien tific and teaching literature on gas chromatography. Thus, for the illustration of its advan tages, the results of target analyte quantification in different solvents using basic and modified methods are compa red in the cur rent study. All measurements were carried out by the senior students of the Institute for Chemistry of St. Petersburg State University (Russia) during their practical exercises in gas chromatography. It was shown that the modified external standard method compared with its basic ver sion provided better repeatability of determinations, better precision (lesser systema tic errors) and reduced the overall time expenses due to the lesser quantity of serial ana lyses and the absence of the necessity to reveal and exclude the outliers.
已知的外标法色谱定量方法是将目标样品(sx)的分析物(s)的平均绝对峰面积与另外制备的外标(s stand)进行比较。该方法的特点是与测量峰面积的可重复性有关的结果的有价值的“灵敏度”。外标法是在等量的样品中加入等量的附加标准品;在随后的数据处理中使用峰值比(S x / S add.stand)和(S stand / S add.stand)。这种改进的外标法在当代气相色谱的科学和教学文献中没有描述。因此,为了说明其优势,本研究比较了基本方法和改进方法在不同溶剂中对目标分析物的定量结果。所有的测量都是由俄罗斯圣彼得堡国立大学化学研究所的高年级学生在气相色谱的实践练习中进行的。结果表明,改进后的外标法与基本法相比,具有更好的重复性和精密度(更小的系统误差),由于序列分析的数量较少,不需要发现和排除异常值,从而减少了总体时间花费。
期刊介绍:
Analitika i Kontrol is a scientific journal covering theoretical and applied aspects of analytical chemistry and analytical control, published since autumn 1997. Founder and publisher of the journal is the Ural Federal University named after the first President of Russia Boris Yeltsin (UrFU, Ekaterinburg).