Caffeine determination in beverages by voltammetry with the carbon-containing electrodes modified with aryldiazonium salts

Q4 Chemistry Analitika i Kontrol Pub Date : 2020-01-01 DOI:10.15826/analitika.2020.24.1.007
E. Dorozhko, A. O. Gusar, E. A. Bedareva, G. Slepchenko, M. Trusova, E. Korotkova
{"title":"Caffeine determination in beverages by voltammetry with the carbon-containing electrodes modified with aryldiazonium salts","authors":"E. Dorozhko, A. O. Gusar, E. A. Bedareva, G. Slepchenko, M. Trusova, E. Korotkova","doi":"10.15826/analitika.2020.24.1.007","DOIUrl":null,"url":null,"abstract":"The method of carbon containing electrode ( CCE ) modification with tosylated arendiazonium salts ( ADT ) was proposed for the voltammetric ( VA ) determination of caffeine in beverages. The comparison of chemical spontaneous and electrochemical modification approaches was carried out for ADT modified CCE for VA caffeine determination for the first time. A new class of ADT is characterized by high solubility and stability for one month that plays significant role in the process of electrode surface modification. Salts with nitro and carboxy substituents were tested. The optimal conditions for the spontaneous chemical modification of the CCE were selected: ADT modifier with NO 2 substituent, electrode immersion time in the modifier solution for 10 seconds, modifier concentration of 5 mg / dm 3 . ADT deposition on the electrode surface was confirmed by the IR spectroscopy and scanning electron microscopy with the formation of covalent bonds between the carbon atoms of electrode surface and the benzene rings of the modifier. It was shown that the electroactive surface area increases by two times after the modification. Consequently, the technique sensitivity increasing the detection limit of 51 mg / dm 3 and linear range extension from 154 up to 500 mg / dm 3 was observed. While applying the modified electrode, the analysis time was reduced to 15 minutes. Furthermore, the suitability of CCE modified with NO 2 substituent was tested for the analytical purposes. As a result, the caffeine was determined in some tonic and carbonated drinks. The comparison of the results obtained by the proposed method with ADT modified CCE and the level declared by the manufacturer was carried out. The high compliance was established. In addition, the obtained data was consistent with the results by the independent spectrophotometric method.","PeriodicalId":37743,"journal":{"name":"Analitika i Kontrol","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analitika i Kontrol","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15826/analitika.2020.24.1.007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 0

Abstract

The method of carbon containing electrode ( CCE ) modification with tosylated arendiazonium salts ( ADT ) was proposed for the voltammetric ( VA ) determination of caffeine in beverages. The comparison of chemical spontaneous and electrochemical modification approaches was carried out for ADT modified CCE for VA caffeine determination for the first time. A new class of ADT is characterized by high solubility and stability for one month that plays significant role in the process of electrode surface modification. Salts with nitro and carboxy substituents were tested. The optimal conditions for the spontaneous chemical modification of the CCE were selected: ADT modifier with NO 2 substituent, electrode immersion time in the modifier solution for 10 seconds, modifier concentration of 5 mg / dm 3 . ADT deposition on the electrode surface was confirmed by the IR spectroscopy and scanning electron microscopy with the formation of covalent bonds between the carbon atoms of electrode surface and the benzene rings of the modifier. It was shown that the electroactive surface area increases by two times after the modification. Consequently, the technique sensitivity increasing the detection limit of 51 mg / dm 3 and linear range extension from 154 up to 500 mg / dm 3 was observed. While applying the modified electrode, the analysis time was reduced to 15 minutes. Furthermore, the suitability of CCE modified with NO 2 substituent was tested for the analytical purposes. As a result, the caffeine was determined in some tonic and carbonated drinks. The comparison of the results obtained by the proposed method with ADT modified CCE and the level declared by the manufacturer was carried out. The high compliance was established. In addition, the obtained data was consistent with the results by the independent spectrophotometric method.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
芳基重氮盐修饰的含碳电极伏安法测定饮料中的咖啡因
建立了邻基化arendiazonium盐(ADT)修饰的含碳电极(CCE)伏安法测定饮料中咖啡因的方法。首次对ADT修饰的CCE进行了化学自发法和电化学修饰法的比较。一类新型ADT具有高溶解度和一个月的稳定性,在电极表面修饰过程中起着重要的作用。对硝基和羧基取代盐进行了测试。选择了CCE自发化学改性的最佳条件:含NO 2取代基的ADT改性剂,电极在改性剂溶液中浸泡时间为10 s,改性剂浓度为5 mg / dm 3。红外光谱和扫描电镜证实ADT在电极表面沉积,电极表面碳原子与改性剂苯环之间形成共价键。结果表明,改性后的电活性表面积增加了2倍。结果表明,该方法灵敏度提高,检出限为51 mg / dm,检测范围从154 ~ 500 mg / dm呈线性扩展。使用修饰电极时,分析时间缩短至15分钟。此外,还测试了二氧化氮取代基改性CCE的适用性。结果,在一些奎宁和碳酸饮料中测出了咖啡因。将所提出的方法与ADT修正CCE的结果与生产厂家声明的水平进行了比较。建立了高依从性。所得数据与独立分光光度法测定结果一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analitika i Kontrol
Analitika i Kontrol Chemistry-Analytical Chemistry
CiteScore
0.90
自引率
0.00%
发文量
15
期刊介绍: Analitika i Kontrol is a scientific journal covering theoretical and applied aspects of analytical chemistry and analytical control, published since autumn 1997. Founder and publisher of the journal is the Ural Federal University named after the first President of Russia Boris Yeltsin (UrFU, Ekaterinburg).
期刊最新文献
Electrophoretic determination of carboxylic acids in blood serum with intracapillary concentration Fluorescence of anisotropic primary X-ray radiation Selection of the parameters of a multicapillary column for portable gas analyzers by Kovach indices Differentiation of oil samples by isomeric composition of paraffins using cluster analysis methods Important features of retention indices determination in reversed-phase high performance liquid chromatography
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1