Portable rainfall simulator: evaluation and suitability of plot geometry to improve rainfall uniformity

IF 0.4 4区 环境科学与生态学 Q4 WATER RESOURCES Engenharia Sanitaria E Ambiental Pub Date : 2023-04-03 DOI:10.1590/s1413-415220220198
Antônio Reynaldo de Sousa Costa, L. A. Alvarenga, M. Thebaldi, P. A. Melo, A. Colombo, J. Isidoro
{"title":"Portable rainfall simulator: evaluation and suitability of plot geometry to improve rainfall uniformity","authors":"Antônio Reynaldo de Sousa Costa, L. A. Alvarenga, M. Thebaldi, P. A. Melo, A. Colombo, J. Isidoro","doi":"10.1590/s1413-415220220198","DOIUrl":null,"url":null,"abstract":"ABSTRACT Rainfall simulators are an important tool in many areas of geosciences. The authors of most of the studies published with rainfall simulators try to get the most uniform distribution of precipitation as possible. However, since this is very difficult, indexes are used to assess the greater or lesser uniformity of precipitation in the plot area under study. One of the most used indexes is the Christiansen uniformity coefficient. In this work, changes in the geometry of the wetted area of the plot were analyzed to improve the uniformity of precipitation. This was evaluated through the intensity of precipitation and Christiansen uniformity coefficient in the wet area. The tests were carried out using two models of spray nozzles and different operating pressures. The initial plot geometry was 0.7 x 1.0 m (0.7 m2). The Christiansen uniformity coefficient results were classified as low, while the best performance in terms of precipitation uniformity was obtained at a pressure of 48.3 kPa. Non-uniform precipitation was observable near the outer limits of the plot. Based on the best Christiansen uniformity coefficient results, it was proposed to reduce the effective area of the experimental plot from 0.70 to 0.56 m2, leading to a precipitation intensity of 114.07 and 149.20 mm·h−1, and a Christiansen uniformity coefficient of 81.6 and 83.8%, with the two models of spray nozzles. The results showed that adjusting the geometry of the plot can lead, in a simple and fast way, to a better uniformity of artificial rainfall.","PeriodicalId":11619,"journal":{"name":"Engenharia Sanitaria E Ambiental","volume":"1 1","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2023-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engenharia Sanitaria E Ambiental","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1590/s1413-415220220198","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"WATER RESOURCES","Score":null,"Total":0}
引用次数: 0

Abstract

ABSTRACT Rainfall simulators are an important tool in many areas of geosciences. The authors of most of the studies published with rainfall simulators try to get the most uniform distribution of precipitation as possible. However, since this is very difficult, indexes are used to assess the greater or lesser uniformity of precipitation in the plot area under study. One of the most used indexes is the Christiansen uniformity coefficient. In this work, changes in the geometry of the wetted area of the plot were analyzed to improve the uniformity of precipitation. This was evaluated through the intensity of precipitation and Christiansen uniformity coefficient in the wet area. The tests were carried out using two models of spray nozzles and different operating pressures. The initial plot geometry was 0.7 x 1.0 m (0.7 m2). The Christiansen uniformity coefficient results were classified as low, while the best performance in terms of precipitation uniformity was obtained at a pressure of 48.3 kPa. Non-uniform precipitation was observable near the outer limits of the plot. Based on the best Christiansen uniformity coefficient results, it was proposed to reduce the effective area of the experimental plot from 0.70 to 0.56 m2, leading to a precipitation intensity of 114.07 and 149.20 mm·h−1, and a Christiansen uniformity coefficient of 81.6 and 83.8%, with the two models of spray nozzles. The results showed that adjusting the geometry of the plot can lead, in a simple and fast way, to a better uniformity of artificial rainfall.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
便携式降雨模拟器:评估和适宜的地块几何,以提高降雨均匀性
降雨模拟器是地球科学许多领域的重要工具。大多数使用降雨模拟器发表的研究的作者都试图获得尽可能均匀的降水分布。然而,由于这是非常困难的,因此使用指数来评估研究地块内降水均匀性的大小。最常用的指标之一是克里斯蒂安森均匀系数。在这项工作中,分析了地块湿区几何形状的变化,以改善降水的均匀性。这是通过降水强度和湿区Christiansen均匀系数来评价的。试验采用了两种型号的喷嘴和不同的工作压力。最初的地块几何尺寸为0.7 x 1.0 m (0.7 m2)。在降水均匀性方面,在48.3 kPa压力下表现最佳,christensen均匀性系数较低。在小区外边界附近可观测到不均匀降水。根据最佳Christiansen均匀系数结果,提出将试验田有效面积从0.70 m2减小到0.56 m2,两种喷头的降水强度分别为114.07和149.20 mm·h−1,Christiansen均匀系数分别为81.6和83.8%。结果表明,调整地块的几何形状可以简单、快速地提高人工降雨的均匀性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.90
自引率
20.00%
发文量
101
审稿时长
>12 weeks
期刊介绍: Information not localized
期刊最新文献
Treatment and resource utilization for a non-biodegradable organophosphorus wastewater using micro-channel reactor Hydraulic behavior of valves used in building water supply systems Cost-benefit analysis of technological changes: case of a management solid waste consortia in the metropolitan region of Curitiba, Brazil Caracterização física de 14 bacias hidrográficas brasileiras: proposição do indicador da declividade média dos rios e do coeficiente de suscetibilidade de enchentes Proposição e análise de viabilidade econômica de cenários para o gerenciamento de resíduos da construção civil por meio de consórcios intermunicipais
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1