Hayat E.L.Ouafy, T. E. Ouafy, M. Oubenali, M. Mbarki, M. Echajia
{"title":"Evaluation Of Carbon Paste Electrode Modified With Heavy Metals For The Analysis Of Paracetamol By Voltammetry And Impedance Spectroscopy","authors":"Hayat E.L.Ouafy, T. E. Ouafy, M. Oubenali, M. Mbarki, M. Echajia","doi":"10.17721/moca.2020.93-99","DOIUrl":null,"url":null,"abstract":"The present document reports on the electrocatalytic activity of heavy metals (Copper(II), Nickel(II), Manganese(II) and Lead(II)) modified carbon paste electrodes (HM/CPE) for the paracetamol (Pr) oxidation where its results are compared with carbon paste electrode. The voltammetric behavior of Pr is explored where a sensitive anodic peak has appeared at about 0.27 V (vs. Ag/AgCl/3 M KCl) in 0.1 M Na2SO4 (pH 12). This peak results from the irreversible oxidation of Pr at HM/CPE surface. The catalytic effect was evaluated using cyclic and square wave voltammetry. Electrochemical impedance spectroscopy also confirms our experimental results as the HM/CPE shows the least charge transfer resistance. Also, HM/ CPE can be utilized successfully to ameliorate the electroanalysis of Pr at very weak concentration with excellent sensitivity. The calibration curves were linear from 6.0 · 10-5 to 8.0 · 10-4 mol L-1. The detection limits were found approaching 10-9 mol L-1. Then, the proposed method was applied to detect Pr in river water samples with satisfactory results.","PeriodicalId":18626,"journal":{"name":"Methods and Objects of Chemical Analysis","volume":"1 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and Objects of Chemical Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17721/moca.2020.93-99","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 3
Abstract
The present document reports on the electrocatalytic activity of heavy metals (Copper(II), Nickel(II), Manganese(II) and Lead(II)) modified carbon paste electrodes (HM/CPE) for the paracetamol (Pr) oxidation where its results are compared with carbon paste electrode. The voltammetric behavior of Pr is explored where a sensitive anodic peak has appeared at about 0.27 V (vs. Ag/AgCl/3 M KCl) in 0.1 M Na2SO4 (pH 12). This peak results from the irreversible oxidation of Pr at HM/CPE surface. The catalytic effect was evaluated using cyclic and square wave voltammetry. Electrochemical impedance spectroscopy also confirms our experimental results as the HM/CPE shows the least charge transfer resistance. Also, HM/ CPE can be utilized successfully to ameliorate the electroanalysis of Pr at very weak concentration with excellent sensitivity. The calibration curves were linear from 6.0 · 10-5 to 8.0 · 10-4 mol L-1. The detection limits were found approaching 10-9 mol L-1. Then, the proposed method was applied to detect Pr in river water samples with satisfactory results.
期刊介绍:
The journal "Methods and objects of chemical analysis" is peer-review journal and publishes original articles of theoretical and experimental analysis on topical issues and bio-analytical chemistry, chemical and pharmaceutical analysis, as well as chemical metrology. Submitted works shall cover the results of completed studies and shall make scientific contributions to the relevant area of expertise. The journal publishes review articles, research articles and articles related to latest developments of analytical instrumentations.