CLINICAL AND RADIOLOGICAL OUTCOMES OF THE NEUROMUSCULAR SCOLIOSIS TREATMENT WITH S2-ALAR-ILIAC SCREW BY INTRAOPERATIVE NAVIGATION

Q4 Medicine Coluna/ Columna Pub Date : 2022-01-01 DOI:10.1590/s1808-185120222103264716
Alex Oliveira de Araújo, C. N. C. Segundo, R. Gepp, C. R. Gomes
{"title":"CLINICAL AND RADIOLOGICAL OUTCOMES OF THE NEUROMUSCULAR SCOLIOSIS TREATMENT WITH S2-ALAR-ILIAC SCREW BY INTRAOPERATIVE NAVIGATION","authors":"Alex Oliveira de Araújo, C. N. C. Segundo, R. Gepp, C. R. Gomes","doi":"10.1590/s1808-185120222103264716","DOIUrl":null,"url":null,"abstract":"ABSTRACT Objective: Analyze the clinical and radiological aspects of the S2AI screw technique in patients with neuromuscular scoliosis undergoing deformity correction surgery by intraoperative navigation. Methods: Retrospective analysis of medical records of patients undergoing neuromuscular scoliosis correction surgery with the S2-alar-iliac technique between 2017-2020. Results: In the total sample of 35 patients, 18 (51.4%) were female, with an average age of 14.9. The average preoperative coronal curve was 100° ± 26.2, with an average correction of 55% ± 16.3, with an average coronal curve of 44.8°± 19.5 at the end of surgery and 45 ° ± 19.6 at the end of follow-up. The average preoperative pelvic obliquity was 27.9°± 10.9, with a correction rate of 66.1% ± 27.6, being 8.2° ± 5.4 at the end of surgery and 9 .4°± 7.0 at the end of the follow-up. The average of operated levels was 17.3± 0.7. All 70 S2 screws had a diameter of 7mm. The average duration of surgeries was 416 ± 86 minutes, with estimated intraoperative bleeding of 921 ± 394.1 ml. The average density of screws in the sample was 1.3 ± 0.2 screws per level, and the average density in the lumbosacral spine was 1.5 ± 0.2. Conclusions: Intraoperative navigation can contribute to the rate of complications related to the S2AI screw decrease; in addition, the length of this screw appears to have significant relevance in maintaining the correction throughout the follow-up. Level of evidence IV; Case series.","PeriodicalId":40025,"journal":{"name":"Coluna/ Columna","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Coluna/ Columna","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/s1808-185120222103264716","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

ABSTRACT Objective: Analyze the clinical and radiological aspects of the S2AI screw technique in patients with neuromuscular scoliosis undergoing deformity correction surgery by intraoperative navigation. Methods: Retrospective analysis of medical records of patients undergoing neuromuscular scoliosis correction surgery with the S2-alar-iliac technique between 2017-2020. Results: In the total sample of 35 patients, 18 (51.4%) were female, with an average age of 14.9. The average preoperative coronal curve was 100° ± 26.2, with an average correction of 55% ± 16.3, with an average coronal curve of 44.8°± 19.5 at the end of surgery and 45 ° ± 19.6 at the end of follow-up. The average preoperative pelvic obliquity was 27.9°± 10.9, with a correction rate of 66.1% ± 27.6, being 8.2° ± 5.4 at the end of surgery and 9 .4°± 7.0 at the end of the follow-up. The average of operated levels was 17.3± 0.7. All 70 S2 screws had a diameter of 7mm. The average duration of surgeries was 416 ± 86 minutes, with estimated intraoperative bleeding of 921 ± 394.1 ml. The average density of screws in the sample was 1.3 ± 0.2 screws per level, and the average density in the lumbosacral spine was 1.5 ± 0.2. Conclusions: Intraoperative navigation can contribute to the rate of complications related to the S2AI screw decrease; in addition, the length of this screw appears to have significant relevance in maintaining the correction throughout the follow-up. Level of evidence IV; Case series.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
术中导航骶髂椎弓根螺钉治疗神经肌肉性脊柱侧凸的临床及影像学观察
【摘要】目的:分析S2AI螺钉技术在行术中导航矫形术的神经肌肉型脊柱侧凸患者中的临床及影像学表现。方法:回顾性分析2017-2020年采用骶髂侧翼技术行神经肌肉型脊柱侧凸矫正手术患者的病历。结果:35例患者中,女性18例(51.4%),平均年龄14.9岁。术前冠状曲线平均为100°±26.2,平均矫正率为55%±16.3,手术结束时冠状曲线平均为44.8°±19.5,随访结束时冠状曲线平均为45°±19.6。术前平均骨盆倾斜度为27.9°±10.9,矫正率为66.1%±27.6,手术结束时为8.2°±5.4,随访结束时为9.4°±7.0。手术水平平均值为17.3±0.7。70颗S2螺钉直径均为7mm。平均手术时间416±86分钟,估计术中出血921±394.1 ml。样本中平均螺钉密度为每节1.3±0.2颗,腰骶棘平均密度为1.5±0.2颗。结论:术中导航可降低S2AI螺钉相关并发症的发生率;此外,在整个随访过程中,螺钉的长度似乎与维持矫正有重要关系。证据等级IV;病例系列。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Coluna/ Columna
Coluna/ Columna Medicine-Surgery
CiteScore
0.40
自引率
0.00%
发文量
32
审稿时长
10 weeks
期刊最新文献
ADOLESCENT IDIOPATHIC SCOLIOSIS: PROGRESSION OF UNTREATED CASES FUNCTIONALITY OF INDIVIDUALS WITH LOW BACK PAIN: CROSS-SECTIONAL STUDY WITH ICF CORE SET ANESTHETIC BLOCK OF THE INTERTRANSVERSE SEPTUM, A PROSPECTIVE OBSERVATIONAL STUDY LUMBAR LORDOSIS VARIATION ACCORDING THE TYPE OF POSITIONER USED IN LUMBAR ARTHRODESIS CLINICAL PHOTOGRAPHIC AND RADIOLOGICAL CORRELATION IN PATIENTS WITH SCOLIOSIS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1