A study of TLCD parameters for structural vibration mitigation

IF 1.4 4区 工程技术 Q3 ENGINEERING, CIVIL Latin American Journal of Solids and Structures Pub Date : 2023-02-13 DOI:10.1590/1679-78257412
Maurício Vitali Mendes, Lucas Borchardt Ghedini, Rafael Neponuceno Batista, L. Pedroso
{"title":"A study of TLCD parameters for structural vibration mitigation","authors":"Maurício Vitali Mendes, Lucas Borchardt Ghedini, Rafael Neponuceno Batista, L. Pedroso","doi":"10.1590/1679-78257412","DOIUrl":null,"url":null,"abstract":"In this article, the efficiency of the tuned liquid column damper (TLCD) in reducing structural vibration is analyzed. The analysis by numerical methods and by analytical methods is adopted in the search for the ideal parameters for the liquid column. The equivalent linear model is considered for the U-shaped liquid column equation of motion with damping resulting from an orifice. Thus, variation of TLCD parameters for different loads is investigated. Initially, for the numerical study in conjunction with the analytical formulation, a sinusoidal forcing is adopted. Subsequently, the action of an earthquake through the recorded ground accelerations is considered in the case study. Optimal TLCD parameters are presented via response map for reducing the structure's maximum permanent response to harmonic excitation and for reducing the structure's rms response to seismic excitation with wide frequency and various amplitude. The variation of the TLCD parameters presented by the response map is directly related to the force acting on the structure. However, it is verified that regardless of the acting force, there is an ideal frequency range to tune the TLCD where the greatest reductions in the primary system response are found. It appears that reducing the aspect ratio of the liquid column makes this range narrower, making the damper more sensitive to parameter variations, as well as its performance. It is also observed that the increase in the attenuator mass ratio combined with the correct tuning and damping ratios present greater reductions in structural vibration. Also, the frequency ratio is reduced with the increase of the mass ratio, while the damping rate of the liquid column increases. From the ideal liquid column parameters determined by the parametric analysis, structural response reductions of approximately 60% were achieved.","PeriodicalId":18192,"journal":{"name":"Latin American Journal of Solids and Structures","volume":"1 1","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2023-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Latin American Journal of Solids and Structures","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1590/1679-78257412","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

In this article, the efficiency of the tuned liquid column damper (TLCD) in reducing structural vibration is analyzed. The analysis by numerical methods and by analytical methods is adopted in the search for the ideal parameters for the liquid column. The equivalent linear model is considered for the U-shaped liquid column equation of motion with damping resulting from an orifice. Thus, variation of TLCD parameters for different loads is investigated. Initially, for the numerical study in conjunction with the analytical formulation, a sinusoidal forcing is adopted. Subsequently, the action of an earthquake through the recorded ground accelerations is considered in the case study. Optimal TLCD parameters are presented via response map for reducing the structure's maximum permanent response to harmonic excitation and for reducing the structure's rms response to seismic excitation with wide frequency and various amplitude. The variation of the TLCD parameters presented by the response map is directly related to the force acting on the structure. However, it is verified that regardless of the acting force, there is an ideal frequency range to tune the TLCD where the greatest reductions in the primary system response are found. It appears that reducing the aspect ratio of the liquid column makes this range narrower, making the damper more sensitive to parameter variations, as well as its performance. It is also observed that the increase in the attenuator mass ratio combined with the correct tuning and damping ratios present greater reductions in structural vibration. Also, the frequency ratio is reduced with the increase of the mass ratio, while the damping rate of the liquid column increases. From the ideal liquid column parameters determined by the parametric analysis, structural response reductions of approximately 60% were achieved.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
TLCD结构减振参数研究
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.80
自引率
8.30%
发文量
37
审稿时长
>12 weeks
期刊最新文献
Reliability-based design of reinforced concrete pipes to satisfy the TEBT Innovative Approach for Enhancing GLULAM Performance with Reinforcing Steel Bars: A BESO-based Study Sequential method of topological optimization in multi-component systems Coupling Modal Analysis with the BEM for the Transient Response of Bar Structures Interacting with Three-Dimensional Soil Profiles Experimental and Numerical Study on Ballistic Impact Response of Vehicle Tires
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1