{"title":"Simultaneous Estimation and Validation of Four Antiepileptic Drugs from Bulk and Formulations Using Reverse Phase HPLC","authors":"Pooja Kole, S. Parameswaran","doi":"10.1590/s2175-97902023e20692","DOIUrl":null,"url":null,"abstract":"Epilepsy is a disorder of the central nervous system, in which the nerve cell activity in the brain is disturbed causing seizures. The objective was to develop an RP-HPLC method for consistent simultaneous quantitation of four antiepileptic drugs Levetiracetam (LVT), Lamotrigine (LTG), Phenobarbital (PBT) and Phenytoin (PTY). An isocratic method was developed on C18 column in JASCO HPLC using 5 mM potassium phosphate buffer (pH 6) and acetonitrile as the mobile phase at a flow rate of 1ml/min and detected at 230 nm using UV detector. The mean retention time for LVT, LTG, PBT and PTY were found as 2.55, 3.55, 4.65 and 5.99 minutes respectively. The method was validated as per ICH guidelines and was found to be acceptable. The %RSD value was <2.0 % thus stating the developed method was precise for the drugs in the given range. The accuracy values were within 85–115% of the recovery range. The specificity of the method was evaluated by an assay of marketed formulation, and it showed a percent content between 90–110% w/w for all the four drugs. The proposed analytical method was simple, accurate and robust and was precisely able to resolve the four major antiepileptic drugs. Hence, the current method can be applied successfully for routine examination of these drugs.","PeriodicalId":9218,"journal":{"name":"Brazilian Journal of Pharmaceutical Sciences","volume":"1 1","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2023-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Pharmaceutical Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/s2175-97902023e20692","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
Abstract
Epilepsy is a disorder of the central nervous system, in which the nerve cell activity in the brain is disturbed causing seizures. The objective was to develop an RP-HPLC method for consistent simultaneous quantitation of four antiepileptic drugs Levetiracetam (LVT), Lamotrigine (LTG), Phenobarbital (PBT) and Phenytoin (PTY). An isocratic method was developed on C18 column in JASCO HPLC using 5 mM potassium phosphate buffer (pH 6) and acetonitrile as the mobile phase at a flow rate of 1ml/min and detected at 230 nm using UV detector. The mean retention time for LVT, LTG, PBT and PTY were found as 2.55, 3.55, 4.65 and 5.99 minutes respectively. The method was validated as per ICH guidelines and was found to be acceptable. The %RSD value was <2.0 % thus stating the developed method was precise for the drugs in the given range. The accuracy values were within 85–115% of the recovery range. The specificity of the method was evaluated by an assay of marketed formulation, and it showed a percent content between 90–110% w/w for all the four drugs. The proposed analytical method was simple, accurate and robust and was precisely able to resolve the four major antiepileptic drugs. Hence, the current method can be applied successfully for routine examination of these drugs.
期刊介绍:
The Brazilian Journal of Pharmaceutical Sciences accepts for publication Original Papers applicable to the fields of Pharmaceutical Sciences; Reviews and Current Comment Articles, which are published under the Scientific Editor and Associate Editors invitation to recognized experts or when they are spontaneously submitted by the authors in the form of abstracts to have their importance evaluated. A critical view of the subject with insertions of results of previous works in the field in relation to the state of art must be included; Short Communications reporting new methods and previews of works on researches of outstanding importance in which originality justify a quick publication. A maximum of 2000 words excluding tables, figures and references is an acceptable limit. One table, one figure and ten references may be added, and Book Reviews of the latest editions of books, prepared by specialists invited by the Scientific Editor and Associate Editors. Thematic Supplements as well as those related to scientific meetings can be published under the Scientific Editor and/or Associate Editors agreement.