Inter-laboratory validation of automated SPME-GC/MS for determination of pesticides in surface and ground water samples: sensitive and green alternative to liquid–liquid extraction

IF 2 Q3 Environmental Science Water Quality Research Journal of Canada Pub Date : 2016-11-02 DOI:10.2166/WQRJC.2016.011
Ángel Rodríguez-Lafuente, Hamed Piri-Moghadam, H. Lord, Terry Obal, J. Pawliszyn
{"title":"Inter-laboratory validation of automated SPME-GC/MS for determination of pesticides in surface and ground water samples: sensitive and green alternative to liquid–liquid extraction","authors":"Ángel Rodríguez-Lafuente, Hamed Piri-Moghadam, H. Lord, Terry Obal, J. Pawliszyn","doi":"10.2166/WQRJC.2016.011","DOIUrl":null,"url":null,"abstract":"An automated solid-phase microextraction gas chromatography/mass spectometry (SPME-GC/MS) method was developed for the determination of semi-volatile pesticides from several classes with a wide range of polarities in an environmental matrix, and validated according to the rigorous standards of a large commercial laboratory reporting data requiring regulatory acceptance with the purpose of being used as a standard test protocol. The target analytes showed a detection limit of 0.05–1 μg L−1, good calibration linearity (R2 > 0.99) with a wide linear range of 0.05–20 μg L−1, and accuracy in the range of 80–110 at three levels of calibration with relative standard deviation below 7% by commercial polydimethylsiloxane/divinylbenzene (PDMS/DVB) SPME fiber. An extensive study between SPME and liquid–liquid extraction as a reference US EPA method was performed from several analytical aspects including sensitivity, accuracy, repeatability, and greenness. The SPME method was validated through split blind analyses of 16 fortified surface and ground water samples within 4 months at Maxxam Analytics, the reference laboratory, and the University of Waterloo. Both methods were shown to be very accurate, with the highest frequency of results falling in the 70–130% accuracy range. The SPME method was shown to be more sensitive than the LLE, while requiring a lower volume of sample.","PeriodicalId":54407,"journal":{"name":"Water Quality Research Journal of Canada","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2016-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2166/WQRJC.2016.011","citationCount":"25","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Quality Research Journal of Canada","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2166/WQRJC.2016.011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Environmental Science","Score":null,"Total":0}
引用次数: 25

Abstract

An automated solid-phase microextraction gas chromatography/mass spectometry (SPME-GC/MS) method was developed for the determination of semi-volatile pesticides from several classes with a wide range of polarities in an environmental matrix, and validated according to the rigorous standards of a large commercial laboratory reporting data requiring regulatory acceptance with the purpose of being used as a standard test protocol. The target analytes showed a detection limit of 0.05–1 μg L−1, good calibration linearity (R2 > 0.99) with a wide linear range of 0.05–20 μg L−1, and accuracy in the range of 80–110 at three levels of calibration with relative standard deviation below 7% by commercial polydimethylsiloxane/divinylbenzene (PDMS/DVB) SPME fiber. An extensive study between SPME and liquid–liquid extraction as a reference US EPA method was performed from several analytical aspects including sensitivity, accuracy, repeatability, and greenness. The SPME method was validated through split blind analyses of 16 fortified surface and ground water samples within 4 months at Maxxam Analytics, the reference laboratory, and the University of Waterloo. Both methods were shown to be very accurate, with the highest frequency of results falling in the 70–130% accuracy range. The SPME method was shown to be more sensitive than the LLE, while requiring a lower volume of sample.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
自动SPME-GC/MS测定地表水和地下水中农药的实验室间验证:灵敏和绿色替代液-液萃取
开发了一种自动固相微萃取气相色谱/质谱(SPME-GC/MS)方法,用于在环境基质中测定几种具有广泛极性的半挥发性农药,并根据大型商业实验室报告数据的严格标准进行验证,这些数据需要监管机构的认可,目的是作为标准测试方案使用。目标分析物的检出限为0.05 ~ 1 μ L−1,线性范围为0.05 ~ 20 μ L−1,校准线性范围为R2 > 0.99,在3级校准时精度在80 ~ 110范围内,相对标准偏差小于7%。从灵敏度、准确性、可重复性和绿色度等几个分析方面对SPME和液液萃取作为参考的US EPA方法进行了广泛的研究。在4个月内,参考实验室Maxxam Analytics和滑铁卢大学对16个强化地表水和地下水样本进行了分盲分析,验证了SPME方法的有效性。这两种方法都非常准确,结果的最高频率在70-130%的准确度范围内。结果表明,SPME法比LLE法更灵敏,同时所需的样品体积更小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
18
审稿时长
>12 weeks
期刊介绍: The Water Quality Research Journal publishes peer-reviewed, scholarly articles on the following general subject areas: Impact of current and emerging contaminants on aquatic ecosystems Aquatic ecology (ecohydrology and ecohydraulics, invasive species, biodiversity, and aquatic species at risk) Conservation and protection of aquatic environments Responsible resource development and water quality (mining, forestry, hydropower, oil and gas) Drinking water, wastewater and stormwater treatment technologies and strategies Impacts and solutions of diffuse pollution (urban and agricultural run-off) on water quality Industrial water quality Used water: Reuse and resource recovery Groundwater quality (management, remediation, fracking, legacy contaminants) Assessment of surface and subsurface water quality Regulations, economics, strategies and policies related to water quality Social science issues in relation to water quality Water quality in remote areas Water quality in cold climates The Water Quality Research Journal is a quarterly publication. It is a forum for original research dealing with the aquatic environment, and should report new and significant findings that advance the understanding of the field. Critical review articles are especially encouraged.
期刊最新文献
Carbon filtration: harnessing cotton's power to purify drinking water Development of an online analyser to meet challenging new discharge limits for mercury in flue gas desulphurisation wastewater Single-wavelength colorimetric tests for low-cost estimation of bacterial activity, chemical oxygen demand, and turbidity in domestic wastewater Evapotranspiration and crop coefficient for Typha latifolia in constructed wetlands Editorial: New Energy for Water Quality Research!
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1