An Improved Fault Detection Method for Overhead Transmission Lines Based on Differential Tunnel Magnetoresistive Sensor Array Approach

IF 2.1 Q3 COMPUTER SCIENCE, HARDWARE & ARCHITECTURE IEEE Canadian Journal of Electrical and Computer Engineering Pub Date : 2022-12-13 DOI:10.1109/ICJECE.2022.3213501
Patrick Nyaaba Ayambire;Huang Qi;Paul Oswald Kwasi Anane;Albert K. Awopone;Li Jian;Olusola Bamisile
{"title":"An Improved Fault Detection Method for Overhead Transmission Lines Based on Differential Tunnel Magnetoresistive Sensor Array Approach","authors":"Patrick Nyaaba Ayambire;Huang Qi;Paul Oswald Kwasi Anane;Albert K. Awopone;Li Jian;Olusola Bamisile","doi":"10.1109/ICJECE.2022.3213501","DOIUrl":null,"url":null,"abstract":"Overhead transmission lines play a key role in ensuring power system security and reliability in this current smart society. The overhead transmission line operates in a very complex terrain thereby making it vulnerable to various kinds of faults. Most transmission line faults lead to interruption in power supplies and therefore the need for a fast repair to restore the system to its normal state. A fast, timely, and accurate fault detection technique will ensure speedy restoration of the system thereby reducing outage time. In this article, an enhanced transmission lines’ fault detection approach is presented. This scheme deployed a highly sensitive, low cost, and energy-efficient differential sensor to detect flux density variation measured along transmission lines. The fault detection algorithm is developed for the detection of faults in transmission lines. The development is implemented on a model transmission line and tested for various fault scenarios. Scaled-up laboratory experiments were also conducted to measure magnetic flux density and fault identification to verify the validity of the proposed technique as well as estimate the amount of current produced when a fault occurred. From the simulated and measured current produced during a fault, the proposed technique yielded an estimated error of 1.38%, while the CT and a commercial current probe gave errors of 10.99% and 17.68%, respectively.","PeriodicalId":100619,"journal":{"name":"IEEE Canadian Journal of Electrical and Computer Engineering","volume":"45 4","pages":"409-417"},"PeriodicalIF":2.1000,"publicationDate":"2022-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Canadian Journal of Electrical and Computer Engineering","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/9983794/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, HARDWARE & ARCHITECTURE","Score":null,"Total":0}
引用次数: 2

Abstract

Overhead transmission lines play a key role in ensuring power system security and reliability in this current smart society. The overhead transmission line operates in a very complex terrain thereby making it vulnerable to various kinds of faults. Most transmission line faults lead to interruption in power supplies and therefore the need for a fast repair to restore the system to its normal state. A fast, timely, and accurate fault detection technique will ensure speedy restoration of the system thereby reducing outage time. In this article, an enhanced transmission lines’ fault detection approach is presented. This scheme deployed a highly sensitive, low cost, and energy-efficient differential sensor to detect flux density variation measured along transmission lines. The fault detection algorithm is developed for the detection of faults in transmission lines. The development is implemented on a model transmission line and tested for various fault scenarios. Scaled-up laboratory experiments were also conducted to measure magnetic flux density and fault identification to verify the validity of the proposed technique as well as estimate the amount of current produced when a fault occurred. From the simulated and measured current produced during a fault, the proposed technique yielded an estimated error of 1.38%, while the CT and a commercial current probe gave errors of 10.99% and 17.68%, respectively.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种改进的基于差分隧道磁阻传感器阵列法的架空输电线路故障检测方法
在当前的智能社会中,架空输电线路在确保电力系统安全和可靠性方面发挥着关键作用。架空输电线路在非常复杂的地形中运行,因此容易受到各种故障的影响。大多数输电线路故障会导致电源中断,因此需要快速修复以将系统恢复到正常状态。快速、及时、准确的故障检测技术将确保系统的快速恢复,从而减少停机时间。本文提出了一种增强型输电线路故障检测方法。该方案部署了一种高灵敏度、低成本、高能效的差分传感器来检测沿传输线测量的通量密度变化。故障检测算法是为检测输电线路中的故障而开发的。该开发在输电线路模型上实施,并针对各种故障场景进行了测试。还进行了扩大规模的实验室实验来测量磁通密度和故障识别,以验证所提出的技术的有效性,并估计故障发生时产生的电流量。根据故障期间产生的模拟和测量电流,所提出的技术产生了1.38%的估计误差,而CT和商用电流探针分别产生了10.99%和17.68%的误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.70
自引率
0.00%
发文量
0
期刊最新文献
Table of Contents Front Cover IEEE Canadian Journal of Electrical and Computer Engineering Green Electricity Share Enhancement Through Rooftop Solar PV System on Institutional Sheds Enhanced Validation of Intelligent Control Algorithms in AC Microgrids
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1