{"title":"Overestimation of Mean Heart Rate by the Arithmetic Average of Beat-By-Beat Sampled Heart Rate Values","authors":"H. Stauss, K. Rarick","doi":"10.2174/1876526201104010033","DOIUrl":null,"url":null,"abstract":"The arithmetic average of beat-by-beat sampled heart rate (HR) values overestimates true HR defined as number of heart beats per time unit. The aims of this study were to (1) estimate the magnitude of overestimation; (2) illustrate the significance of this issue using data from patients with congestive heart failure (CHF) and control subjects; and (3) outline approaches to correctly calculate mean HR. Linear regression analysis of computer-generated time series, representing beat-by-beat HR values in humans, rats, and mice, revealed that the difference between the arithmetic average of beat-by-beat sampled HR values and the true mean HR (error e) can be approximated by the variance (σ 2 ) divided by the arithmetic average (µ) of the beat-by-beat HR values (e = σ 2 /µ). True mean HR was higher in patients with CHF (92.9±4.3 bpm) than in control subjects (82.6±2.1 bpm, P=0.045). However, if mean HR was calculated as arithmetic average of the beat-by-beat HR values the difference in mean HR was no longer significant (93.4±4.4 bpm in CHF vs. 83.8±2.1 bpm in controls, P=0.059). In conclusion, the arithmetic average of beat-by-beat sampled HR values overestimates true HR by approximately the ratio of σ 2 to µ of the beat-by-beat HR values. Thus, the error (e) is largest in subjects with high HR variability and low average HR and may affect interpretation of mean HR values in studies investigating populations of subjects with differing HR variability, such as CHF patients vs. healthy subject or old vs. young subjects.","PeriodicalId":38918,"journal":{"name":"Open Hypertension Journal","volume":"4 1","pages":"33-36"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Hypertension Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1876526201104010033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

The arithmetic average of beat-by-beat sampled heart rate (HR) values overestimates true HR defined as number of heart beats per time unit. The aims of this study were to (1) estimate the magnitude of overestimation; (2) illustrate the significance of this issue using data from patients with congestive heart failure (CHF) and control subjects; and (3) outline approaches to correctly calculate mean HR. Linear regression analysis of computer-generated time series, representing beat-by-beat HR values in humans, rats, and mice, revealed that the difference between the arithmetic average of beat-by-beat sampled HR values and the true mean HR (error e) can be approximated by the variance (σ 2 ) divided by the arithmetic average (µ) of the beat-by-beat HR values (e = σ 2 /µ). True mean HR was higher in patients with CHF (92.9±4.3 bpm) than in control subjects (82.6±2.1 bpm, P=0.045). However, if mean HR was calculated as arithmetic average of the beat-by-beat HR values the difference in mean HR was no longer significant (93.4±4.4 bpm in CHF vs. 83.8±2.1 bpm in controls, P=0.059). In conclusion, the arithmetic average of beat-by-beat sampled HR values overestimates true HR by approximately the ratio of σ 2 to µ of the beat-by-beat HR values. Thus, the error (e) is largest in subjects with high HR variability and low average HR and may affect interpretation of mean HR values in studies investigating populations of subjects with differing HR variability, such as CHF patients vs. healthy subject or old vs. young subjects.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用逐拍采样心率值的算术平均值高估平均心率
按次心跳采样心率(HR)值的算术平均值高估了定义为每单位时间内心跳次数的真实HR。本研究的目的是:(1)估计高估的程度;(2)利用充血性心力衰竭(CHF)患者和对照组的数据说明这一问题的重要性;(3)概述了正确计算平均人力资源的方法。对计算机生成的人类、大鼠和小鼠的心跳率时间序列进行线性回归分析,发现心跳率采样值的算术平均值与真实平均心率(误差e)的差值可以近似为方差(σ 2)除以心跳率的算术平均值(e = σ 2 /µ)。CHF患者的真实平均心率(92.9±4.3 bpm)高于对照组(82.6±2.1 bpm, P=0.045)。然而,如果将平均HR计算为逐搏心率值的算术平均值,则平均HR的差异不再显著(CHF组93.4±4.4 bpm vs对照组83.8±2.1 bpm, P=0.059)。综上所述,逐拍采样HR值的算术平均值高估了真实HR值,其近似于逐拍HR值的σ 2与µ之比。因此,误差(e)在人力资源高变异性和平均人力资源低的受试者中最大,并可能影响在调查具有不同人力资源变异性的受试者群体(如心力衰竭患者与健康受试者或老年人与年轻人受试者)的研究中对平均人力资源值的解释。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Open Hypertension Journal
Open Hypertension Journal Medicine-Cardiology and Cardiovascular Medicine
自引率
0.00%
发文量
0
期刊最新文献
Implementation of a Resistant Hypertension Control Program in a Low-income Primary Care Setting in a High-Income Country: Lessons Learned and Global Applicability Troponin and B-type Natriuretic Peptides Biomarkers in the Management of Hypertension Hypertension in end-stage kidney disease Confirming a Diagnosis of "Hypertension" Sodium-glucose Co-transporter 2 Inhibitors and Blood Pressure Reduction among Patients with Diabetes, Cardiovascular Disease, Chronic Kidney Disease
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1