{"title":"Current Sharing Temperature of the ITER-TF Insert","authors":"Y. Nunoya, M. Sugimoto, T. Isono, K. Hamada, K. Matsui, K. Okuno","doi":"10.2221/JCSJ.37.523","DOIUrl":null,"url":null,"abstract":"The Central Solenoid (CS) model coil program was established in 1992 as one of projects in the Engineering Design Activities (EDA) of the International Thermonuclear Experimental Reacter (ITER). Current sharing temperature (Tcs) measurement of an ITER toroidal field insert (TF insert) was performed. The coil is a Nb3Sn superconducting coil, and was installed inside of the ITER CS model coil as a backup field coil. The relation between the voltage of an individual strand composed of the TF insert conductor and the measured voltage using the taps on the jacket were investigated, and evaluation method for Tcs measurement was established. The obtained results show that there was a discrepancy between the expected value from the strand data and the measured value, which is lower by about 1.2K. Some discrepancy was observed just after cooling down the insert before energizing.","PeriodicalId":93144,"journal":{"name":"Teion kogaku = Cryogenic engineering : [official journal of the Cryogenic Association of Japan]","volume":"37 1","pages":"523-530"},"PeriodicalIF":0.0000,"publicationDate":"2002-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Teion kogaku = Cryogenic engineering : [official journal of the Cryogenic Association of Japan]","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2221/JCSJ.37.523","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The Central Solenoid (CS) model coil program was established in 1992 as one of projects in the Engineering Design Activities (EDA) of the International Thermonuclear Experimental Reacter (ITER). Current sharing temperature (Tcs) measurement of an ITER toroidal field insert (TF insert) was performed. The coil is a Nb3Sn superconducting coil, and was installed inside of the ITER CS model coil as a backup field coil. The relation between the voltage of an individual strand composed of the TF insert conductor and the measured voltage using the taps on the jacket were investigated, and evaluation method for Tcs measurement was established. The obtained results show that there was a discrepancy between the expected value from the strand data and the measured value, which is lower by about 1.2K. Some discrepancy was observed just after cooling down the insert before energizing.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ITER-TF插片的电流共享温度
中央螺线管(CS)模型线圈项目成立于1992年,是国际热核实验反应堆(ITER)工程设计活动(EDA)项目之一。对ITER环形场插片(TF插片)进行了电流共享温度(Tcs)测量。该线圈为Nb3Sn超导线圈,安装在ITER CS模型线圈内部作为备用场线圈。研究了由TF插入导体组成的单链电压与夹套上抽头测量电压的关系,建立了Tcs测量的评价方法。得到的结果表明,从链数据中得到的期望值与实测值之间存在较大的差异,差了1.2K左右。在通电前对插入件进行冷却后,观察到一些差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
特集「最先端分野で活躍する超伝導エレクトロニクス技術」に寄せて Superconducting Sensing Technology Corporation (SUSTEC) Development of Superconductors for Fusion Reactors in the Superconducting Magnet System Laboratory, National Institute for Fusion Science Precision Measurement Techniques of Thermophysical Properties 特集「低温域における精密計測技術」に寄せて
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1