The use of contrast enhancement in the diagnosis of simple and complex cysts kidneys

Yaroslav A. Soloviev, L. Mitina, B. Alekseev, S. Stepanov, A. Kalpinskiy, O. V. Dimitrov, E. A. Nazoikin
{"title":"The use of contrast enhancement in the diagnosis of simple and complex cysts kidneys","authors":"Yaroslav A. Soloviev, L. Mitina, B. Alekseev, S. Stepanov, A. Kalpinskiy, O. V. Dimitrov, E. A. Nazoikin","doi":"10.24931/2413-9432-2020-9-1-27-33","DOIUrl":null,"url":null,"abstract":"In developed countries, the main methods of research and dynamic monitoring of cystic kidney formations are CT and MRI, but their use is impossible in patients with severe concomitant diseases, as well as in the presence of metal structures, pacemakers, etc. Additionally, taking into account the high dose of radiation exposure when using CT obtained by the patient during dynamic observation, the development of alternative methods is relevant. These include, but not limited to, ultrasound using contrast enhancement, which can be used as an alternative or additional method in primary diagnosis or in the dynamic observation of cystic kidney formations. In the article, the authors provide their own experience with the use of an ultrasound contrast medium for the diagnosis and dynamic observation of complex kidney cysts, as well as the introduction of ultrasound observation using a contrast medium to classify patients according to Bosniak M.A.The study included the results of the use of contrast enhanced ultrasound (CEUS) in 28 patients with various cystic formations of the kidneys. The patients were previously divided into two groups: the first consisted of 13 patients with simple cysts, the second – 15 with suspected complex cysts. As a result of the study, the patients were distributed as follows: 15 patients were classified as Bosniak type I, 7 patients – as type II, 3 - type III, 3 - type IV. The studied CEUS method is simple and effective. The specificity of the method was 78.57%, the accuracy of the method was 85.71%, the predictive value of the positive result was 81.25%, and the predictive value of the negative result was 91.66%. CEUS helps to quickly and accurately conduct differential diagnosis between a simple cyst and a complex one, as well as classify cysts according to M.A. Bosniak.","PeriodicalId":37713,"journal":{"name":"Biomedical Photonics","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Photonics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24931/2413-9432-2020-9-1-27-33","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

Abstract

In developed countries, the main methods of research and dynamic monitoring of cystic kidney formations are CT and MRI, but their use is impossible in patients with severe concomitant diseases, as well as in the presence of metal structures, pacemakers, etc. Additionally, taking into account the high dose of radiation exposure when using CT obtained by the patient during dynamic observation, the development of alternative methods is relevant. These include, but not limited to, ultrasound using contrast enhancement, which can be used as an alternative or additional method in primary diagnosis or in the dynamic observation of cystic kidney formations. In the article, the authors provide their own experience with the use of an ultrasound contrast medium for the diagnosis and dynamic observation of complex kidney cysts, as well as the introduction of ultrasound observation using a contrast medium to classify patients according to Bosniak M.A.The study included the results of the use of contrast enhanced ultrasound (CEUS) in 28 patients with various cystic formations of the kidneys. The patients were previously divided into two groups: the first consisted of 13 patients with simple cysts, the second – 15 with suspected complex cysts. As a result of the study, the patients were distributed as follows: 15 patients were classified as Bosniak type I, 7 patients – as type II, 3 - type III, 3 - type IV. The studied CEUS method is simple and effective. The specificity of the method was 78.57%, the accuracy of the method was 85.71%, the predictive value of the positive result was 81.25%, and the predictive value of the negative result was 91.66%. CEUS helps to quickly and accurately conduct differential diagnosis between a simple cyst and a complex one, as well as classify cysts according to M.A. Bosniak.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
对比增强在单纯性和复合性肾囊肿诊断中的应用
在发达国家,研究和动态监测囊肾形成的主要方法是CT和MRI,但在伴有严重并发症的患者中,以及存在金属结构、起搏器等情况下,不可能使用这些方法。此外,考虑到患者在动态观察期间使用CT时获得的高剂量辐射暴露,开发替代方法是相关的。这些包括但不限于使用对比增强的超声,它可以用作初步诊断或囊肾形成动态观察的替代或附加方法。在文章中,作者提供了自己使用超声造影剂对复杂肾囊肿的诊断和动态观察的经验,并介绍了使用造影剂对患者进行分类的超声观察,根据Bosniak m.a。该研究包括28例不同肾脏囊性形成的患者使用超声造影(CEUS)的结果。患者先前分为两组:第一组有13例单纯性囊肿,第二组有15例疑似复杂囊肿。根据研究结果,患者分布如下:15例为Bosniak I型,7例为II型,3例为III型,3例为IV型。所研究的超声造影方法简单有效。该方法特异性为78.57%,准确度为85.71%,阳性结果预测值为81.25%,阴性结果预测值为91.66%。超声造影有助于快速准确地对单纯性囊肿和复杂性囊肿进行鉴别诊断,并根据M.A. Bosniak对囊肿进行分类。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biomedical Photonics
Biomedical Photonics Medicine-Surgery
CiteScore
1.80
自引率
0.00%
发文量
19
审稿时长
8 weeks
期刊介绍: The main goal of the journal – to promote the development of Russian biomedical photonics and implementation of its advances into medical practice. The primary objectives: - Presentation of up-to-date results of scientific and in research and scientific and practical (clinical and experimental) activity in the field of biomedical photonics. - Development of united Russian media for integration of knowledge and experience of scientists and practitioners in this field. - Distribution of best practices in laser medicine to regions. - Keeping the clinicians informed about new methods and devices for laser medicine - Approval of investigations of Ph.D candidates and applicants.
期刊最新文献
Photodynamic therapy in the treatment of HPV-associated cervical cancer: mechanisms, challenges and future prospects Photodynamic therapy of leukoplakia of the oral mucosa: experience of using method in 223 patients Photodynamic therapy in treatment of squamous cell carcinoma of oral cavity with chlorine e6 photosensitizer with long-term follow up Effects of silver nanoparticle and low-level laser on the immune response and healing of albino mice skin wounds Effectiveness of 650 nm red laser photobiomodulation therapy to accelerate wound healing post tooth extraction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1