{"title":"Rotating brush for fast removal of corneal epithelium.","authors":"I. Pallikaris, A. Karoutis, S. Lydataki, D. Siganos","doi":"10.3928/1081-597X-19940701-11","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nA simple new device is proposed for safe and very fast epithelial removal of the cornea. This is a rotating plastic brush that removes the corneal epithelium within a few seconds under irrigation, without causing any mechanical damage to the stromal surface.\n\n\nMETHODS\nComparative SEM and TEM studies on rabbit corneas were carried out following epithelial removal by rotating brush and by a Beaver knife blade. Epithelial removal time and reepithelialization time after photorefractive keratectomy were evaluated in a series of 40 human sighted eyes treated with the brush.\n\n\nRESULTS\nThe rotating brush-abraded surface was smoother compared to the blade-abraded one. Additionally, the brush provoked no damage to the basal lamina of the rabbit corneal epithelium. In human photorefractive keratectomy, the mean time needed for removal of the corneal epithelium by the rotating brush was only 3 sec (range, 2-5 sec). Reepithelialization time following photorefractive keratectomy did not exceed 3 days.\n\n\nCONCLUSION\nExperimental and preliminary clinical studies suggest that the new rotating plastic brush is a safe and fast method for removing the corneal epithelium.","PeriodicalId":79348,"journal":{"name":"Journal of refractive and corneal surgery","volume":"10 4 1","pages":"439-42"},"PeriodicalIF":0.0000,"publicationDate":"1994-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"39","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive and corneal surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3928/1081-597X-19940701-11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 39

Abstract

BACKGROUND A simple new device is proposed for safe and very fast epithelial removal of the cornea. This is a rotating plastic brush that removes the corneal epithelium within a few seconds under irrigation, without causing any mechanical damage to the stromal surface. METHODS Comparative SEM and TEM studies on rabbit corneas were carried out following epithelial removal by rotating brush and by a Beaver knife blade. Epithelial removal time and reepithelialization time after photorefractive keratectomy were evaluated in a series of 40 human sighted eyes treated with the brush. RESULTS The rotating brush-abraded surface was smoother compared to the blade-abraded one. Additionally, the brush provoked no damage to the basal lamina of the rabbit corneal epithelium. In human photorefractive keratectomy, the mean time needed for removal of the corneal epithelium by the rotating brush was only 3 sec (range, 2-5 sec). Reepithelialization time following photorefractive keratectomy did not exceed 3 days. CONCLUSION Experimental and preliminary clinical studies suggest that the new rotating plastic brush is a safe and fast method for removing the corneal epithelium.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
旋转刷用于快速去除角膜上皮。
背景:提出一种简单、安全、快速的角膜上皮切除新装置。这是一种旋转的塑料刷,可以在冲洗下几秒钟内清除角膜上皮,而不会对基质表面造成任何机械损伤。方法采用旋转毛刷法和海狸刀对兔角膜上皮进行去除后的扫描电镜和透射电镜对比研究。对40只视力正常的人眼进行光屈光性角膜切除术后上皮细胞去除时间和再上皮化时间的评估。结果旋转刷磨表面比刀片磨表面光滑。此外,刷对兔角膜上皮基底层无损伤。在人类光屈光性角膜切除术中,旋转刷去除角膜上皮的平均时间仅为3秒(范围2-5秒)。光屈光性角膜切除术后再上皮化时间不超过3天。结论实验和初步临床研究表明,新型旋转塑料刷是一种安全、快速的角膜上皮清除方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effects of laser photocoagulation on corneal neovascularization in rabbits. Treatment of corneal abrasions with soft contact lenses and topical diclofenac. Presumed epithelial cyst in the anterior chamber following refractive keratotomy. Mastel Byron Radial Keratotomy Guide. Simple method of transscleral fixation of a posterior chamber intraocular lens in the absence of the lens capsule.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1