Real-Time Highly Sensitive Measurement of Myocardial Infarction Biomarkers Using Silicon-Based Ellipsometric Biosensors

Y. G. Min, H. Cho, Jo Jae Heung
{"title":"Real-Time Highly Sensitive Measurement of Myocardial Infarction Biomarkers Using Silicon-Based Ellipsometric Biosensors","authors":"Y. G. Min, H. Cho, Jo Jae Heung","doi":"10.3807/KJOP.2019.30.2.059","DOIUrl":null,"url":null,"abstract":"$2^{\\circ}$ 기울어진 산화막 코팅 실리콘 기판의 바이오칩과 프리즘으로 제작한 바이오센서와 검광자 회전 타원편광계를 이용하여 심근경색 생체표지자인 미오글로빈과 cTnI의 진단 농도를 수백 초 내에 실시간 초고감도로 측정하는데 성공하였다. 러닝 버퍼로는 순수한 phosphate buffered saline (PBS) 또는 PBS에 10% ...","PeriodicalId":42467,"journal":{"name":"Korean Journal of Optics and Photonics","volume":"30 1","pages":"59-66"},"PeriodicalIF":0.1000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Optics and Photonics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3807/KJOP.2019.30.2.059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0

Abstract

$2^{\circ}$ 기울어진 산화막 코팅 실리콘 기판의 바이오칩과 프리즘으로 제작한 바이오센서와 검광자 회전 타원편광계를 이용하여 심근경색 생체표지자인 미오글로빈과 cTnI의 진단 농도를 수백 초 내에 실시간 초고감도로 측정하는데 성공하였다. 러닝 버퍼로는 순수한 phosphate buffered saline (PBS) 또는 PBS에 10% ...
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用硅基椭偏生物传感器实时高灵敏度测量心肌梗死生物标志物
$2^{\circ}利用倾斜的氧化膜涂层硅基板的生物芯片和用棱镜制作的生物传感器和检光子旋转椭圆偏光计,成功在数百秒内实时以超高灵敏度测定心肌梗塞生物标志——肌红蛋白和cTnI的诊断浓度。跑步缓冲10%用于纯粹的phosphate buffered saline或PBS…
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The gap between perceived mental health needs and actual service utilization in Australian adolescents. A Study of the Design of Automotive Communication Lamps Using Microlens Arrays Linearly Polarized 1-kW 20/400-㎛ Yb-doped Fiber Laser with 10-GHz Linewidth 3-channel Tiled-aperture Coherent-beam-combining System Based on Target-in-the-loop Monitoring and SPGD Algorithm A Study on Performance and Sensitivity Improvement of an Off-axis TMA Telescope Optical System by Changing the Aperture-stop Position
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1