Tunica vaginalis flap cover in hypospadias cripples: Our experience in a tertiary care center in India

N. Sharma, M. Bajpai, S. Panda, A. Verma, Mini Sharma
{"title":"Tunica vaginalis flap cover in hypospadias cripples: Our experience in a tertiary care center in India","authors":"N. Sharma, M. Bajpai, S. Panda, A. Verma, Mini Sharma","doi":"10.4103/1116-5898.134533","DOIUrl":null,"url":null,"abstract":"Objective: The objective of the following study is to assess the outcome of treatment with tunica vaginalis flap cover in cases of proximal penile hypospadias cripples. Materials and Methods: This retrospective study included cases of proximal penile hypospadias cripples managed by thiersch-duplay urethroplasty. Cases were divided into three groups. Group I included cases with tunica vaginalis flap, group II with dartos flap and group III included staged hypospadias repair on Bracka′s principle. All cases were managed by a uniform protocol. Outcome was assessed at day 10 after stent removal and at first follow-up. Urethroplasty was considered successful in case with no leak. P value was considered to be significant if less than 0.05. Results: Out of 67 cases, 18 cases were in group I, 24 cases were in group II and 24 were in group III. They formed the study group. Leak at the time of stent removal was present in 1/18 (5.57%), 4/24 (16.67%), 2/24 (8.33%) cases in group 1, II and III respectively (P = 0.04 and 0.4). Leak at the time of first follow-up was present in 1/18 (5.55%), 5/24 (20.83%) and 3/24 (25%) cases in group I, II and III respectively (P = 0.03 and 0.3). Complete disruption of urethroplasty was present in 1/18 (5.57%), 2/24 (8.83%) and 1/24 (4.16%) cases in group I, II and III respectively (P = 0.1). The overall success rate in group I, II and III were 15/18 (83.83%), 13/24 (54.16%) and 18/24 (75%) respectively (P = 0.01 and 0.1). Conclusions: Tunica vaginalis flap reinforcement in cases of hypospadias cripples is a viable and reliable option. This should be favored over dartos flap.","PeriodicalId":90935,"journal":{"name":"Nigerian journal of surgical sciences : official journal of the Nigerian Section of International College of Surgeons","volume":"24 1","pages":"7 - 11"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nigerian journal of surgical sciences : official journal of the Nigerian Section of International College of Surgeons","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/1116-5898.134533","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Objective: The objective of the following study is to assess the outcome of treatment with tunica vaginalis flap cover in cases of proximal penile hypospadias cripples. Materials and Methods: This retrospective study included cases of proximal penile hypospadias cripples managed by thiersch-duplay urethroplasty. Cases were divided into three groups. Group I included cases with tunica vaginalis flap, group II with dartos flap and group III included staged hypospadias repair on Bracka′s principle. All cases were managed by a uniform protocol. Outcome was assessed at day 10 after stent removal and at first follow-up. Urethroplasty was considered successful in case with no leak. P value was considered to be significant if less than 0.05. Results: Out of 67 cases, 18 cases were in group I, 24 cases were in group II and 24 were in group III. They formed the study group. Leak at the time of stent removal was present in 1/18 (5.57%), 4/24 (16.67%), 2/24 (8.33%) cases in group 1, II and III respectively (P = 0.04 and 0.4). Leak at the time of first follow-up was present in 1/18 (5.55%), 5/24 (20.83%) and 3/24 (25%) cases in group I, II and III respectively (P = 0.03 and 0.3). Complete disruption of urethroplasty was present in 1/18 (5.57%), 2/24 (8.83%) and 1/24 (4.16%) cases in group I, II and III respectively (P = 0.1). The overall success rate in group I, II and III were 15/18 (83.83%), 13/24 (54.16%) and 18/24 (75%) respectively (P = 0.01 and 0.1). Conclusions: Tunica vaginalis flap reinforcement in cases of hypospadias cripples is a viable and reliable option. This should be favored over dartos flap.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
阴道膜瓣覆盖在尿道下裂残障:我们在印度三级保健中心的经验
目的:探讨阴道膜瓣覆盖治疗阴茎近端尿道下裂的效果。材料和方法:本回顾性研究包括采用thiersch-duplay尿道成形术治疗阴茎近端尿道下裂的病例。病例分为三组。第一组采用阴道膜瓣,第二组采用肛门瓣,第三组采用Bracka原则分阶段修复尿道下裂。所有病例均按统一方案处理。在支架移除后第10天和第一次随访时评估结果。尿道成形术成功的情况下,没有泄漏。若P值小于0.05,则认为P值显著。结果:67例患者中,ⅰ组18例,ⅱ组24例,ⅲ组24例。他们组成了学习小组。1、II、III组分别有1/18(5.57%)、4/24(16.67%)、2/24(8.33%)例出现支架取出时渗漏(P = 0.04、0.4)。ⅰ组、ⅱ组和ⅲ组首次随访时出现渗漏的分别为1/18(5.55%)、5/24(20.83%)和3/24 (25%)(P = 0.03和0.3)。I组、II组和III组完全尿道成形术破裂的发生率分别为1/18(5.57%)、2/24(8.83%)和1/24 (4.16%)(P = 0.1)。I、II、III组总成功率分别为15/18(83.83%)、13/24(54.16%)、18/24 (75%)(P = 0.01、0.1)。结论:阴道膜瓣加固治疗尿道下裂是一种可行、可靠的方法。这应该比飞镖瓣更受欢迎。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Catheter associated urinary tract infection offending pathogens, antimicrobial sensitivity, and complications Early postoperative wound infections in hemiarthroplasties in South-South, Nigeria: A multicenter-based study Unoperated tetralogy of fallot: A natural survivor who refused for surgery at the age of 42 years – Was it ever too late to operate? Long loop vas – A rare entity: Case report and review of literature Parosteal osteosarcoma of the maxilla: A case report and review of the literature
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1