Simple Quantitation of Flucytosine in Low Volume Serum Samples and Evaluation of Common Endogenous Interferences by HPLC-UV

Abdul Rafiq Khan, A. Alothaim, W. Tamimi, Majid Alshaibani, Souad Marwan Al Enazi, S. Saad, K. M. Khan
{"title":"Simple Quantitation of Flucytosine in Low Volume Serum Samples and Evaluation of Common Endogenous Interferences by HPLC-UV","authors":"Abdul Rafiq Khan, A. Alothaim, W. Tamimi, Majid Alshaibani, Souad Marwan Al Enazi, S. Saad, K. M. Khan","doi":"10.4236/ajac.2022.139020","DOIUrl":null,"url":null,"abstract":"5-Fluorocytosine (5-FC) is used for the treatment of several infections. It is extremely important to monitor blood level concentration for maximum ac-tivity to avoid its side effects. A simple, faster, and more accurate analytical method is developed and validated using high-performance liquid chromatography with UV detection in a very low-volume serum sample. Exactly 50 µL of serum was precipitated with 5% trichloroacetic acid. After mixing and centrifugation, 20 µL of supernatant was injected into the HPLC column. Detection was performed at 280 nm. The method is very specific and free from interfering substances due to different drugs and their different circulating metabolites. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.50 μg/L and 1.0 μg/L, respectively. The method was linear in the range of 5 - 150 μg/L in the serum sample. In method comparison, the correlation coefficient r 2 was 0.999 and the percentage recovery was 90% - 105% on four levels of the quality control samples. Within run and between run precision was found to be less than 2.2% at four different concentrations (5, 25, 50, and 100 μg/L). A simple, faster, and more accurate HPLC-UV method is developed which is very useful for monitoring 5-FC concentration in low volume serum samples without evaporation step and ion exchange chromatography within minutes.","PeriodicalId":63216,"journal":{"name":"美国分析化学(英文)","volume":"144 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"美国分析化学(英文)","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.4236/ajac.2022.139020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

5-Fluorocytosine (5-FC) is used for the treatment of several infections. It is extremely important to monitor blood level concentration for maximum ac-tivity to avoid its side effects. A simple, faster, and more accurate analytical method is developed and validated using high-performance liquid chromatography with UV detection in a very low-volume serum sample. Exactly 50 µL of serum was precipitated with 5% trichloroacetic acid. After mixing and centrifugation, 20 µL of supernatant was injected into the HPLC column. Detection was performed at 280 nm. The method is very specific and free from interfering substances due to different drugs and their different circulating metabolites. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.50 μg/L and 1.0 μg/L, respectively. The method was linear in the range of 5 - 150 μg/L in the serum sample. In method comparison, the correlation coefficient r 2 was 0.999 and the percentage recovery was 90% - 105% on four levels of the quality control samples. Within run and between run precision was found to be less than 2.2% at four different concentrations (5, 25, 50, and 100 μg/L). A simple, faster, and more accurate HPLC-UV method is developed which is very useful for monitoring 5-FC concentration in low volume serum samples without evaporation step and ion exchange chromatography within minutes.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
低容量血清中氟胞嘧啶的简单定量及常见内源干扰的HPLC-UV评价
5-氟胞嘧啶(5-FC)用于治疗几种感染。监测血药浓度以获得最大活性以避免其副作用是非常重要的。开发了一种简单、快速、更准确的分析方法,并在非常小体积的血清样品中使用高效液相色谱和紫外检测进行了验证。用5%三氯乙酸沉淀50µL血清。混合离心后,将上清液20µL注入高效液相色谱柱。在280 nm处检测。该方法特异性强,不受不同药物及其循环代谢产物的干扰。检测限和定量限分别为0.50 μg/L和1.0 μg/L。该方法在血清样品中5 ~ 150 μg/L范围内呈线性。方法比较中,4个质量控制样品的相关系数r2为0.999,回收率为90% ~ 105%。在4种不同浓度(5、25、50、100 μg/L)下,组内和组间精密度均小于2.2%。建立了一种简单、快速、准确的HPLC-UV方法,可在几分钟内监测低体积血清样品中的5-FC浓度,无需蒸发步骤和离子交换色谱。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
826
期刊最新文献
Empirical Investigation of Treatment of Sour Gas by Novel Technology: Energy Optimization Modeling of Fixed Bed Adsorption Column Parameters of Iron(II) Removal Using Ferrihydrite Coated Brick A Comparative Study of Transesterification of Hydnocapus weightiana Seed Oil Using Calcined and Acid Activated Natural Heterogeneous Catalyst and Its Kinetic Study Determination of Atomic Fractions of Isotopes Carbon-13 and Nitrogen-15 Directly in Glicine, L-Leucine, Isoleucine and Alanine Application and Development Trends of Spectral Analysis in Draft of Non-Ferrous Metal Standards in China
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1