{"title":"Particulate Matter in the Korea Train eXpress (KTX) Cabin and its Exposure","authors":"Chang-Jin Ma,&nbsp;Gong-Unn Kang","doi":"10.5572/ajae.2022.041","DOIUrl":null,"url":null,"abstract":"<div><p>This study aims to assess the particulate matter (PM<sub>1</sub>, PM<sub>2.5</sub>, PM<sub>10</sub>) and black carbon (BC) in the Korea Train eXpress (KTX) cabin during train running, and the personal exposure of PM<sub>2.5</sub> for the female/male passengers who use the KTX 20 days a month to commute. Intensive measurements were made on the day when the outside ambient PM concentration was much higher than usual. To compare with the PM concentration in the subway cabin, a measurement was also performed in some sections of the Seoul Metro subway (from Namyoung Station (hereafter referred to as the “Sta.”) to Jonggak Sta.). The amount of PM<sub>2.5</sub> exposure </p><div><figure><div><div><picture><source><img></source></picture></div></div></figure></div><p> was calculated for the male/female passengers who regularly board the KTX. The </p><div><figure><div><div><picture><source><img></source></picture></div></div></figure></div><p>, which is the amount of PM<sub>2.5</sub> exposure when moving by car in the same section, was also calculated. The PM concentration in the KTX cabin elevated and fallen off at train staying and train running, respectively. The PM<sub>2.5</sub> concentrations inside KTX cabin at the stop station exhibited a remarkable positive correlation with those of outdoor. Compared to the PM concentration measured in the cabin of Seoul Metro subway, PM<sub>1</sub>, PM<sub>2.5</sub>, and PM<sub>10</sub> in the KTX passenger cabin were 74.9%, 73.3%, and 62.7% of those in the cabin of Seoul Metro subway, respectively. The PM<sub>2.5</sub> exposure amount (exposure PM<sub>2.5</sub> (μg)) when moving the same section using the KTX and passenger cars was calculated, and as a result, the exposure PM<sub>2.5</sub> (μg) for both male and female were 5.7 times lower in the KTX than that in car. The mapping result of BC concentration drawn on the KTX line from Iksan Sta. to Gwang-myeong Sta. shows that it fluctuated greatly for each service section or stop station.</p></div>","PeriodicalId":45358,"journal":{"name":"Asian Journal of Atmospheric Environment","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2022-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.5572/ajae.2022.041.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Atmospheric Environment","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.5572/ajae.2022.041","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"METEOROLOGY & ATMOSPHERIC SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

This study aims to assess the particulate matter (PM1, PM2.5, PM10) and black carbon (BC) in the Korea Train eXpress (KTX) cabin during train running, and the personal exposure of PM2.5 for the female/male passengers who use the KTX 20 days a month to commute. Intensive measurements were made on the day when the outside ambient PM concentration was much higher than usual. To compare with the PM concentration in the subway cabin, a measurement was also performed in some sections of the Seoul Metro subway (from Namyoung Station (hereafter referred to as the “Sta.”) to Jonggak Sta.). The amount of PM2.5 exposure

was calculated for the male/female passengers who regularly board the KTX. The

, which is the amount of PM2.5 exposure when moving by car in the same section, was also calculated. The PM concentration in the KTX cabin elevated and fallen off at train staying and train running, respectively. The PM2.5 concentrations inside KTX cabin at the stop station exhibited a remarkable positive correlation with those of outdoor. Compared to the PM concentration measured in the cabin of Seoul Metro subway, PM1, PM2.5, and PM10 in the KTX passenger cabin were 74.9%, 73.3%, and 62.7% of those in the cabin of Seoul Metro subway, respectively. The PM2.5 exposure amount (exposure PM2.5 (μg)) when moving the same section using the KTX and passenger cars was calculated, and as a result, the exposure PM2.5 (μg) for both male and female were 5.7 times lower in the KTX than that in car. The mapping result of BC concentration drawn on the KTX line from Iksan Sta. to Gwang-myeong Sta. shows that it fluctuated greatly for each service section or stop station.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
韩国高速列车(KTX)车厢内的微粒物质及其暴露情况
本研究旨在评估韩国高速列车(KTX)列车运行过程中车厢内的颗粒物(PM1、PM2.5、PM10)和黑碳(BC),以及每月 20 天乘坐韩国高速列车上下班的女性/男性乘客个人接触 PM2.5 的情况。在室外环境可吸入颗粒物浓度比平时高得多的当天进行了密集测量。为了与地铁车厢内的 PM 浓度进行比较,还在首尔地铁的部分路段(从 Namyoung 站(以下简称 "车站")到 Jonggak 站)进行了测量。对经常乘坐 KTX 的男性/女性乘客的 PM2.5 暴露量进行了计算。此外,还计算了在同一路段乘车时的 PM2.5 暴露量。KTX车厢内的PM浓度分别在列车停留和列车运行时升高和降低。停靠站 KTX 车厢内的 PM2.5 浓度与室外的 PM2.5 浓度呈显著正相关。与首尔地铁车厢内测得的 PM 浓度相比,KTX 乘客车厢内的 PM1、PM2.5 和 PM10 分别是首尔地铁车厢内的 74.9%、73.3% 和 62.7%。计算了使用 KTX 和客车行驶同一路段时的 PM2.5 暴露量(暴露 PM2.5(μg)),结果显示,男性和女性的 PM2.5 暴露量(μg)在 KTX 中比在汽车中低 5.7 倍。从益山站到光明站的 KTX 线路上绘制的 BC 浓度图结果显示,各服务区或停靠站的 BC 浓度波动很大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Asian Journal of Atmospheric Environment
Asian Journal of Atmospheric Environment METEOROLOGY & ATMOSPHERIC SCIENCES-
CiteScore
2.80
自引率
6.70%
发文量
22
审稿时长
21 weeks
期刊最新文献
Characteristic of PM2.5 concentration and source apportionment during winter in Seosan, Korea A case study on the effect of contaminated inlet tubes on the accuracy of mid-cost optical particle counters for the ambient air monitoring of fine particles Vertical profile measurements for ammonia in a Japanese deciduous forest using denuder sampling technique: ammonia emissions near the forest floor Assessment of vehicle exhaust PM emissions using high-resolution on-road measurements in Seoul, Korea Satellite measurement data-based assessment of spatiotemporal characteristics of ultraviolet index (UVI) over the state of Johor, Malaysia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1