The air ionisation in Suceava Metropolitan Area

Alin Prisăcariu, D. Mihăilă, Petruț-Ionel Bistricean
{"title":"The air ionisation in Suceava Metropolitan Area","authors":"Alin Prisăcariu, D. Mihăilă, Petruț-Ionel Bistricean","doi":"10.47743/pesd2023171024","DOIUrl":null,"url":null,"abstract":": This study is the first of its kind, conducted for a city and its surroundings, in Romania. The air ionisation monitoring for Suceava Metropolitan Area (SvMA) was carried out with the PC Connectable Highly Accurate Air Ion Counter Tester COM-3200PRO II, in 34 points from SvMA (Suceava Metropolitan Area), in four time sequences of the year (January, March, July and November), in different parts of the day (morning, afternoon and evening), on active surfaces differentiated in properties (from anthropogenic to natural). The annual average value of the positive (n+) ion levels at the SvMA monitoring points was 576.6 ions/cm-3. The annual average of negative (n) ions at the monitoring points in SvMA in 2022 was 379.5 ions/cm-3. The study shows an annual regime of n-levels which has specifically a maximum in July (598.6 ions/cm-3) and an annual regime of n+, which has a minimum in the same month (415.3 ions/cm-3). The unipolarity coefficient (k) had a value of 1.52 for the whole of SvMA for the year 2022, ranging from 5.8 in January to 0.73 in July. The lowest k values were calculated for the observation points located in the rural localities from the vicinity of the urban perimeter of Suceava and for the natural ones from the","PeriodicalId":42850,"journal":{"name":"Present Environment and Sustainable Development","volume":"1 1","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Present Environment and Sustainable Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47743/pesd2023171024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GEOGRAPHY","Score":null,"Total":0}
引用次数: 0

Abstract

: This study is the first of its kind, conducted for a city and its surroundings, in Romania. The air ionisation monitoring for Suceava Metropolitan Area (SvMA) was carried out with the PC Connectable Highly Accurate Air Ion Counter Tester COM-3200PRO II, in 34 points from SvMA (Suceava Metropolitan Area), in four time sequences of the year (January, March, July and November), in different parts of the day (morning, afternoon and evening), on active surfaces differentiated in properties (from anthropogenic to natural). The annual average value of the positive (n+) ion levels at the SvMA monitoring points was 576.6 ions/cm-3. The annual average of negative (n) ions at the monitoring points in SvMA in 2022 was 379.5 ions/cm-3. The study shows an annual regime of n-levels which has specifically a maximum in July (598.6 ions/cm-3) and an annual regime of n+, which has a minimum in the same month (415.3 ions/cm-3). The unipolarity coefficient (k) had a value of 1.52 for the whole of SvMA for the year 2022, ranging from 5.8 in January to 0.73 in July. The lowest k values were calculated for the observation points located in the rural localities from the vicinity of the urban perimeter of Suceava and for the natural ones from the
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
苏西瓦大都市区的空气电离
这项研究是罗马尼亚第一次对一个城市及其周边地区进行此类研究。使用PC连接的高精度空气离子计数器COM-3200PRO II,在SvMA (Suceava Metropolitan Area)的34个点,在一年中的四个时间序列(1月,3月,7月和11月),在一天的不同部分(上午,下午和晚上),在不同性质的活动表面(从人为到自然)上进行空气电离监测。SvMA监测点n+年平均值为576.6个离子/cm-3。2022年SvMA监测点负(n)离子年平均值为379.5个离子/cm-3。研究表明,n水平的年变化规律在7月达到最大值(598.6个离子/cm-3), n+的年变化规律在同月达到最小值(415.3个离子/cm-3)。2022年整个SvMA的单极系数(k)为1.52,1月为5.8,7月为0.73。位于苏西瓦城市周边附近农村地区的观测点和位于苏西瓦城市周边地区的自然观测点的k值最低
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
28.60%
发文量
3
审稿时长
8 weeks
期刊最新文献
Assessment of leadership actions for Environmental Stewardship Enhancement in public schools The use of spectral techniques to monitor the vegetation status in a protected area in the Iasi county Sand winds effect on the degradation of photovoltaic modules in desert environments - PART I: Simulator design and Database creating Quantitative tools to assess climatic impact on energy consumption. Case study: Bucharest town area Walking where men walk: gendered politics of smallholder agriculture in Zimbabwe
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1