DETERMINATION OF CHLORHEXIDINE DIGLUCONATE IN DISINFECTANTS

S. Andreev, E. S. Belyaev, A. O. Ivanova, Elvina A. Novikova, A. Ishchenko
{"title":"DETERMINATION OF CHLORHEXIDINE DIGLUCONATE IN DISINFECTANTS","authors":"S. Andreev, E. S. Belyaev, A. O. Ivanova, Elvina A. Novikova, A. Ishchenko","doi":"10.6060/ivkkt20186108.5718","DOIUrl":null,"url":null,"abstract":"Chlorhexidine digluconate has been widely used in lenticular compositions, skin antiseptics and other ready-to-use disinfectants. This is due to its low toxicity, as well as a wide range of antimicrobial effects. A commonly used method for the analysis of commercially available chlorhexidine digluconate (usually available as a 20% aqueous solution) is high-performance liquid chromatography. In this article, the main methods of analysis used to determine chlorhexidine digluconate in disinfectants and skin antiseptics are considered. A new simple technique for the determination of chlorhexidine digluconate in technical products and disinfectants based on acid-base titration in alcohol-ketone is developed. It is shown that in this medium hydrochloric acid interacts with two nitrogen atoms of the chlorhexidine digluconate molecule. The end point of the titration is established by the transition of the blue color to green in the presence of bromophenol blue. The range of measured concentrations is from 0.1 to 2.0 mass%. The relative error of the method is 2.5% with the confidence probability P = 0.95. A comparison of the diode array detector and the charged aerosol detector for the determination of chlorhexidine digluconate has been performed. It is shown that a charged aerosol detector can be used to analyze chlorhexidine digluconate in cases where it is difficult to analyze with an ultraviolet or diode array detector. However, the sensitivity of the detector of charged aerosols is significantly lower than that of the diode matrix, and the linearity range is smaller. All methods were tested on model samples, as well as on samples of disinfectants, skin antiseptics, soaps and wipes with antibacterial effect.","PeriodicalId":45993,"journal":{"name":"Izvestiya Vysshikh Uchebnykh Zavedenii Khimiya i Khimicheskaya Tekhnologiya","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2018-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Izvestiya Vysshikh Uchebnykh Zavedenii Khimiya i Khimicheskaya Tekhnologiya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6060/ivkkt20186108.5718","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Chlorhexidine digluconate has been widely used in lenticular compositions, skin antiseptics and other ready-to-use disinfectants. This is due to its low toxicity, as well as a wide range of antimicrobial effects. A commonly used method for the analysis of commercially available chlorhexidine digluconate (usually available as a 20% aqueous solution) is high-performance liquid chromatography. In this article, the main methods of analysis used to determine chlorhexidine digluconate in disinfectants and skin antiseptics are considered. A new simple technique for the determination of chlorhexidine digluconate in technical products and disinfectants based on acid-base titration in alcohol-ketone is developed. It is shown that in this medium hydrochloric acid interacts with two nitrogen atoms of the chlorhexidine digluconate molecule. The end point of the titration is established by the transition of the blue color to green in the presence of bromophenol blue. The range of measured concentrations is from 0.1 to 2.0 mass%. The relative error of the method is 2.5% with the confidence probability P = 0.95. A comparison of the diode array detector and the charged aerosol detector for the determination of chlorhexidine digluconate has been performed. It is shown that a charged aerosol detector can be used to analyze chlorhexidine digluconate in cases where it is difficult to analyze with an ultraviolet or diode array detector. However, the sensitivity of the detector of charged aerosols is significantly lower than that of the diode matrix, and the linearity range is smaller. All methods were tested on model samples, as well as on samples of disinfectants, skin antiseptics, soaps and wipes with antibacterial effect.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
消毒剂中二光酸氯己定的测定
二光酸氯己定已广泛用于透镜组合物、皮肤防腐剂和其他即用消毒剂中。这是由于它的低毒性,以及广泛的抗菌作用。市售的二光酸氯己定(通常为20%水溶液)常用的分析方法是高效液相色谱法。本文介绍了消毒液和皮肤防腐剂中二光酸氯己定的主要分析方法。建立了用醇酮酸碱滴定法测定工业产品和消毒剂中二光酸氯己定含量的新方法。结果表明,在这种介质中,盐酸与二光酸氯己定分子的两个氮原子相互作用。在溴酚蓝存在的情况下,通过蓝色向绿色的转变来确定滴定的终点。测量浓度范围为0.1 ~ 2.0质量%。该方法的相对误差为2.5%,置信概率P = 0.95。对二极管阵列检测器和带电气溶胶检测器测定二光酸氯己定进行了比较。结果表明,在紫外或二极管阵列检测器难以分析的情况下,带电气溶胶检测器可用于分析二光酸氯己定。然而,探测器对带电气溶胶的灵敏度明显低于二极管矩阵,线性范围较小。所有方法均在模型样品以及具有抗菌作用的消毒剂、皮肤杀菌剂、肥皂和湿巾样品上进行了试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.40
自引率
44.40%
发文量
83
期刊最新文献
Mathematical modeling of deformation and relaxation processes of polymer yarn Study of integration of software applications into design process The significance of VKHUTEMAS in the development of theatrical culture in Russia of XX-XXI centuries Method of measuring fibers’ friction bending resistance Study of physical and mechanical properties of knitted fabrics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1