Non-residential water demand model validated with extensive measurements and surveys

E. J. Pieterse-Quirijns, E. Blokker, E. van der Blom, J. Vreeburg
{"title":"Non-residential water demand model validated with extensive measurements and surveys","authors":"E. J. Pieterse-Quirijns, E. Blokker, E. van der Blom, J. Vreeburg","doi":"10.5194/DWES-6-99-2013","DOIUrl":null,"url":null,"abstract":"Existing Dutch guidelines for the design of the drinking water and hot water system of nonresidential buildings are based on outdated assumptions on peak water demand or on unfounded assumptions on hot water demand. They generally overestimate peak demand values required for the design of an efficient and reliable water system. Recently, a procedure was developed based on the end-use model SIMDEUM to derive design-demand-equations for peak demand values of both cold and hot water during various time steps for several types and sizes of non-residential buildings, viz. offices, hotels and nursing homes. In this paper, the design-demand-equations are validated with measurements of cold and hot water patterns on a per second base and with surveys. The good correlation between the simulated water demand patterns and the measured patterns indicates that the basis of the design-demand-equations, the SIMDEUM simulated standardised buildings, is solid. Surveys were held to investigate whether the construction of the standardised buildings based on the dominant variable corresponds with practice. Surveys show that it is difficult to find relationships to equip the standardised buildings with users and appliances. However, the validation proves that with a proper estimation of the number of users and appliances in only the dominant functional room of the standardised buildings, SIMDEUM renders a realistic cold and hot water diurnal demand pattern. Furthermore, the new design-demand-equations based on these standardised buildings give a better prediction of the measured peak values for cold water flow than the existing guidelines. Moreover, the new design-demand-equations can predict hot water use well. In this paper it is illustrated that the new design-demand-equations lead to reliable and improved designs of building installations and water heater capacity, resulting in more hygienic and economical installations.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"80 1","pages":"99-114"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5194/DWES-6-99-2013","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drinking Water Engineering and Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5194/DWES-6-99-2013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 13

Abstract

Existing Dutch guidelines for the design of the drinking water and hot water system of nonresidential buildings are based on outdated assumptions on peak water demand or on unfounded assumptions on hot water demand. They generally overestimate peak demand values required for the design of an efficient and reliable water system. Recently, a procedure was developed based on the end-use model SIMDEUM to derive design-demand-equations for peak demand values of both cold and hot water during various time steps for several types and sizes of non-residential buildings, viz. offices, hotels and nursing homes. In this paper, the design-demand-equations are validated with measurements of cold and hot water patterns on a per second base and with surveys. The good correlation between the simulated water demand patterns and the measured patterns indicates that the basis of the design-demand-equations, the SIMDEUM simulated standardised buildings, is solid. Surveys were held to investigate whether the construction of the standardised buildings based on the dominant variable corresponds with practice. Surveys show that it is difficult to find relationships to equip the standardised buildings with users and appliances. However, the validation proves that with a proper estimation of the number of users and appliances in only the dominant functional room of the standardised buildings, SIMDEUM renders a realistic cold and hot water diurnal demand pattern. Furthermore, the new design-demand-equations based on these standardised buildings give a better prediction of the measured peak values for cold water flow than the existing guidelines. Moreover, the new design-demand-equations can predict hot water use well. In this paper it is illustrated that the new design-demand-equations lead to reliable and improved designs of building installations and water heater capacity, resulting in more hygienic and economical installations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
非住宅用水需求模型经过广泛的测量和调查验证
荷兰现有的非住宅建筑饮用水和热水系统设计指南是基于对峰值用水需求的过时假设或对热水需求的毫无根据的假设。他们通常高估了设计高效可靠的供水系统所需的峰值需求值。最近,基于最终用途模型SIMDEUM开发了一种程序,以推导出几种类型和大小的非住宅建筑(即办公室,酒店和养老院)在不同时间步长的冷热水峰值需求值的设计需求方程。本文通过以每秒为单位的冷热水模式测量和调查验证了设计-需求方程。模拟需水模式与实测模式之间的良好相关性表明,SIMDEUM模拟标准化建筑的设计-需水方程的基础是坚实的。对基于主导变量的标准化建筑的建设是否符合实际进行了调查。调查显示,很难找到为标准化建筑配备用户和设备的关系。然而,验证证明,通过对标准化建筑的主要功能房间的用户数量和设备数量的适当估计,SIMDEUM呈现出现实的冷热水日需求模式。此外,基于这些标准化建筑的新设计-需求方程比现有的指导方针更好地预测了冷水流量的测量峰值。此外,新的设计需求方程可以很好地预测热水的使用情况。本文说明,新的设计需求方程使建筑装置和热水器容量的设计更加可靠和改进,从而使建筑装置更加卫生和经济。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Drinking Water Engineering and Science
Drinking Water Engineering and Science Environmental Science-Water Science and Technology
CiteScore
3.90
自引率
0.00%
发文量
3
审稿时长
40 weeks
期刊最新文献
The evaluation of hydraulic reliability indices in water distribution networks under pipe failure conditions Technical note: Graph theory-based heuristics to aid in the implementation of optimized drinking water network sectorization Solar distillation of impure water from four different water sources under the southwestern Nigerian climate Sustainability characteristics of drinking water supply in the Netherlands Preparation of thin-film composite membranes supported with electrospun nanofibers for desalination by forward osmosis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1