A di-electrophoretic simulation procedure of iron-oxide micro-particle drug attachment system for leukemia treatment using COMSOL software: a potential treatment reference for LMICs.

IF 2.7 Q3 ENGINEERING, BIOMEDICAL Frontiers in medical technology Pub Date : 2023-10-12 eCollection Date: 2023-01-01 DOI:10.3389/fmedt.2023.1250964
Henry Fenekansi Kiwumulo, Haruna Muwonge, Charles Ibingira, Michael Lubwama, John Baptist Kirabira, Robert Tamale Ssekitoleko
{"title":"A di-electrophoretic simulation procedure of iron-oxide micro-particle drug attachment system for leukemia treatment using COMSOL software: a potential treatment reference for LMICs.","authors":"Henry Fenekansi Kiwumulo, Haruna Muwonge, Charles Ibingira, Michael Lubwama, John Baptist Kirabira, Robert Tamale Ssekitoleko","doi":"10.3389/fmedt.2023.1250964","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Leukemia encompasses various subtypes, each with unique characteristics and treatment approaches. The challenge lies in developing targeted therapies that can effectively address the specific genetic mutations or abnormalities associated with each subtype. Some leukemia cases may become resistant to existing treatments over time making them less susceptible to chemotherapy or other standard therapies.</p><p><strong>Objective: </strong>Developing new treatment strategies to overcome resistance is an ongoing challenge particularly in Low and Middle Income Countries (LMICs). Computational studies using COMSOL software could provide an economical, fast and resourceful approach to the treatment of complicated cancers like leukemia.</p><p><strong>Methods: </strong>Using COMSOL Multiphysics software, a continuous flow microfluidic device capable of delivering anti-leukemia drugs to early-stage leukemia cells has been computationally modeled using dielectrophoresis (DEP).</p><p><strong>Results: </strong>The cell size difference enabled the micro-particle drug attachment to the leukemia cells using hydrodynamic focusing from the dielectrophoretic force. This point of care application produced a low voltage from numerically calculated electrical field and flow speed simulations.</p><p><strong>Conclusion: </strong>Therefore, such a dielectrophoretic low voltage application model can be used as a computational treatment reference for early-stage leukemia cells with an approximate size of 5 μm.</p>","PeriodicalId":94015,"journal":{"name":"Frontiers in medical technology","volume":"5 ","pages":"1250964"},"PeriodicalIF":2.7000,"publicationDate":"2023-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10602814/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in medical technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fmedt.2023.1250964","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Leukemia encompasses various subtypes, each with unique characteristics and treatment approaches. The challenge lies in developing targeted therapies that can effectively address the specific genetic mutations or abnormalities associated with each subtype. Some leukemia cases may become resistant to existing treatments over time making them less susceptible to chemotherapy or other standard therapies.

Objective: Developing new treatment strategies to overcome resistance is an ongoing challenge particularly in Low and Middle Income Countries (LMICs). Computational studies using COMSOL software could provide an economical, fast and resourceful approach to the treatment of complicated cancers like leukemia.

Methods: Using COMSOL Multiphysics software, a continuous flow microfluidic device capable of delivering anti-leukemia drugs to early-stage leukemia cells has been computationally modeled using dielectrophoresis (DEP).

Results: The cell size difference enabled the micro-particle drug attachment to the leukemia cells using hydrodynamic focusing from the dielectrophoretic force. This point of care application produced a low voltage from numerically calculated electrical field and flow speed simulations.

Conclusion: Therefore, such a dielectrophoretic low voltage application model can be used as a computational treatment reference for early-stage leukemia cells with an approximate size of 5 μm.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用COMSOL软件的氧化铁微粒药物附着系统用于白血病治疗的双电泳模拟程序:LMIC的潜在治疗参考。
背景:白血病包括各种亚型,每种亚型都有其独特的特征和治疗方法。挑战在于开发能够有效解决与每种亚型相关的特定基因突变或异常的靶向疗法。随着时间的推移,一些白血病患者可能会对现有的治疗方法产生耐药性,从而降低他们对化疗或其他标准治疗的敏感性。目标:制定新的治疗策略以克服耐药性是一项持续的挑战,尤其是在中低收入国家。使用COMSOL软件进行的计算研究可以为治疗白血病等复杂癌症提供一种经济、快速、足智多谋的方法。方法:利用COMSOL Multiphysics软件,利用介电泳(DEP)对一种能够向早期白血病细胞输送抗白血病药物的连续流微流体装置进行了计算建模。这种护理点应用通过数值计算的电场和流速模拟产生了低电压。结论:因此,这种介电泳低电压应用模型可以作为大小约为5的早期白血病细胞的计算治疗参考 μm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.70
自引率
0.00%
发文量
0
审稿时长
13 weeks
期刊最新文献
Open-loop narrowband magnetic particle imaging based on mixed-frequency harmonic magnetization response. A prototype photoplethysmography-based cuffless device shows promising results in tracking changes in blood pressure. Motion artifact variability in biomagnetic wearable devices. Advancements in sarcopenia diagnosis: from imaging techniques to non-radiation assessments. Towards non-invasive imaging through spinal-cord generated magnetic fields.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1