How Does Target Lesion Selection Affect RECIST? A Computer Simulation Study.

IF 7 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Investigative Radiology Pub Date : 2024-06-01 Epub Date: 2023-11-03 DOI:10.1097/RLI.0000000000001045
Teresa M Tareco Bucho, Renaud L M Tissier, Kevin B W Groot Lipman, Zuhir Bodalal, Andrea Delli Pizzi, Thi Dan Linh Nguyen-Kim, Regina G H Beets-Tan, Stefano Trebeschi
{"title":"How Does Target Lesion Selection Affect RECIST? A Computer Simulation Study.","authors":"Teresa M Tareco Bucho, Renaud L M Tissier, Kevin B W Groot Lipman, Zuhir Bodalal, Andrea Delli Pizzi, Thi Dan Linh Nguyen-Kim, Regina G H Beets-Tan, Stefano Trebeschi","doi":"10.1097/RLI.0000000000001045","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Response Evaluation Criteria in Solid Tumors (RECIST) is grounded on the assumption that target lesion selection is objective and representative of the change in total tumor burden (TTB) during therapy. A computer simulation model was designed to challenge this assumption, focusing on a particular aspect of subjectivity: target lesion selection.</p><p><strong>Materials and methods: </strong>Disagreement among readers and the disagreement between individual reader measurements and TTB were analyzed as a function of the total number of lesions, affected organs, and lesion growth.</p><p><strong>Results: </strong>Disagreement rises when the number of lesions increases, when lesions are concentrated on a few organs, and when lesion growth borders the thresholds of progressive disease and partial response. There is an intrinsic methodological error in the estimation of TTB via RECIST 1.1, which depends on the number of lesions and their distributions. For example, for a fixed number of lesions at 5 and 15, distributed over a maximum of 4 organs, the error rates are observed to be 7.8% and 17.3%, respectively.</p><p><strong>Conclusions: </strong>Our results demonstrate that RECIST can deliver an accurate estimate of TTB in localized disease, but fails in cases of distal metastases and multiple organ involvement. This is worsened by the \"selection of the largest lesions,\" which introduces a bias that makes it hardly possible to perform an accurate estimate of the TTB. Including more (if not all) lesions in the quantitative analysis of tumor burden is desirable.</p>","PeriodicalId":14486,"journal":{"name":"Investigative Radiology","volume":null,"pages":null},"PeriodicalIF":7.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RLI.0000000000001045","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Response Evaluation Criteria in Solid Tumors (RECIST) is grounded on the assumption that target lesion selection is objective and representative of the change in total tumor burden (TTB) during therapy. A computer simulation model was designed to challenge this assumption, focusing on a particular aspect of subjectivity: target lesion selection.

Materials and methods: Disagreement among readers and the disagreement between individual reader measurements and TTB were analyzed as a function of the total number of lesions, affected organs, and lesion growth.

Results: Disagreement rises when the number of lesions increases, when lesions are concentrated on a few organs, and when lesion growth borders the thresholds of progressive disease and partial response. There is an intrinsic methodological error in the estimation of TTB via RECIST 1.1, which depends on the number of lesions and their distributions. For example, for a fixed number of lesions at 5 and 15, distributed over a maximum of 4 organs, the error rates are observed to be 7.8% and 17.3%, respectively.

Conclusions: Our results demonstrate that RECIST can deliver an accurate estimate of TTB in localized disease, but fails in cases of distal metastases and multiple organ involvement. This is worsened by the "selection of the largest lesions," which introduces a bias that makes it hardly possible to perform an accurate estimate of the TTB. Including more (if not all) lesions in the quantitative analysis of tumor burden is desirable.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
靶病变选择如何影响RECIST?计算机模拟研究。
目的:实体瘤疗效评估标准(RECIST)基于这样一种假设,即靶病变的选择是客观的,并能代表治疗期间肿瘤总负荷(TTB)的变化。设计了一个计算机模拟模型来挑战这一假设,重点关注主观性的一个特定方面:目标病变的选择。材料和方法:将读者之间的分歧以及个体读者测量值和TTB之间的分歧作为病变总数、受影响器官和病变生长的函数进行分析。结果:当病变数量增加时,当病变集中在少数器官时,以及当病变生长接近进行性疾病和部分反应的阈值时,分歧加剧。通过RECIST 1.1估计TTB存在固有的方法学错误,这取决于病变的数量及其分布。例如,对于5个和15个固定数量的病变,分布在最多4个器官上,观察到错误率分别为7.8%和17.3%。结论:我们的研究结果表明,RECIST可以在局部疾病中准确估计TTB,但在远端转移和多器官受累的情况下失败。这种情况因“选择最大的病变”而恶化,这引入了一种偏差,使得很难对TTB进行准确估计。在肿瘤负荷的定量分析中包括更多(如果不是全部的话)病变是可取的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Investigative Radiology
Investigative Radiology 医学-核医学
CiteScore
15.10
自引率
16.40%
发文量
188
审稿时长
4-8 weeks
期刊介绍: Investigative Radiology publishes original, peer-reviewed reports on clinical and laboratory investigations in diagnostic imaging, the diagnostic use of radioactive isotopes, computed tomography, positron emission tomography, magnetic resonance imaging, ultrasound, digital subtraction angiography, and related modalities. Emphasis is on early and timely publication. Primarily research-oriented, the journal also includes a wide variety of features of interest to clinical radiologists.
期刊最新文献
Editorial: Hot Topics in Diagnostic Imaging-Encompassing Advances in MR, Photon-Counting CT, and Ultrasound. Implementation of an AI Algorithm in Clinical Practice to Reduce Missed Incidental Pulmonary Embolisms on Chest CT and Its Impact on Short-Term Survival. Tungsten-Based Contrast Agent for Photon-Counting Detector CT Angiography in Calcified Coronaries: Comparison to Iodine in a Cardiovascular Phantom. Image Quality and Radiation Exposure in Abdominal Angiography: A Head-to-Head Comparison of Conventional Detector-Dose-Driven Versus Contrast-to-Noise Ratio-Driven Exposure Control at Various Source-to-Image Receptor Distances and Collimations in a Pilot Phantom and Animal Study. Countering Calcium Blooming With Personalized Contrast Media Injection Protocols: The 1-2-3 Rule for Photon-Counting Detector CCTA.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1