Development and evaluation of an integrated liver nodule diagnostic method by combining the liver segment division and lesion localization/classification models for enhanced focal liver lesion detection.

IF 1.7 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Radiological Physics and Technology Pub Date : 2024-03-01 Epub Date: 2023-11-02 DOI:10.1007/s12194-023-00753-y
Tomomi Takenaga, Shouhei Hanaoka, Yukihiro Nomura, Takahiro Nakao, Hisaichi Shibata, Soichiro Miki, Takeharu Yoshikawa, Naoto Hayashi, Osamu Abe
{"title":"Development and evaluation of an integrated liver nodule diagnostic method by combining the liver segment division and lesion localization/classification models for enhanced focal liver lesion detection.","authors":"Tomomi Takenaga, Shouhei Hanaoka, Yukihiro Nomura, Takahiro Nakao, Hisaichi Shibata, Soichiro Miki, Takeharu Yoshikawa, Naoto Hayashi, Osamu Abe","doi":"10.1007/s12194-023-00753-y","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of the study was to develop a liver nodule diagnostic method that accurately localizes and classifies focal liver lesions and identifies the specific liver segments in which they reside by integrating a liver segment division algorithm using a four-dimensional (4D) fully convolutional residual network (FC-ResNet) with a localization and classification model. We retrospectively collected data and divided 106 gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid-enhanced magnetic resonance examinations into Case-sets 1, 2, and 3. A liver segment division algorithm was developed using a 4D FC-ResNet and trained with semi-automatically created silver-standard annotations; performance was evaluated using manually created gold-standard annotations by calculating the Dice scores for each liver segment. The performance of the liver nodule diagnostic method was assessed by comparing the results with those of the original radiology reports. The mean Dice score between the output of the liver segment division model and the gold standard was 0.643 for Case-set 2 (normal liver contours) and 0.534 for Case-set 1 (deformed liver contours). Among the 64 lesions in Case-set 3, the diagnostic method localized 37 lesions, classified 33 lesions, and identified the liver segments for 30 lesions. A total of 28 lesions were true positives, matching the original radiology reports. The liver nodule diagnostic method, which integrates a liver segment division algorithm with a lesion localization and classification model, exhibits great potential for localizing and classifying focal liver lesions and identifying the liver segments in which they reside. Further improvements and validation using larger sample sizes will enhance its performance and clinical applicability.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-023-00753-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/2 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of the study was to develop a liver nodule diagnostic method that accurately localizes and classifies focal liver lesions and identifies the specific liver segments in which they reside by integrating a liver segment division algorithm using a four-dimensional (4D) fully convolutional residual network (FC-ResNet) with a localization and classification model. We retrospectively collected data and divided 106 gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid-enhanced magnetic resonance examinations into Case-sets 1, 2, and 3. A liver segment division algorithm was developed using a 4D FC-ResNet and trained with semi-automatically created silver-standard annotations; performance was evaluated using manually created gold-standard annotations by calculating the Dice scores for each liver segment. The performance of the liver nodule diagnostic method was assessed by comparing the results with those of the original radiology reports. The mean Dice score between the output of the liver segment division model and the gold standard was 0.643 for Case-set 2 (normal liver contours) and 0.534 for Case-set 1 (deformed liver contours). Among the 64 lesions in Case-set 3, the diagnostic method localized 37 lesions, classified 33 lesions, and identified the liver segments for 30 lesions. A total of 28 lesions were true positives, matching the original radiology reports. The liver nodule diagnostic method, which integrates a liver segment division algorithm with a lesion localization and classification model, exhibits great potential for localizing and classifying focal liver lesions and identifying the liver segments in which they reside. Further improvements and validation using larger sample sizes will enhance its performance and clinical applicability.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过结合肝段划分和病变定位/分类模型,开发和评估用于增强局灶性肝病变检测的综合性肝结节诊断方法。
该研究的目的是开发一种肝结节诊断方法,通过将使用四维(4D)全卷积残差网络(FC-ResNet)的肝段分割算法与定位和分类模型相结合,准确定位和分类局灶性肝损伤,并识别其所在的特定肝段。我们回顾性收集了数据,并将106例钆乙氧基苄基二亚乙基三胺五乙酸增强磁共振检查分为病例集1、2和3。使用4D FC ResNet开发了肝段分割算法,并使用半自动创建的银标准注释进行训练;通过计算每个肝段的Dice评分,使用手动创建的金标准注释来评估性能。通过将结果与原始放射学报告的结果进行比较来评估肝结节诊断方法的性能。肝段分割模型的输出与金标准之间的平均Dice评分对于病例集2(正常肝轮廓)为0.643,对于病例集1(变形肝轮廓)则为0.534。在病例组3的64个病变中,诊断方法定位了37个病变,对33个病变进行了分类,并确定了30个病变的肝段。共有28处病变为真阳性,与原始放射学报告相匹配。肝结节诊断方法将肝节段分割算法与病变定位和分类模型相结合,在定位和分类局灶性肝病变以及识别其所在的肝节段方面显示出巨大的潜力。使用更大样本量的进一步改进和验证将提高其性能和临床适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Radiological Physics and Technology
Radiological Physics and Technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
12.50%
发文量
40
期刊介绍: The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.
期刊最新文献
Effectiveness of the air-gap method for reducing radiation dose in neonate CT examinations. Optimization of image shoot timing for cerebral veins 3D-digital subtraction angiography by interventional angiography systems. Anomaly detection scheme for lung CT images using vector quantized variational auto-encoder with support vector data description. Deep learning-based approach for acquisition time reduction in ventilation SPECT in patients after lung transplantation. Visualization of X-ray fields, overlaps, and over-beaming on surface of the head in spiral computed tomography using computer-aided design-based X-ray beam modeling.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1