{"title":"Effectiveness and safety of a cement-on-cement removal system for hip and knee arthroplasty revision surgery.","authors":"Miguel Tovar-Bazaga, David Sáez-Martínez, Álvaro Auñón, Felipe López-Oliva, Emilio Calvo","doi":"10.52628/89.2.11562","DOIUrl":null,"url":null,"abstract":"<p><p>Cement removal during hip or knee arthroplasty revision is challenging and not exempt of complications. Cement-on-cement procedure is among techniques developed to safe removal of cement from bone, and it could be a realistic solution. This cement-on-cement devices can provide advantages in removing bone cement during hip and knee arthroplasty septic and non-septic revision surgeries, and can be regarded as an effective and safe alternative. We present our experience using the cement-on-cement technique in 34 cases between 2010 and 2021, including revision surgeries for 20 knee and 14 hip arthroplasties. In 3 out of 34 cases the technique failed, with a success of 91%. Mean surgical time was 2.77 (SD 0.93) hours and blood transfusion was required in 23 cases. Success was achieved in every aseptic case. Of all patients, 60% were septic cases. Infection was considered to be eradicated in 70% (14/20) of patients with a septic revision. Cement-on-cement is a safe and effective alternative for cement removal during hip and knee arthroplasty revision. Level of evidence: III, retrospective case series.</p>","PeriodicalId":7018,"journal":{"name":"Acta orthopaedica Belgica","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica Belgica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.52628/89.2.11562","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Cement removal during hip or knee arthroplasty revision is challenging and not exempt of complications. Cement-on-cement procedure is among techniques developed to safe removal of cement from bone, and it could be a realistic solution. This cement-on-cement devices can provide advantages in removing bone cement during hip and knee arthroplasty septic and non-septic revision surgeries, and can be regarded as an effective and safe alternative. We present our experience using the cement-on-cement technique in 34 cases between 2010 and 2021, including revision surgeries for 20 knee and 14 hip arthroplasties. In 3 out of 34 cases the technique failed, with a success of 91%. Mean surgical time was 2.77 (SD 0.93) hours and blood transfusion was required in 23 cases. Success was achieved in every aseptic case. Of all patients, 60% were septic cases. Infection was considered to be eradicated in 70% (14/20) of patients with a septic revision. Cement-on-cement is a safe and effective alternative for cement removal during hip and knee arthroplasty revision. Level of evidence: III, retrospective case series.