The ceramic coated implant (CCI). Evolution total ankle replacements: a retrospective analysis of 40 ankles with 8 years follow-up.

IF 0.5 4区 医学 Q4 ORTHOPEDICS Acta orthopaedica Belgica Pub Date : 2023-09-01 DOI:10.52628/89.3.11585
S Kormi, H Koivu, I Kohonen, K Mäkelä, H Tiusanen, M Saltychev
{"title":"The ceramic coated implant (CCI). Evolution total ankle replacements: a retrospective analysis of 40 ankles with 8 years follow-up.","authors":"S Kormi, H Koivu, I Kohonen, K Mäkelä, H Tiusanen, M Saltychev","doi":"10.52628/89.3.11585","DOIUrl":null,"url":null,"abstract":"<p><p>Diminutive data is available on the outcome of several previously used total ankle replacement implants. The purpose of this study was to investigate the medium-term functional and radiological outcome and implant survival of the CCI Evolution implant. Consecutive series of 40 ankles operated in our hospital with primary TAR using the CCI Evolution implant in 2010-2013 were available for follow-up. The prospective clinical and radiographic data including the Kofoed score, subjective satisfaction and standard radiographs were collected preoperatively and at fixed time-points postoperatively. A CT was obtained in cases where osteolysis or loosening were suspected. The improvement of the Kofoed score and subjective satisfaction were statistically significant (p<0.0001). The implant survival was 97% (95% confidence interval (CI) 81%-100 %) at 5 years, and 81 % (95% confidence interval (CI) 60 %-92%) at 8 years. There were altogether 25 (64%) complications. Overall revision rate was 28% and failure rate 13%. The CCI implant outcome was not acceptable. The malposition of prosthetic components, subsidence, and peri-implant osteolysis were recorded often. Although the patient reported outcome measures improved, mostly due to positive changes in pain severity, overall revision and failure rates were high and comparable with previous findings of the CCI implant.</p>","PeriodicalId":7018,"journal":{"name":"Acta orthopaedica Belgica","volume":"89 3","pages":"515-524"},"PeriodicalIF":0.5000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica Belgica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.52628/89.3.11585","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Diminutive data is available on the outcome of several previously used total ankle replacement implants. The purpose of this study was to investigate the medium-term functional and radiological outcome and implant survival of the CCI Evolution implant. Consecutive series of 40 ankles operated in our hospital with primary TAR using the CCI Evolution implant in 2010-2013 were available for follow-up. The prospective clinical and radiographic data including the Kofoed score, subjective satisfaction and standard radiographs were collected preoperatively and at fixed time-points postoperatively. A CT was obtained in cases where osteolysis or loosening were suspected. The improvement of the Kofoed score and subjective satisfaction were statistically significant (p<0.0001). The implant survival was 97% (95% confidence interval (CI) 81%-100 %) at 5 years, and 81 % (95% confidence interval (CI) 60 %-92%) at 8 years. There were altogether 25 (64%) complications. Overall revision rate was 28% and failure rate 13%. The CCI implant outcome was not acceptable. The malposition of prosthetic components, subsidence, and peri-implant osteolysis were recorded often. Although the patient reported outcome measures improved, mostly due to positive changes in pain severity, overall revision and failure rates were high and comparable with previous findings of the CCI implant.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
陶瓷涂层植入物(CCI)。进化型全踝关节置换术:对40个踝关节进行8年随访的回顾性分析。
关于先前使用的几种全踝关节置换植入物的结果,可以获得越来越少的数据。本研究的目的是研究CCI Evolution植入物的中期功能和放射学结果以及植入物的存活率。2010-2013年,我们医院连续对40个脚踝进行了原发性TAR手术,使用CCI Evolution植入物进行了随访。术前和术后固定时间点收集前瞻性临床和放射学数据,包括Kofoed评分、主观满意度和标准x线片。对怀疑有骨溶解或松动的病例进行CT检查。Kofoed评分和主观满意度的改善具有统计学意义(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Acta orthopaedica Belgica
Acta orthopaedica Belgica 医学-整形外科
CiteScore
0.70
自引率
0.00%
发文量
58
审稿时长
4-8 weeks
期刊介绍: Information not localized
期刊最新文献
3D quantitative CT study to assess rotator cuff muscle fatty infiltration. Alkaptonuric Ochronosis: A case-based review. Chronic regional pain syndrome following calcaneal fractures: what causes it and how may Vitamin C aid? Clinical Significance of Arthroscopic Debridement, Trapeziectomy, and Joint Replacement for Basilar Thumb Joint Arthritis: A Meta-analysis of Pain Score Improvements. Cost analysis of total knee arthroplasty surgeries in Turkey.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1