John K Leypoldt, Jorge Echeverri, Kai Harenski, Kuljinder Singh
{"title":"Predictions of Serum Phosphate Concentration during Continuous Renal Replacement Therapy Using a Steady-State Mass Balance Model.","authors":"John K Leypoldt, Jorge Echeverri, Kai Harenski, Kuljinder Singh","doi":"10.1159/000533322","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Hypophosphatemia is common during continuous renal replacement therapy (CRRT), but serum phosphate levels can potentially be maintained during treatment by either intravenous phosphate supplementation or addition of phosphate to renal replacement therapy (RRT) solutions.</p><p><strong>Methods: </strong>We developed a steady-state phosphate mass balance model to assess the effects of CRRT dose on serum phosphate concentration when using both phosphate-free and phosphate-containing RRT solutions, with emphasis on low CRRT doses.</p><p><strong>Results: </strong>The model predicted that measurements of serum phosphate concentration prior to (initial) and during CRRT (final) together with clinical data on CRRT dose, treatment duration, and phosphate supplementation can determine model patient parameters, that is, both the initial generation rate and clearance of phosphate prior to CRRT. Model parameters were then calculated from average patient data reported in several previous publications with a standard or high CRRT dose. Using representative model parameters for typical patients, predictions were then made of the effect of low CRRT dose on the change in serum phosphate levels after implementation of CRRT. The model predicted that CRRT at a low dose using phosphate-free RRT solutions will limit, but not eliminate, the incidence of hypophosphatemia. Further, the model predicted that CRRT at a low dose will have virtually no influence on the incidence of hyperphosphatemia when using phosphate-containing RRT solutions.</p><p><strong>Conclusions: </strong>This report identifies the clinical measurements to be used with the proposed model for individualizing the CRRT dose and RRT phosphate concentration to maintain serum phosphate concentrations in a desired range.</p>","PeriodicalId":8953,"journal":{"name":"Blood Purification","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Purification","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000533322","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Hypophosphatemia is common during continuous renal replacement therapy (CRRT), but serum phosphate levels can potentially be maintained during treatment by either intravenous phosphate supplementation or addition of phosphate to renal replacement therapy (RRT) solutions.
Methods: We developed a steady-state phosphate mass balance model to assess the effects of CRRT dose on serum phosphate concentration when using both phosphate-free and phosphate-containing RRT solutions, with emphasis on low CRRT doses.
Results: The model predicted that measurements of serum phosphate concentration prior to (initial) and during CRRT (final) together with clinical data on CRRT dose, treatment duration, and phosphate supplementation can determine model patient parameters, that is, both the initial generation rate and clearance of phosphate prior to CRRT. Model parameters were then calculated from average patient data reported in several previous publications with a standard or high CRRT dose. Using representative model parameters for typical patients, predictions were then made of the effect of low CRRT dose on the change in serum phosphate levels after implementation of CRRT. The model predicted that CRRT at a low dose using phosphate-free RRT solutions will limit, but not eliminate, the incidence of hypophosphatemia. Further, the model predicted that CRRT at a low dose will have virtually no influence on the incidence of hyperphosphatemia when using phosphate-containing RRT solutions.
Conclusions: This report identifies the clinical measurements to be used with the proposed model for individualizing the CRRT dose and RRT phosphate concentration to maintain serum phosphate concentrations in a desired range.
期刊介绍:
Practical information on hemodialysis, hemofiltration, peritoneal dialysis and apheresis is featured in this journal. Recognizing the critical importance of equipment and procedures, particular emphasis has been placed on reports, drawn from a wide range of fields, describing technical advances and improvements in methodology. Papers reflect the search for cost-effective solutions which increase not only patient survival but also patient comfort and disease improvement through prevention or correction of undesirable effects. Advances in vascular access and blood anticoagulation, problems associated with exposure of blood to foreign surfaces and acute-care nephrology, including continuous therapies, also receive attention. Nephrologists, internists, intensivists and hospital staff involved in dialysis, apheresis and immunoadsorption for acute and chronic solid organ failure will find this journal useful and informative. ''Blood Purification'' also serves as a platform for multidisciplinary experiences involving nephrologists, cardiologists and critical care physicians in order to expand the level of interaction between different disciplines and specialities.