Dorothy A Thompson, Eszter Mikó-Baráth, Sharon E Hardy, Gábor Jandó, Martin Shaw, Ruth Hamilton
{"title":"ISCEV standard pattern reversal VEP development: paediatric reference limits from 649 healthy subjects.","authors":"Dorothy A Thompson, Eszter Mikó-Baráth, Sharon E Hardy, Gábor Jandó, Martin Shaw, Ruth Hamilton","doi":"10.1007/s10633-023-09952-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To establish the extent of agreement for ISCEV standard reference pattern reversal VEPs (prVEPs) acquired at three European centres, to determine any effect of sex, and to establish reference intervals from birth to adolescence.</p><p><strong>Methods: </strong>PrVEPs were recorded from healthy reference infants and children, aged 2 weeks to 16 years, from three centres using closely matched but non-identical protocols. Amplitudes and peak times were modelled with orthogonal quadratic and sigmoidal curves, respectively, and two-sided limits, 2.5th and 97.5th centiles, estimated using nonlinear quantile Bayesian regression. Data were compared by centre and by sex using median quantile confidence intervals. The 'critical age', i.e. age at which P100 peak time ceased to shorten, was calculated.</p><p><strong>Results: </strong>Data from the three centres were adequately comparable. Sex differences were not clinically meaningful. The pooled data showed rapid drops in P100 peak time which stabilised by 27 and by 34 weeks for large and small check widths, respectively. Post-critical-age reference limits were 87-115 ms and 96-131 ms for large and small check widths, respectively. Amplitudes varied markedly and reference limits for all ages were 5-57 μV and 3.5-56 μV for large and small check widths, respectively.</p><p><strong>Conclusions: </strong>PrVEP reference data could be combined despite some methodology differences within the tolerances of the ISCEV VEP Standard, supporting the clinical benefit of ISCEV Standards. Comparison with historical data is hampered by lack of minimum reporting guidelines. The reference data presented here could be validated or transformed for use elsewhere.</p>","PeriodicalId":11207,"journal":{"name":"Documenta Ophthalmologica","volume":" ","pages":"147-164"},"PeriodicalIF":2.6000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10638119/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Documenta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10633-023-09952-9","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To establish the extent of agreement for ISCEV standard reference pattern reversal VEPs (prVEPs) acquired at three European centres, to determine any effect of sex, and to establish reference intervals from birth to adolescence.
Methods: PrVEPs were recorded from healthy reference infants and children, aged 2 weeks to 16 years, from three centres using closely matched but non-identical protocols. Amplitudes and peak times were modelled with orthogonal quadratic and sigmoidal curves, respectively, and two-sided limits, 2.5th and 97.5th centiles, estimated using nonlinear quantile Bayesian regression. Data were compared by centre and by sex using median quantile confidence intervals. The 'critical age', i.e. age at which P100 peak time ceased to shorten, was calculated.
Results: Data from the three centres were adequately comparable. Sex differences were not clinically meaningful. The pooled data showed rapid drops in P100 peak time which stabilised by 27 and by 34 weeks for large and small check widths, respectively. Post-critical-age reference limits were 87-115 ms and 96-131 ms for large and small check widths, respectively. Amplitudes varied markedly and reference limits for all ages were 5-57 μV and 3.5-56 μV for large and small check widths, respectively.
Conclusions: PrVEP reference data could be combined despite some methodology differences within the tolerances of the ISCEV VEP Standard, supporting the clinical benefit of ISCEV Standards. Comparison with historical data is hampered by lack of minimum reporting guidelines. The reference data presented here could be validated or transformed for use elsewhere.
期刊介绍:
Documenta Ophthalmologica is an official publication of the International Society for Clinical Electrophysiology of Vision. The purpose of the journal is to promote the understanding and application of clinical electrophysiology of vision. Documenta Ophthalmologica will publish reviews, research articles, technical notes, brief reports and case studies which inform the readers about basic and clinical sciences related to visual electrodiagnosis and means to improve diagnosis and clinical management of patients using visual electrophysiology. Studies may involve animals or humans. In either case appropriate care must be taken to follow the Declaration of Helsinki for human subject or appropriate humane standards of animal care (e.g., the ARVO standards on Animal Care and Use).