Ojukwu Chidiebele Petronilla, Ezeigwe Anne Uruchi, Ezeigwe Chukwudi Francis, Ugwuonye Chioma Linda
{"title":"Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments.","authors":"Ojukwu Chidiebele Petronilla, Ezeigwe Anne Uruchi, Ezeigwe Chukwudi Francis, Ugwuonye Chioma Linda","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of the study was to determine the intra- and inter-rater reliability of palpation technique, digital calipers, and diastometer, as well as their concurrent validity against ultrasound imaging.</p><p><strong>Methods: </strong>Ninety consenting parous women (20-45 years), recruited from a postnatal clinic in Enugu, Nigeria, participated in this observational study. Two physiotherapists and a sonographer measured their inter rectus distance at the level of the umbilicus, 4.5 cm above and below it, respectively, using each of the four modalities. The intra-rater measurements were taken at a week's interval. Data were analyzed with descriptive and inferential statistics of intraclass correlation coefficient and paired samples T-test, at an alpha level set at <i>P</i> < 0.05.</p><p><strong>Results: </strong>It showed the palpation technique (r = 0.749-0.967 and 0.658-0.917), digital calipers (r=0.750-0.955 and 0.685-0.904), and diastometer (r=0.762-0.958 and 0.471-0.902) demonstrated good inter- and intra-rater reliability. The concurrent validity of the palpation technique, digital calipers, and diastometer against the USI was poor at all three reference points.</p><p><strong>Conclusion: </strong>Palpation technique, digital calipers, and diastometer are reliable tools but not valid substitutes to ultrasound imaging for the clinical measurement of diastasis rectus abdominis.</p>","PeriodicalId":47093,"journal":{"name":"International Journal of Health Sciences-IJHS","volume":"17 6","pages":"6-14"},"PeriodicalIF":2.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10624799/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Health Sciences-IJHS","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: The aim of the study was to determine the intra- and inter-rater reliability of palpation technique, digital calipers, and diastometer, as well as their concurrent validity against ultrasound imaging.
Methods: Ninety consenting parous women (20-45 years), recruited from a postnatal clinic in Enugu, Nigeria, participated in this observational study. Two physiotherapists and a sonographer measured their inter rectus distance at the level of the umbilicus, 4.5 cm above and below it, respectively, using each of the four modalities. The intra-rater measurements were taken at a week's interval. Data were analyzed with descriptive and inferential statistics of intraclass correlation coefficient and paired samples T-test, at an alpha level set at P < 0.05.
Results: It showed the palpation technique (r = 0.749-0.967 and 0.658-0.917), digital calipers (r=0.750-0.955 and 0.685-0.904), and diastometer (r=0.762-0.958 and 0.471-0.902) demonstrated good inter- and intra-rater reliability. The concurrent validity of the palpation technique, digital calipers, and diastometer against the USI was poor at all three reference points.
Conclusion: Palpation technique, digital calipers, and diastometer are reliable tools but not valid substitutes to ultrasound imaging for the clinical measurement of diastasis rectus abdominis.