Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments.

IF 2 Q2 MEDICINE, GENERAL & INTERNAL International Journal of Health Sciences-IJHS Pub Date : 2023-11-01
Ojukwu Chidiebele Petronilla, Ezeigwe Anne Uruchi, Ezeigwe Chukwudi Francis, Ugwuonye Chioma Linda
{"title":"Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments.","authors":"Ojukwu Chidiebele Petronilla,&nbsp;Ezeigwe Anne Uruchi,&nbsp;Ezeigwe Chukwudi Francis,&nbsp;Ugwuonye Chioma Linda","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of the study was to determine the intra- and inter-rater reliability of palpation technique, digital calipers, and diastometer, as well as their concurrent validity against ultrasound imaging.</p><p><strong>Methods: </strong>Ninety consenting parous women (20-45 years), recruited from a postnatal clinic in Enugu, Nigeria, participated in this observational study. Two physiotherapists and a sonographer measured their inter rectus distance at the level of the umbilicus, 4.5 cm above and below it, respectively, using each of the four modalities. The intra-rater measurements were taken at a week's interval. Data were analyzed with descriptive and inferential statistics of intraclass correlation coefficient and paired samples T-test, at an alpha level set at <i>P</i> < 0.05.</p><p><strong>Results: </strong>It showed the palpation technique (r = 0.749-0.967 and 0.658-0.917), digital calipers (r=0.750-0.955 and 0.685-0.904), and diastometer (r=0.762-0.958 and 0.471-0.902) demonstrated good inter- and intra-rater reliability. The concurrent validity of the palpation technique, digital calipers, and diastometer against the USI was poor at all three reference points.</p><p><strong>Conclusion: </strong>Palpation technique, digital calipers, and diastometer are reliable tools but not valid substitutes to ultrasound imaging for the clinical measurement of diastasis rectus abdominis.</p>","PeriodicalId":47093,"journal":{"name":"International Journal of Health Sciences-IJHS","volume":"17 6","pages":"6-14"},"PeriodicalIF":2.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10624799/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Health Sciences-IJHS","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The aim of the study was to determine the intra- and inter-rater reliability of palpation technique, digital calipers, and diastometer, as well as their concurrent validity against ultrasound imaging.

Methods: Ninety consenting parous women (20-45 years), recruited from a postnatal clinic in Enugu, Nigeria, participated in this observational study. Two physiotherapists and a sonographer measured their inter rectus distance at the level of the umbilicus, 4.5 cm above and below it, respectively, using each of the four modalities. The intra-rater measurements were taken at a week's interval. Data were analyzed with descriptive and inferential statistics of intraclass correlation coefficient and paired samples T-test, at an alpha level set at P < 0.05.

Results: It showed the palpation technique (r = 0.749-0.967 and 0.658-0.917), digital calipers (r=0.750-0.955 and 0.685-0.904), and diastometer (r=0.762-0.958 and 0.471-0.902) demonstrated good inter- and intra-rater reliability. The concurrent validity of the palpation technique, digital calipers, and diastometer against the USI was poor at all three reference points.

Conclusion: Palpation technique, digital calipers, and diastometer are reliable tools but not valid substitutes to ultrasound imaging for the clinical measurement of diastasis rectus abdominis.

Abstract Image

Abstract Image

Abstract Image

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
腹直分离的评估:四种测量仪器的临床特性。
目的:本研究的目的是确定触诊技术、数字卡尺和舒张仪的评分者内和评分者间的可靠性,以及它们对超声成像的同时有效性。方法:从尼日利亚埃努古的一家产后诊所招募的90名同意分娩的女性(20-45岁)参加了这项观察性研究。两名理疗师和一名声谱师分别使用四种模式中的每一种测量了他们在脐上方和下方4.5厘米处的直肌间距离。评分者内部测量每隔一周进行一次。用组内相关系数的描述性和推断统计学以及配对样本T检验对数据进行分析,α水平设置为P<0.05。结果:触诊技术(r=0.749-0.967和0.658-0.917)、数字卡尺(r=0.750-0.955和0.685-0.904)和舒张计(r=0.762-0.958和0.471-0.902)显示出良好的评分者间和评分者内可靠性。触诊技术、数字卡尺和舒张仪对USI的同时有效性在所有三个参考点都很差。结论:在腹直肌分离的临床测量中,触诊技术、数字卡尺和舒张仪是可靠的工具,但不是超声成像的有效替代品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Health Sciences-IJHS
International Journal of Health Sciences-IJHS MEDICINE, GENERAL & INTERNAL-
自引率
15.00%
发文量
49
审稿时长
8 weeks
期刊最新文献
Biting into accuracy: Evaluating food frequency questionnaires for denture wearers: A systematic review. Challenges of allergic diseases in the Qassim Region of Saudi Arabia: A call for comprehensive prevention and control strategies. Design and synthesis of a novel isoleucine-derived Schiff base ligand: Structural characterization, molecular docking, and in vitro biological activity evaluation. MicroRNA-183-5p negatively regulates interleukin-8 expression in cervical cancer cells. Vitamin D deficiency in pediatric sickle cell disease patients without crisis - A cry to investigate it on priority.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1