{"title":"Outcomes of early cannulation arteriovenous graft versus PTFE arteriovenous graft in hemodialysis patients: A meta-analysis and systematic review.","authors":"Zhuotao Xiao, Joris I Rotmans, Krzysztof Letachowicz, Marco Franchin, Mario D'Oria","doi":"10.1177/11297298231205325","DOIUrl":null,"url":null,"abstract":"<p><p>Arteriovenous graft (AVG) is an alternative for hemodialysis (HD) patients with end-stage renal disease when their permanent vascular accesses fail. Since the last decades, the most widely used materials in these patients have been polytetrafluoroethylene (PTFE)-AVGs. Recently, several studies have reported that early cannulation (EC)-AVG can be an alternative to PTFE-AVG. This systematic review and meta-analysis aimed to compare the outcomes of EC-AVG and PTFE-AVG in HD patients. We searched the Ovid Embase, Ovid MEDLINE, and Cochrane Central Register of Controlled Trials for the relevant studies published from 01.01.2000 to 19.12.2022 by keywords and free words. All randomized controlled trials (RCTs) and observational cohort studies comparing EC-AVG with PTFE-AVG were included. Ten studies were included in analysis: one RCT, six retrospective cohort studies, and three prospective cohort studies. The results showed shorter cannulation intervals (four studies, 1116 participants: mean difference -23.62 days, 95% CI [-32.03, -15.21], <i>p</i> < 0.05) and less central venous catheter (CVC) usage (four studies, 733 participants: OR 0.20, 95% CI [0.04, 0.92], <i>p</i> < 0.05) for EC-AVG compared with PTFE-AVG, while comparable outcomes of primary patency (eight studies, 1712 participants: HR 0.89, 95% CI [0.70, 1.12]), primary assisted patency (five studies, 1355 participants: HR 1.13, 95% CI [0.70, 1.84]), secondary patency (nine studies, 1920 participants: HR 0.93, 95% CI [0.66, 1.31]), and infection risk (four studies, 640 participants: HR 1.12, 95% CI [0.48, 2.58]). When compared to PTFE-AVG in HD patients, EC-AVG seems to exhibit shorter cannulation intervals, less CVC usage, and comparable outcomes of graft patency, and infection risk.</p>","PeriodicalId":56113,"journal":{"name":"Journal of Vascular Access","volume":" ","pages":"1749-1756"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vascular Access","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11297298231205325","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
Abstract
Arteriovenous graft (AVG) is an alternative for hemodialysis (HD) patients with end-stage renal disease when their permanent vascular accesses fail. Since the last decades, the most widely used materials in these patients have been polytetrafluoroethylene (PTFE)-AVGs. Recently, several studies have reported that early cannulation (EC)-AVG can be an alternative to PTFE-AVG. This systematic review and meta-analysis aimed to compare the outcomes of EC-AVG and PTFE-AVG in HD patients. We searched the Ovid Embase, Ovid MEDLINE, and Cochrane Central Register of Controlled Trials for the relevant studies published from 01.01.2000 to 19.12.2022 by keywords and free words. All randomized controlled trials (RCTs) and observational cohort studies comparing EC-AVG with PTFE-AVG were included. Ten studies were included in analysis: one RCT, six retrospective cohort studies, and three prospective cohort studies. The results showed shorter cannulation intervals (four studies, 1116 participants: mean difference -23.62 days, 95% CI [-32.03, -15.21], p < 0.05) and less central venous catheter (CVC) usage (four studies, 733 participants: OR 0.20, 95% CI [0.04, 0.92], p < 0.05) for EC-AVG compared with PTFE-AVG, while comparable outcomes of primary patency (eight studies, 1712 participants: HR 0.89, 95% CI [0.70, 1.12]), primary assisted patency (five studies, 1355 participants: HR 1.13, 95% CI [0.70, 1.84]), secondary patency (nine studies, 1920 participants: HR 0.93, 95% CI [0.66, 1.31]), and infection risk (four studies, 640 participants: HR 1.12, 95% CI [0.48, 2.58]). When compared to PTFE-AVG in HD patients, EC-AVG seems to exhibit shorter cannulation intervals, less CVC usage, and comparable outcomes of graft patency, and infection risk.
当终末期肾病的血液透析(HD)患者的永久性血管通路失败时,动静脉移植物(AVG)是一种替代方案。自过去几十年以来,在这些患者中使用最广泛的材料是聚四氟乙烯(PTFE)-AVG。最近,一些研究报道了早期插管(EC)-AVG可以替代PTFE-AVG。本系统综述和荟萃分析旨在比较EC-AVG和PTFE-AVG在HD患者中的疗效。我们通过关键词和自由词搜索了Ovid Embase、Ovid MEDLINE和Cochrane对照试验中央注册中心,以查找2000年1月1日至2022年12月19日发表的相关研究。包括所有比较EC-AVG和PTFE-AVG的随机对照试验(RCT)和观察性队列研究。分析中包括10项研究:1项随机对照试验,6项回顾性队列研究和3项前瞻性队列研究。结果显示插管间隔更短(四项研究,1116名参与者:平均差异-23.62 天,95%置信区间[32.03,-15.21],p p
期刊介绍:
The Journal of Vascular Access (JVA) is issued six times per year; it considers the publication of original manuscripts dealing with clinical and laboratory investigations in the fast growing field of vascular access. In addition reviews, case reports and clinical trials are welcome, as well as papers dedicated to more practical aspects covering new devices and techniques.
All contributions, coming from all over the world, undergo the peer-review process.
The Journal of Vascular Access is divided into independent sections, each led by Editors of the highest scientific level:
• Dialysis
• Oncology
• Interventional radiology
• Nutrition
• Nursing
• Intensive care
Correspondence related to published papers is also welcome.