Outcomes of early cannulation arteriovenous graft versus PTFE arteriovenous graft in hemodialysis patients: A meta-analysis and systematic review.

IF 1.6 3区 医学 Q3 PERIPHERAL VASCULAR DISEASE Journal of Vascular Access Pub Date : 2024-11-01 Epub Date: 2023-11-07 DOI:10.1177/11297298231205325
Zhuotao Xiao, Joris I Rotmans, Krzysztof Letachowicz, Marco Franchin, Mario D'Oria
{"title":"Outcomes of early cannulation arteriovenous graft versus PTFE arteriovenous graft in hemodialysis patients: A meta-analysis and systematic review.","authors":"Zhuotao Xiao, Joris I Rotmans, Krzysztof Letachowicz, Marco Franchin, Mario D'Oria","doi":"10.1177/11297298231205325","DOIUrl":null,"url":null,"abstract":"<p><p>Arteriovenous graft (AVG) is an alternative for hemodialysis (HD) patients with end-stage renal disease when their permanent vascular accesses fail. Since the last decades, the most widely used materials in these patients have been polytetrafluoroethylene (PTFE)-AVGs. Recently, several studies have reported that early cannulation (EC)-AVG can be an alternative to PTFE-AVG. This systematic review and meta-analysis aimed to compare the outcomes of EC-AVG and PTFE-AVG in HD patients. We searched the Ovid Embase, Ovid MEDLINE, and Cochrane Central Register of Controlled Trials for the relevant studies published from 01.01.2000 to 19.12.2022 by keywords and free words. All randomized controlled trials (RCTs) and observational cohort studies comparing EC-AVG with PTFE-AVG were included. Ten studies were included in analysis: one RCT, six retrospective cohort studies, and three prospective cohort studies. The results showed shorter cannulation intervals (four studies, 1116 participants: mean difference -23.62 days, 95% CI [-32.03, -15.21], <i>p</i> < 0.05) and less central venous catheter (CVC) usage (four studies, 733 participants: OR 0.20, 95% CI [0.04, 0.92], <i>p</i> < 0.05) for EC-AVG compared with PTFE-AVG, while comparable outcomes of primary patency (eight studies, 1712 participants: HR 0.89, 95% CI [0.70, 1.12]), primary assisted patency (five studies, 1355 participants: HR 1.13, 95% CI [0.70, 1.84]), secondary patency (nine studies, 1920 participants: HR 0.93, 95% CI [0.66, 1.31]), and infection risk (four studies, 640 participants: HR 1.12, 95% CI [0.48, 2.58]). When compared to PTFE-AVG in HD patients, EC-AVG seems to exhibit shorter cannulation intervals, less CVC usage, and comparable outcomes of graft patency, and infection risk.</p>","PeriodicalId":56113,"journal":{"name":"Journal of Vascular Access","volume":" ","pages":"1749-1756"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vascular Access","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11297298231205325","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Arteriovenous graft (AVG) is an alternative for hemodialysis (HD) patients with end-stage renal disease when their permanent vascular accesses fail. Since the last decades, the most widely used materials in these patients have been polytetrafluoroethylene (PTFE)-AVGs. Recently, several studies have reported that early cannulation (EC)-AVG can be an alternative to PTFE-AVG. This systematic review and meta-analysis aimed to compare the outcomes of EC-AVG and PTFE-AVG in HD patients. We searched the Ovid Embase, Ovid MEDLINE, and Cochrane Central Register of Controlled Trials for the relevant studies published from 01.01.2000 to 19.12.2022 by keywords and free words. All randomized controlled trials (RCTs) and observational cohort studies comparing EC-AVG with PTFE-AVG were included. Ten studies were included in analysis: one RCT, six retrospective cohort studies, and three prospective cohort studies. The results showed shorter cannulation intervals (four studies, 1116 participants: mean difference -23.62 days, 95% CI [-32.03, -15.21], p < 0.05) and less central venous catheter (CVC) usage (four studies, 733 participants: OR 0.20, 95% CI [0.04, 0.92], p < 0.05) for EC-AVG compared with PTFE-AVG, while comparable outcomes of primary patency (eight studies, 1712 participants: HR 0.89, 95% CI [0.70, 1.12]), primary assisted patency (five studies, 1355 participants: HR 1.13, 95% CI [0.70, 1.84]), secondary patency (nine studies, 1920 participants: HR 0.93, 95% CI [0.66, 1.31]), and infection risk (four studies, 640 participants: HR 1.12, 95% CI [0.48, 2.58]). When compared to PTFE-AVG in HD patients, EC-AVG seems to exhibit shorter cannulation intervals, less CVC usage, and comparable outcomes of graft patency, and infection risk.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
血液透析患者早期套管动静脉移植物与聚四氟乙烯动静脉移动物的疗效:荟萃分析和系统综述。
当终末期肾病的血液透析(HD)患者的永久性血管通路失败时,动静脉移植物(AVG)是一种替代方案。自过去几十年以来,在这些患者中使用最广泛的材料是聚四氟乙烯(PTFE)-AVG。最近,一些研究报道了早期插管(EC)-AVG可以替代PTFE-AVG。本系统综述和荟萃分析旨在比较EC-AVG和PTFE-AVG在HD患者中的疗效。我们通过关键词和自由词搜索了Ovid Embase、Ovid MEDLINE和Cochrane对照试验中央注册中心,以查找2000年1月1日至2022年12月19日发表的相关研究。包括所有比较EC-AVG和PTFE-AVG的随机对照试验(RCT)和观察性队列研究。分析中包括10项研究:1项随机对照试验,6项回顾性队列研究和3项前瞻性队列研究。结果显示插管间隔更短(四项研究,1116名参与者:平均差异-23.62 天,95%置信区间[32.03,-15.21],p p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Vascular Access
Journal of Vascular Access 医学-外周血管病
CiteScore
3.40
自引率
31.60%
发文量
181
审稿时长
6-12 weeks
期刊介绍: The Journal of Vascular Access (JVA) is issued six times per year; it considers the publication of original manuscripts dealing with clinical and laboratory investigations in the fast growing field of vascular access. In addition reviews, case reports and clinical trials are welcome, as well as papers dedicated to more practical aspects covering new devices and techniques. All contributions, coming from all over the world, undergo the peer-review process. The Journal of Vascular Access is divided into independent sections, each led by Editors of the highest scientific level: • Dialysis • Oncology • Interventional radiology • Nutrition • Nursing • Intensive care Correspondence related to published papers is also welcome.
期刊最新文献
Retraction: Novel electrospun polyurethane grafts for vascular access in rats. Feasibility and Safety of bedside placement of tunneled dialysis catheters: A systematic review and meta-analysis of prevalence. Retained foreign body in radial artery: Endovascular retrieval and salvage of a hemodialysis arteriovenous fistula. Role of renal vascular coordinator on access flow dysfunction: A quality improvement initiative on improving patency rate. Ultrasound and fluoroscopy co-guided removal of extravascular stripped central line guidewire fragments.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1