Usefulness of new acoustic respiratory sound monitoring with artificial intelligence for upper airway assessment in obese patients during monitored anesthesia care.

IF 0.7 Q4 MEDICINE, RESEARCH & EXPERIMENTAL JOURNAL OF MEDICAL INVESTIGATION Pub Date : 2023-01-01 DOI:10.2152/jmi.70.430
Yoshitaka Shimizu, Noboru Saeki, Shinichiro Ohshimo, Mitsuru Doi, Kana Oue, Mitsuhiro Yoshida, Tamayo Takahashi, Aya Oda, Takuma Sadamori, Yasuo M Tsutsumi, Nobuaki Shime
{"title":"Usefulness of new acoustic respiratory sound monitoring with artificial intelligence for upper airway assessment in obese patients during monitored anesthesia care.","authors":"Yoshitaka Shimizu, Noboru Saeki, Shinichiro Ohshimo, Mitsuru Doi, Kana Oue, Mitsuhiro Yoshida, Tamayo Takahashi, Aya Oda, Takuma Sadamori, Yasuo M Tsutsumi, Nobuaki Shime","doi":"10.2152/jmi.70.430","DOIUrl":null,"url":null,"abstract":"<p><p>Monitored anesthesia care (MAC) often causes airway complications, particularly posing an elevated risk of aspiration and airway obstruction in obese patients. This study aimed to quantify the levels of aspiration and airway obstruction using an artificial intelligence (AI)-based acoustic analysis algorithm, assessing its utility in identifying airway complications in obese patients. To verify the correlation between the stridor quantitative value (STQV) calculated by acoustic analysis and body weight, and to further evaluate fluid retention and airway obstruction, STQV calculated exhaled breath sounds collected at the neck region, was compared before and after injection of 3 ml of water in the oral cavity and at the start and end of the MAC procedures. STQV measured immediately following the initiation of MAC exhibited a weak correlation with body mass index. Furhtermore, STQV values before and after water injection increased predominantly after injection, further increased at the end of MAC. AI-based analysis of cervical respiratory sounds can enhance the safety of airway management during MAC by quantifying airway obstruction and fluid retention in obese patients. J. Med. Invest. 70 : 430-435, August, 2023.</p>","PeriodicalId":46910,"journal":{"name":"JOURNAL OF MEDICAL INVESTIGATION","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JOURNAL OF MEDICAL INVESTIGATION","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2152/jmi.70.430","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Monitored anesthesia care (MAC) often causes airway complications, particularly posing an elevated risk of aspiration and airway obstruction in obese patients. This study aimed to quantify the levels of aspiration and airway obstruction using an artificial intelligence (AI)-based acoustic analysis algorithm, assessing its utility in identifying airway complications in obese patients. To verify the correlation between the stridor quantitative value (STQV) calculated by acoustic analysis and body weight, and to further evaluate fluid retention and airway obstruction, STQV calculated exhaled breath sounds collected at the neck region, was compared before and after injection of 3 ml of water in the oral cavity and at the start and end of the MAC procedures. STQV measured immediately following the initiation of MAC exhibited a weak correlation with body mass index. Furhtermore, STQV values before and after water injection increased predominantly after injection, further increased at the end of MAC. AI-based analysis of cervical respiratory sounds can enhance the safety of airway management during MAC by quantifying airway obstruction and fluid retention in obese patients. J. Med. Invest. 70 : 430-435, August, 2023.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人工智能新型声学呼吸声监测在监测麻醉护理期间对肥胖患者上呼吸道评估的有用性。
监控麻醉护理(MAC)通常会导致气道并发症,尤其是肥胖患者吸入和气道阻塞的风险增加。本研究旨在使用基于人工智能(AI)的声学分析算法量化抽吸和气道阻塞的水平,评估其在识别肥胖患者气道并发症方面的效用。为了验证通过声学分析计算的喘鸣定量值(STQV)与体重之间的相关性,并进一步评估液体滞留和气道阻塞,在口腔注射3ml水之前和之后以及MAC程序开始和结束时,比较STQV计算的在颈部收集的呼出气声音。MAC开始后立即测量的STQV显示出与体重指数的弱相关性。此外,注水前后STQV值主要在注水后增加,在MAC结束时进一步增加。基于AI的颈部呼吸音分析可以通过量化肥胖患者的气道阻塞和液体滞留来提高MAC期间气道管理的安全性。J.Med.Invest。70:430-4352023年8月。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
JOURNAL OF MEDICAL INVESTIGATION
JOURNAL OF MEDICAL INVESTIGATION MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.20
自引率
0.00%
发文量
55
期刊最新文献
Changes in intestinal microbiota and biochemical parameters in patients with inflammatory bowel disease and irritable bowel syndrome induced by the prolonged addition of soluble fibers to usual drug therapy. Characterization of Outer Membrane Vesicles Produced by Vibrio vulnificus. Clarification of Psychiatric Nurses' Intentions and Analysis Contents in Observing Schizophrenia Patient. Current pharmacotherapies for advanced lung cancer with pre-existing interstitial lung disease : A literature review and future perspectives. Feasibility of laparoscopic and endoscopic cooperative surgery for gastric gastrointestinal stromal tumor with tumor diameter of >5 cm.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1