The impact of body compositions on contrast medium enhancement in chest CT: a randomised controlled trial.

BJR open Pub Date : 2023-10-18 eCollection Date: 2023-01-01 DOI:10.1259/bjro.20230054
Mette Karen Henning, Trond Mogens Aaløkken, Anne Catrine Martinsen, Safora Johansen
{"title":"The impact of body compositions on contrast medium enhancement in chest CT: a randomised controlled trial.","authors":"Mette Karen Henning, Trond Mogens Aaløkken, Anne Catrine Martinsen, Safora Johansen","doi":"10.1259/bjro.20230054","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare a fixed-volume contrast medium (CM) protocol with a combined total body weight (TBW) and body composition-tailored protocol in chest CT.</p><p><strong>Methods and materials: </strong>Patients referred for routine contrast enhanced chest CT were prospectively categorised as normal, muscular or overweight. Patients were accordingly randomised into two groups; Group 1 received a fixed CM protocol. Group 2 received CM volume according to a body composition-tailored protocol. Objective image quality comparisons between protocols and body compositions were performed. Differences between groups and correlation were analysed using <i>t</i>-test and Pearson's <i>r</i>.</p><p><strong>Results: </strong>A total of 179 patients were included: 87 in Group 1 (mean age, 51 ± 17 years); and 92 in Group 2 (mean age, 52 ± 17 years). Compared to Group 2, Group 1 showed lower vascular attenuation in muscular (mean 346 Hounsfield unit (HU) <i>vs</i> 396 HU; <i>p</i> = 0.004) and overweight categories (mean 342 HU <i>vs</i> 367 HU; <i>p</i> = 0.12), while normal category patients showed increased attenuation (385 <i>vs</i> 367; <i>p</i> = 0.61). In Group 1, strongest correlation was found between attenuation and TBW in muscular (<i>r</i> = -.49, <i>p</i> = 0.009) and waist circumference in overweight patients (<i>r</i> = -.50, <i>p</i> = 0.005). In Group 2, no significant correlations were found for the same body size parameters. In Group 1, 13% of the overweight patients was below 250 HU (<i>p</i> = 0.053).</p><p><strong>Conclusion: </strong>A combined TBW and body composition-tailored CM protocol in chest CT resulted in more homogenous enhancement and fewer outliers compared to a fixed-volume protocol.</p><p><strong>Advances in knowledge: </strong>This is, to our knowledge, the first study to investigate the impact of various body compositions on contrast medium enhancement in chest CT.</p>","PeriodicalId":72419,"journal":{"name":"BJR open","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10630975/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BJR open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1259/bjro.20230054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To compare a fixed-volume contrast medium (CM) protocol with a combined total body weight (TBW) and body composition-tailored protocol in chest CT.

Methods and materials: Patients referred for routine contrast enhanced chest CT were prospectively categorised as normal, muscular or overweight. Patients were accordingly randomised into two groups; Group 1 received a fixed CM protocol. Group 2 received CM volume according to a body composition-tailored protocol. Objective image quality comparisons between protocols and body compositions were performed. Differences between groups and correlation were analysed using t-test and Pearson's r.

Results: A total of 179 patients were included: 87 in Group 1 (mean age, 51 ± 17 years); and 92 in Group 2 (mean age, 52 ± 17 years). Compared to Group 2, Group 1 showed lower vascular attenuation in muscular (mean 346 Hounsfield unit (HU) vs 396 HU; p = 0.004) and overweight categories (mean 342 HU vs 367 HU; p = 0.12), while normal category patients showed increased attenuation (385 vs 367; p = 0.61). In Group 1, strongest correlation was found between attenuation and TBW in muscular (r = -.49, p = 0.009) and waist circumference in overweight patients (r = -.50, p = 0.005). In Group 2, no significant correlations were found for the same body size parameters. In Group 1, 13% of the overweight patients was below 250 HU (p = 0.053).

Conclusion: A combined TBW and body composition-tailored CM protocol in chest CT resulted in more homogenous enhancement and fewer outliers compared to a fixed-volume protocol.

Advances in knowledge: This is, to our knowledge, the first study to investigate the impact of various body compositions on contrast medium enhancement in chest CT.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
身体成分对胸部CT造影剂增强的影响:一项随机对照试验。
目的:比较胸部CT中固定体积造影剂(CM)方案与综合总体重(TBW)和身体成分定制方案。方法和材料:常规胸部CT增强扫描的患者前瞻性地分为正常、肌肉发达或超重。患者被随机分为两组;第1组收到一个固定的CM协议。第2组根据身体成分定制方案接受CM体积。对方案和身体成分之间的图像质量进行了客观比较。使用t检验和Pearson’s r分析各组之间的差异和相关性。结果:共有179名患者被纳入:第1组87名(平均年龄51±17岁);第2组92例(平均年龄52±17岁)。与第2组相比,第1组的肌肉血管衰减较低(平均346 Hounsfield单位(HU)vs 396 HU;p=0.004)和超重类别(平均342 HU vs 367 HU;p=0.012),而正常类别患者的衰减增加(385 vs 367;p=0.061)。在第1组中,肌肉衰减与TBW(r=-0.49,p=0.009)和超重患者的腰围(r=-0.50,p=0.005)之间的相关性最强。在第2组中,对于相同的体型参数,没有发现显著的相关性。在第1组中,13%的超重患者低于250HU(p=0.053)。结论:与固定体积方案相比,TBW和身体成分定制的CM方案在胸部CT中产生了更均匀的增强和更少的异常值。知识进步:据我们所知,这是第一项研究各种身体成分对胸部CT造影剂增强的影响的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
18 weeks
期刊最新文献
Three-dimensional dose prediction based on deep convolutional neural networks for brain cancer in CyberKnife: accurate beam modelling of homogeneous tissue. Advancing radiology practice and research: harnessing the potential of large language models amidst imperfections. Improvement in paediatric CT use and justification: a single-centre experience. Deuterium MR spectroscopy: potential applications in oncology research. Unlocking the potential of photon counting detector CT for paediatric imaging: a pictorial essay.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1