Konstantin Doberer , Martin Schiemann , Robert Strassl , Frederik Haupenthal , Florentina Dermuth , Irene Görzer , Farsad Eskandary , Roman Reindl-Schwaighofer , Željko Kikić , Elisabeth Puchhammer-Stöckl , Georg A. Böhmig , Gregor Bond
{"title":"Torque teno virus for risk stratification of graft rejection and infection in kidney transplant recipients—A prospective observational trial","authors":"Konstantin Doberer , Martin Schiemann , Robert Strassl , Frederik Haupenthal , Florentina Dermuth , Irene Görzer , Farsad Eskandary , Roman Reindl-Schwaighofer , Željko Kikić , Elisabeth Puchhammer-Stöckl , Georg A. Böhmig , Gregor Bond","doi":"10.1111/ajt.15810","DOIUrl":null,"url":null,"abstract":"<div><p>The nonpathogenic and ubiquitous torque teno virus (TTV) is associated with immunosuppression in solid organ transplant recipients. Studies in kidney transplant patients proposed TTV quantification for risk stratification of graft rejection and infection. In this prospective trial (DRKS00012335) 386 consecutive kidney transplant recipients were subjected to longitudinal per-protocol monitoring of plasma TTV load by polymerase chain reaction for 12 months posttransplant. TTV load peaked at the end of month 3 posttransplant and reached steady state thereafter. TTV load after the end of month 3 was analyzed in the context of subsequent rejection diagnosed by indication biopsy and infection within the first year posttransplant, respectively. Each log increase in TTV load decreased the odds for rejection by 22% (odds ratio [OR] 0.78, 95% confidence interval [CI] 0.62-0.97; <em>P</em> = .027) and increased the odds for infection by 11% (OR 1.11, 95% CI 1.06-1.15; <em>P</em> < .001). TTV was quantified at a median of 14 days before rejection was diagnosed and 27 days before onset of infection, respectively. We defined a TTV load between 1 × 10<sup>6</sup> and 1 × 10<sup>8</sup> copies/mL as optimal range to minimize the risk for rejection and infection. These data support the initiation of an interventional trial assessing the efficacy of TTV-guided immunosuppression to reduce infection and graft rejection in kidney transplant recipients.</p></div>","PeriodicalId":123,"journal":{"name":"American Journal of Transplantation","volume":"20 8","pages":"Pages 2081-2090"},"PeriodicalIF":8.9000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/ajt.15810","citationCount":"52","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Transplantation","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1600613522225131","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 52
Abstract
The nonpathogenic and ubiquitous torque teno virus (TTV) is associated with immunosuppression in solid organ transplant recipients. Studies in kidney transplant patients proposed TTV quantification for risk stratification of graft rejection and infection. In this prospective trial (DRKS00012335) 386 consecutive kidney transplant recipients were subjected to longitudinal per-protocol monitoring of plasma TTV load by polymerase chain reaction for 12 months posttransplant. TTV load peaked at the end of month 3 posttransplant and reached steady state thereafter. TTV load after the end of month 3 was analyzed in the context of subsequent rejection diagnosed by indication biopsy and infection within the first year posttransplant, respectively. Each log increase in TTV load decreased the odds for rejection by 22% (odds ratio [OR] 0.78, 95% confidence interval [CI] 0.62-0.97; P = .027) and increased the odds for infection by 11% (OR 1.11, 95% CI 1.06-1.15; P < .001). TTV was quantified at a median of 14 days before rejection was diagnosed and 27 days before onset of infection, respectively. We defined a TTV load between 1 × 106 and 1 × 108 copies/mL as optimal range to minimize the risk for rejection and infection. These data support the initiation of an interventional trial assessing the efficacy of TTV-guided immunosuppression to reduce infection and graft rejection in kidney transplant recipients.
期刊介绍:
The American Journal of Transplantation is a leading journal in the field of transplantation. It serves as a forum for debate and reassessment, an agent of change, and a major platform for promoting understanding, improving results, and advancing science. Published monthly, it provides an essential resource for researchers and clinicians worldwide.
The journal publishes original articles, case reports, invited reviews, letters to the editor, critical reviews, news features, consensus documents, and guidelines over 12 issues a year. It covers all major subject areas in transplantation, including thoracic (heart, lung), abdominal (kidney, liver, pancreas, islets), tissue and stem cell transplantation, organ and tissue donation and preservation, tissue injury, repair, inflammation, and aging, histocompatibility, drugs and pharmacology, graft survival, and prevention of graft dysfunction and failure. It also explores ethical and social issues in the field.