Characteristics of ZnS(Ag) + 6LiF Scintillator-Based Detector Used as a Neutron Dosimeter

IF 0.4 4区 工程技术 Q4 NUCLEAR SCIENCE & TECHNOLOGY Atomic Energy Pub Date : 2023-09-08 DOI:10.1007/s10512-023-00998-1
S. V. Kolesnikov, A. P. Denisenko, E. V. Ryabeva
{"title":"Characteristics of ZnS(Ag) + 6LiF Scintillator-Based Detector Used as a Neutron Dosimeter","authors":"S. V. Kolesnikov,&nbsp;A. P. Denisenko,&nbsp;E. V. Ryabeva","doi":"10.1007/s10512-023-00998-1","DOIUrl":null,"url":null,"abstract":"<div><div><p>The signal characteristics of a ZnS(Ag) + <sup>6</sup>LiF scintillator-based detector were investigated. The amplitude and width of the pulses from slow neutrons and electrons <sup>90</sup>Sr–<sup>90</sup>Y were measured on a test bench. The parameter Q, the threshold for detecting neutron events, and the probability of error in determining particles were determined. The selected threshold ensures neutron detection against the electron background (γ-rays) with probability 99.95%, the probability of an error in determining an electron (γ-ray) as a neutron is 0.0001%. So, the test bench is a detector of slow neutrons and can be used as a neutron radiation dosimeter. For this, its design was modernized and calibrated. The ambient equivalent dose rate of neutron radiation measured with the aid of the test bench coincides, to within the error, with the readings of the MKS-AT1117M dosimeter, on measuring in the range 5–100 μSv/h, from a source of fast neutrons <sup>238</sup>Pu–Be.&gt;</p></div></div>","PeriodicalId":480,"journal":{"name":"Atomic Energy","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2023-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atomic Energy","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10512-023-00998-1","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The signal characteristics of a ZnS(Ag) + 6LiF scintillator-based detector were investigated. The amplitude and width of the pulses from slow neutrons and electrons 90Sr–90Y were measured on a test bench. The parameter Q, the threshold for detecting neutron events, and the probability of error in determining particles were determined. The selected threshold ensures neutron detection against the electron background (γ-rays) with probability 99.95%, the probability of an error in determining an electron (γ-ray) as a neutron is 0.0001%. So, the test bench is a detector of slow neutrons and can be used as a neutron radiation dosimeter. For this, its design was modernized and calibrated. The ambient equivalent dose rate of neutron radiation measured with the aid of the test bench coincides, to within the error, with the readings of the MKS-AT1117M dosimeter, on measuring in the range 5–100 μSv/h, from a source of fast neutrons 238Pu–Be.>

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用作中子剂量计的ZnS(Ag) + 6LiF闪烁体探测器的特性
研究了ZnS(Ag) + 6LiF闪烁体探测器的信号特性。在实验台上测量了慢中子和电子90Sr-90Y的脉冲振幅和宽度。确定了参数Q、探测中子事件的阈值和确定粒子的误差概率。所选阈值确保对电子背景(γ射线)的中子检测概率为99.95%,将电子(γ射线)确定为中子的错误概率为0.0001%。因此,该试验台是一个慢中子探测器,可作为中子辐射剂量计使用。为此,它的设计是现代化和校准的。在快中子源238Pu-Be的5 ~ 100 μSv/h范围内,利用该试验台测得的中子辐射环境当量剂量率与MKS-AT1117M剂量计的测量值一致,且在误差范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Atomic Energy
Atomic Energy 工程技术-核科学技术
CiteScore
1.00
自引率
20.00%
发文量
100
审稿时长
4-8 weeks
期刊介绍: Atomic Energy publishes papers and review articles dealing with the latest developments in the peaceful uses of atomic energy. Topics include nuclear chemistry and physics, plasma physics, accelerator characteristics, reactor economics and engineering, applications of isotopes, and radiation monitoring and safety.
期刊最新文献
Prospects for fusion neutron sources in the Russian nuclear power industry Use of a refueling machine mast sipping system to detect leaking FAs during operational fuel cladding failure detection Approaches to slowing down the kinetics of a fast reactor as a means of enhancing its self-protection properties Study into the possibility of using two groups of accelerated preventive protection for VVER-1200 reactors Accounting for the reference data correlation when determining the calculation error using the maximum likelihood method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1