Recovery of heat from animal houses by using heat pumps

Søren Pedersen
{"title":"Recovery of heat from animal houses by using heat pumps","authors":"Søren Pedersen","doi":"10.1016/0167-5826(86)90011-2","DOIUrl":null,"url":null,"abstract":"<div><p>Recovery of heat from animal houses takes place in 1% of all Danish farms. At the beginning, which means in the Seventies, air/water evaporators of copper-aluminium were mostly used. Because of problems with corrosion, most of the heat pumps today are water/water types with external heat exchangers of artificial material such as PVC and PEL.</p><p>Field testing is complete with 17 heat pumps for animal houses, and experiments with an additional 20 units have been initiated. The results show that the mean effect factor is 2.3, taking into account the total energy consumption for compressor, ventilator, circulation pumps etc. The mean effect factor concerning the compressor alone is 3.0.</p><p>In the near future an effect factor of 2.5–3.0 seems to be possible.</p></div>","PeriodicalId":100470,"journal":{"name":"Energy in Agriculture","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1986-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5826(86)90011-2","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy in Agriculture","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0167582686900112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Recovery of heat from animal houses takes place in 1% of all Danish farms. At the beginning, which means in the Seventies, air/water evaporators of copper-aluminium were mostly used. Because of problems with corrosion, most of the heat pumps today are water/water types with external heat exchangers of artificial material such as PVC and PEL.

Field testing is complete with 17 heat pumps for animal houses, and experiments with an additional 20 units have been initiated. The results show that the mean effect factor is 2.3, taking into account the total energy consumption for compressor, ventilator, circulation pumps etc. The mean effect factor concerning the compressor alone is 3.0.

In the near future an effect factor of 2.5–3.0 seems to be possible.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用热泵回收动物饲养场的热量
丹麦1%的农场从动物饲养场回收热量。一开始,也就是说在70年代,主要使用铜铝的空气/水蒸发器。由于腐蚀问题,目前大多数热泵都是带PVC和PEL等人造材料外部换热器的水/水类型。动物饲养场的17台热泵的现场测试已经完成,另外20台热泵的实验已经开始。结果表明,考虑到压缩机、通风机、循环泵等的总能耗,平均影响因子为2.3。仅压缩机的平均影响因子是3.0。在不久的将来,2.5–3.0的影响因子似乎是可能的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Publisher's note Author index Economic realities of utilizing renewable energy in agriculture Biomass: Recent economic studies Anaerobic digestion of farm waste
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1