{"title":"DESIGN OF A SIMPLE MUFFLE FURNACE FOR TEMPERATURE OPTIMIZATION IN ASH CONTENT ANALYSIS","authors":"F. R. Abadi","doi":"10.18860/NEU.V10I2.4559","DOIUrl":null,"url":null,"abstract":"<p class=\"abstrak\">Analysis of the ash content in biomass conducted through the incineration process in the muffle furnace at a given temperature of 575<span style=\"text-decoration: underline;\">+</span>25<sup>o</sup>C. The result depends on the accuracy level on the temperature sensor in the muffle furnace. It was attempted to achieve the optimum temperature and to detect the muffle furnace temperature by installing the thermocouple sensor type K directly the porcelain sample plate. It yielded that by direct incineration process and gradual process the setup point reached in 60-90 minutes and 150-180 minutes before attaining the steady temperature, respectively. The temperature distributed uniformly for all treatments at <span style=\"text-decoration: underline;\">+</span> 6.61 <sup>o</sup>C. The temperature measurement accuracy was <span style=\"text-decoration: underline;\">+</span> 1.18%, and the overall temperature gradient was <span style=\"text-decoration: underline;\">+</span> 28.69 <sup>o</sup>C. Moreover, there was no difference in the temperature fluctuation among the treatments at the temperature of <span style=\"text-decoration: underline;\">+</span> 20.95 <sup>o</sup>C. The optimum temperature of the chamber was 588 <sup>o</sup>C for analyzing ash content of biomass.</p>","PeriodicalId":17685,"journal":{"name":"Jurnal Neutrino","volume":"1999 9","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Neutrino","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18860/NEU.V10I2.4559","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Analysis of the ash content in biomass conducted through the incineration process in the muffle furnace at a given temperature of 575+25oC. The result depends on the accuracy level on the temperature sensor in the muffle furnace. It was attempted to achieve the optimum temperature and to detect the muffle furnace temperature by installing the thermocouple sensor type K directly the porcelain sample plate. It yielded that by direct incineration process and gradual process the setup point reached in 60-90 minutes and 150-180 minutes before attaining the steady temperature, respectively. The temperature distributed uniformly for all treatments at + 6.61 oC. The temperature measurement accuracy was + 1.18%, and the overall temperature gradient was + 28.69 oC. Moreover, there was no difference in the temperature fluctuation among the treatments at the temperature of + 20.95 oC. The optimum temperature of the chamber was 588 oC for analyzing ash content of biomass.