Comparison of the Acute Hematopoietic Capacities of Erythropoietin and U-74389G Concerning Hematocrit Levels.

C. Tsompos, C. Panoulis, K. Toutouzas, A. Triantafyllou, G. Zografos, A. Papalois
{"title":"Comparison of the Acute Hematopoietic Capacities of Erythropoietin and U-74389G Concerning Hematocrit Levels.","authors":"C. Tsompos, C. Panoulis, K. Toutouzas, A. Triantafyllou, G. Zografos, A. Papalois","doi":"10.2174/1871529X17666170201104158","DOIUrl":null,"url":null,"abstract":"AIM\nThis study compared the hematopoietic capacities of erythropoietin (Epo) and antioxidant drug U-74389G, based on 2 preliminary studies. The provided results on hematocrit levels augmentation were co-evaluated in a hypoxia reoxygenation protocol of an animal model.\n\n\nMATERIALS AND METHODS\nHematocrit levels were evaluated at the 60th reoxygenation min (for groups A, C and E) and at the 120th reoxygenation min (for groups B, D and F) in 60 rats. Groups A and B received no drugs, rats from groups C and D were administered with Epo; whereas rats from groups E and F were administered with U-74389G.\n\n\nRESULTS\nThe first preliminary study of Epo non-significantly increased the hematocrit levels by 0.24%+1.38% (p-value=0.8586). The second preliminary study of U-74389G significantly raised the hematocrit levels by 3.16%+1.33% (p-value=0.0196). These 2 studies were co-evaluated since they came from the same experimental setting. The outcome of the co-evaluation was that U-74389G has approximately 12.66-fold higher hematopoietic potency than Epo (p-value=0.0000).\n\n\nCONCLUSION\nThe anti-oxidant capacities of U-74389G provide satisfactory acute hematopoietic properties; presenting approximately 12.66-fold hematocrit level rise than epo (p-value=0.0000).","PeriodicalId":93925,"journal":{"name":"Cardiovascular & hematological disorders drug targets","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular & hematological disorders drug targets","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1871529X17666170201104158","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

AIM This study compared the hematopoietic capacities of erythropoietin (Epo) and antioxidant drug U-74389G, based on 2 preliminary studies. The provided results on hematocrit levels augmentation were co-evaluated in a hypoxia reoxygenation protocol of an animal model. MATERIALS AND METHODS Hematocrit levels were evaluated at the 60th reoxygenation min (for groups A, C and E) and at the 120th reoxygenation min (for groups B, D and F) in 60 rats. Groups A and B received no drugs, rats from groups C and D were administered with Epo; whereas rats from groups E and F were administered with U-74389G. RESULTS The first preliminary study of Epo non-significantly increased the hematocrit levels by 0.24%+1.38% (p-value=0.8586). The second preliminary study of U-74389G significantly raised the hematocrit levels by 3.16%+1.33% (p-value=0.0196). These 2 studies were co-evaluated since they came from the same experimental setting. The outcome of the co-evaluation was that U-74389G has approximately 12.66-fold higher hematopoietic potency than Epo (p-value=0.0000). CONCLUSION The anti-oxidant capacities of U-74389G provide satisfactory acute hematopoietic properties; presenting approximately 12.66-fold hematocrit level rise than epo (p-value=0.0000).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
促红细胞生成素与U-74389G急性造血能力与红细胞压积水平的比较
目的在2项初步研究的基础上,比较了促红细胞生成素(Epo)与抗氧化药物U-74389G的造血能力。提供的红细胞压积水平增加的结果在动物模型的缺氧再氧化方案中进行了共同评估。材料与方法测定60只大鼠复氧第60 min (A、C、E组)和第120 min (B、D、F组)的红细胞压积水平。A、B组不给药,C、D组给Epo;E、F组大鼠给予U-74389G。结果第一次初步研究Epo非显著提高红细胞压积0.24%+1.38% (p值=0.8586)。第二次初步研究U-74389G显著提高红细胞压积3.16%+1.33% (p值=0.0196)。这两项研究是共同评估的,因为它们来自相同的实验环境。联合评价的结果是U-74389G的造血效能比Epo高约12.66倍(p值=0.0000)。结论U-74389G具有良好的抗氧化能力,具有良好的急性造血功能;红细胞压积比促红细胞生成素升高约12.66倍(p值=0.0000)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Acute Myeloid Leukemia Presenting as Extensive Arterial and Venous Thrombosis: A Case Report. Inter-atrial Septum Stenting in Congenital Heart Disease Patient: A Case Series in Indonesia. Exploring the Role of Secondary Metabolites from Plants and Microbes as Modulators of Macrophage Differentiation. Dengue Fever Related Reactive Thrombocytosis in Young Male: A Case Report and Review Literature. Toll-like Receptors: Therapeutic Potential in Life Threatening Diseases-Cardiac Disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1