Seismic behavior and failure modes of non-ductile three-story reinforced concrete structure: A numerical investigation

IF 2.9 4区 工程技术 Q2 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS Computers and Concrete Pub Date : 2021-05-01 DOI:10.12989/CAC.2021.27.5.457
B. A. Hidayat, Hsuan-Teh Hu, F. Hsiao, A. Han, Lisha Sosa, L. Chan, Y. Haryanto
{"title":"Seismic behavior and failure modes of non-ductile three-story reinforced concrete structure: A numerical investigation","authors":"B. A. Hidayat, Hsuan-Teh Hu, F. Hsiao, A. Han, Lisha Sosa, L. Chan, Y. Haryanto","doi":"10.12989/CAC.2021.27.5.457","DOIUrl":null,"url":null,"abstract":"Reinforced concrete (RC) buildings in Taiwan have suffered failure from strong earthquakes, which was magnified by the non-ductile detailing frames. Inadequate reinforcement as a consequence of the design philosophy prior to the introduction of current standards resulted in severe damage in the column and beam-column joint (BCJ). This study establishes a finite element analysis (FEA) of the non-ductile detailing RC column, BCJ, and three-story building that was previously tested through a tri-axial shaking table test. The results were then validated to laboratory specimens having the exact same dimensions and properties. FEA simulation integrates the concrete damage plasticity model and the elastic-perfectly plastic model for steel. The load-displacement responses of the column and BCJ specimens obtained from FEA were in a reasonable agreement with the experimental curves. The resulting initial stiffness and maximum base shear were found to be a close approximation to the experimental results. Also, the findings of a dynamic analysis of the three-story building showed that the time-history data of acceleration and displacement correlated well with the shaking table test results. This indicates the FEA implementation can be effectively used to predict the RC frame performance and failure mode under seismic loads.","PeriodicalId":50625,"journal":{"name":"Computers and Concrete","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2021-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers and Concrete","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.12989/CAC.2021.27.5.457","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 5

Abstract

Reinforced concrete (RC) buildings in Taiwan have suffered failure from strong earthquakes, which was magnified by the non-ductile detailing frames. Inadequate reinforcement as a consequence of the design philosophy prior to the introduction of current standards resulted in severe damage in the column and beam-column joint (BCJ). This study establishes a finite element analysis (FEA) of the non-ductile detailing RC column, BCJ, and three-story building that was previously tested through a tri-axial shaking table test. The results were then validated to laboratory specimens having the exact same dimensions and properties. FEA simulation integrates the concrete damage plasticity model and the elastic-perfectly plastic model for steel. The load-displacement responses of the column and BCJ specimens obtained from FEA were in a reasonable agreement with the experimental curves. The resulting initial stiffness and maximum base shear were found to be a close approximation to the experimental results. Also, the findings of a dynamic analysis of the three-story building showed that the time-history data of acceleration and displacement correlated well with the shaking table test results. This indicates the FEA implementation can be effectively used to predict the RC frame performance and failure mode under seismic loads.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
非延性三层钢筋混凝土结构抗震性能及破坏模式的数值研究
台湾的钢筋混凝土(RC)建筑在强烈地震中遭受破坏,而非延性的细节框架则加剧了这种破坏。在引入现行标准之前的设计理念导致加固不足,导致柱和梁柱节点(BCJ)严重损坏。本研究建立了非延性混凝土细部柱、BCJ和三层建筑的有限元分析(FEA),之前通过三轴振动台试验进行了测试。然后将结果与具有完全相同尺寸和特性的实验室样品进行验证。有限元模拟将混凝土损伤塑性模型与钢的弹塑性模型相结合。有限元分析得到的柱和BCJ试件的荷载-位移响应与试验曲线吻合较好。所得到的初始刚度和最大基底剪力与实验结果非常接近。另外,对三层建筑的动力分析结果表明,加速度和位移时程数据与振动台试验结果吻合良好。这表明有限元分析可以有效地预测钢筋混凝土框架在地震荷载作用下的性能和破坏模式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Computers and Concrete
Computers and Concrete 工程技术-材料科学:表征与测试
CiteScore
8.60
自引率
7.30%
发文量
0
审稿时长
13.5 months
期刊介绍: Computers and Concrete is An International Journal that focuses on the computer applications in be considered suitable for publication in the journal. The journal covers the topics related to computational mechanics of concrete and modeling of concrete structures including plasticity fracture mechanics creep thermo-mechanics dynamic effects reliability and safety concepts automated design procedures stochastic mechanics performance under extreme conditions.
期刊最新文献
Numerical investigation on RC T-beams strengthened in the negative moment region using NSM FRP rods at various depth of embedment Forced vibration analysis of a micro sandwich plate with an isotropic/orthotropic cores and polymeric nanocomposite face sheets Influence of non-persistent joint sets on the failure behaviour of concrete under uniaxial compression test Nonlinear vibration behavior of hybrid multi-scale cylindrical panels via semi numerical method Improving the seismic performance of reinforced concrete frames using an innovative metallic-shear damper
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1