Q-Switch Nd:YAG Laser-Assisted Decontamination of Implant Surface

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Open Dentistry Journal Pub Date : 2019-10-01 DOI:10.3390/dj7040099
M. Namour, Marwan El Mobadder, D. Magnin, A. Peremans, T. Verspecht, W. Teughels, L. Lamard, S. Nammour, E. Rompen
{"title":"Q-Switch Nd:YAG Laser-Assisted Decontamination of Implant Surface","authors":"M. Namour, Marwan El Mobadder, D. Magnin, A. Peremans, T. Verspecht, W. Teughels, L. Lamard, S. Nammour, E. Rompen","doi":"10.3390/dj7040099","DOIUrl":null,"url":null,"abstract":"Peri-implantitis (PI) is an inflammatory disease of peri-implant tissues, it represents the most frequent complication of dental implants. Evidence revealed that microorganisms play the chief role in causing PI. The purpose of our study is to evaluate the cleaning of contaminated dental implant surfaces by means of the Q-switch Nd:YAG (Neodymium-doped Yttrium Aluminum Garnet) laser and an increase in temperature at lased implant surfaces during the cleaning process. Seventy-eight implants (titanium grade 4) were used (Euroteknika, Sallanches, France). Thirty-six sterile implants and forty-two contaminated implants were collected from failed clinical implants for different reasons, independent from the study. Thirty-six contaminated implants were partially irradiated by Q-switch Nd:YAG laser (1064 nm). Six other contaminated implants were used for temperature rise evaluation. All laser irradiations were calibrated by means of a powermetter in order to evaluate the effective delivered energy. The irradiation conditions delivered per pulse on the target were effectively: energy density per pulse of 0.597 J/cm2, pick powers density of 56 mW/cm2, 270 mW per pulse with a spot diameter of 2.4 mm, and with repetition rate of 10 Hz for pulse duration of 6 ns. Irradiation was performed during a total time of 2 s in a non-contact mode at a distance of 0.5 mm from implant surfaces. The parameters were chosen according to the results of a theoretical modeling calculation of the Nd:YAG laser fluency on implant surface. Evaluation of contaminants removal showed that the cleaning of the irradiated implant surfaces was statistically similar to those of sterile implants (p-value ≤ 0.05). SEM analysis confirmed that our parameters did not alter the lased surfaces. The increase in temperature generated at lased implant surfaces during cleaning was below 1 °C. According to our findings, Q-switch Nd:YAG laser with short pulse duration in nanoseconds is able to significantly clean contaminated implant surfaces. Irradiation parameters used in our study can be considered safe for periodontal tissue.","PeriodicalId":47284,"journal":{"name":"Open Dentistry Journal","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj7040099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 13

Abstract

Peri-implantitis (PI) is an inflammatory disease of peri-implant tissues, it represents the most frequent complication of dental implants. Evidence revealed that microorganisms play the chief role in causing PI. The purpose of our study is to evaluate the cleaning of contaminated dental implant surfaces by means of the Q-switch Nd:YAG (Neodymium-doped Yttrium Aluminum Garnet) laser and an increase in temperature at lased implant surfaces during the cleaning process. Seventy-eight implants (titanium grade 4) were used (Euroteknika, Sallanches, France). Thirty-six sterile implants and forty-two contaminated implants were collected from failed clinical implants for different reasons, independent from the study. Thirty-six contaminated implants were partially irradiated by Q-switch Nd:YAG laser (1064 nm). Six other contaminated implants were used for temperature rise evaluation. All laser irradiations were calibrated by means of a powermetter in order to evaluate the effective delivered energy. The irradiation conditions delivered per pulse on the target were effectively: energy density per pulse of 0.597 J/cm2, pick powers density of 56 mW/cm2, 270 mW per pulse with a spot diameter of 2.4 mm, and with repetition rate of 10 Hz for pulse duration of 6 ns. Irradiation was performed during a total time of 2 s in a non-contact mode at a distance of 0.5 mm from implant surfaces. The parameters were chosen according to the results of a theoretical modeling calculation of the Nd:YAG laser fluency on implant surface. Evaluation of contaminants removal showed that the cleaning of the irradiated implant surfaces was statistically similar to those of sterile implants (p-value ≤ 0.05). SEM analysis confirmed that our parameters did not alter the lased surfaces. The increase in temperature generated at lased implant surfaces during cleaning was below 1 °C. According to our findings, Q-switch Nd:YAG laser with short pulse duration in nanoseconds is able to significantly clean contaminated implant surfaces. Irradiation parameters used in our study can be considered safe for periodontal tissue.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
q开关Nd:YAG激光辅助种植体表面去污
种植体周围炎(PI)是种植体周围组织的炎症性疾病,是种植体最常见的并发症。有证据表明,微生物在引起PI中起主要作用。我们的研究目的是评估使用q开关Nd:YAG(掺钕钇铝石榴石)激光器对受污染种植体表面的清洁效果,以及在清洁过程中激光种植体表面温度的升高。使用了78个种植体(钛级4)(Euroteknika, Sallanches, France)。36个无菌种植体和42个污染种植体来自于不同原因的临床失败种植体,独立于研究。用q开关Nd:YAG激光(1064 nm)局部照射36个污染植体。另外6个受污染的植入物用于温升评估。所有的激光照射都是通过功率计校准的,以便评估有效传递的能量。每脉冲照射目标的有效条件为:每脉冲能量密度0.597 J/cm2,拾取功率密度56 mW/cm2, 270 mW/脉冲,光斑直径2.4 mm,重复频率10 Hz,脉冲持续时间6 ns。在距离种植体表面0.5 mm的距离处,以非接触方式照射,总时间为2 s。根据Nd:YAG激光在植入体表面的流畅度的理论建模计算结果选择参数。污染物去除率评估显示,辐照种植体表面的清洁度与无菌种植体的清洁度在统计学上相似(p值≤0.05)。扫描电镜分析证实,我们的参数没有改变激光表面。在清洗过程中,激光植入物表面产生的温度升高低于1°C。根据我们的研究结果,短脉冲持续时间(纳秒)的q开关Nd:YAG激光器能够显著清洁受污染的植入物表面。在我们的研究中使用的辐照参数可以被认为是安全的牙周组织。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Open Dentistry Journal
Open Dentistry Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.00
自引率
0.00%
发文量
86
期刊最新文献
Calculus as a Risk Factor for Periodontal Disease: Narrative Review on Treatment Indications When the Response to Scaling and Root Planing Is Inadequate. Caries Experience and Treatment Needs in Urban and Rural Environments in School-Age Children from Three Provinces of Ecuador: A Cross-Sectional Study Cannabidiol in Dentistry: A Scoping Review Effectiveness of 38% Silver Diamine Fluoride in Reducing Dentine Hypersensitivity on Exposed Root Surface in Older Chinese Adults: Study Protocol for a Randomised Double-Blind Study Challenges and Opportunities for Dental Education from COVID-19
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1