Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy

Serhat Aras, I. Tanzer, T. Ikizceli
{"title":"Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy","authors":"Serhat Aras, I. Tanzer, T. Ikizceli","doi":"10.18466/CBAYARFBE.654782","DOIUrl":null,"url":null,"abstract":"In this study, the effects of various bolus materials on dose distributions were compared in electron conformal radiotherapy (ECRT). Superflab, Super Stuff pink wax and Paraffin wax bolus materials are used with 15MeV electron energy for dosimetric comparison. Additionally, 10 mm thick Super Stuff pink wax bolus and paraffin wax bolus materials were placed on the right eyelid of a patient. Using electron dose calculation algorithm and ion chamber measurements, dosimetric comparisons were made in the Eclipse treatment planning system (TPS). Both for measured and calculated dose, values were acquired 3 times and averaged for each case. Resulting differences are expressed as percentage differences. Dose differences were obtained in measurements with and without using bolus at several locations of the solid phantom, performed by the Roos Ion chamber. Dosimetric differences of 7-7.5% for Superflab, 10-10.5% for paraffin bolus and 13-14% for Super Stuff pink wax bolus are obtained. Besides, when dosimetric comparisons are made in the treatment planning system for cases with and without bolus; Dose differences were calculated to be 2-2.5% for superflab silicon bolus, 3-3.5% for paraffin wax bolus and 5-6% for Super Stuff pink wax bolus. To increase skin dose in curved anatomical structures in radiotherapy, it is safe to use the paraffin wax bolus material in radiotherapy clinic, as an alternative to Superflab silicon bolus and Super Stuff pink wax bolus materials, due to its low cost and ease of conforming to body surface contours.","PeriodicalId":9652,"journal":{"name":"Celal Bayar Universitesi Fen Bilimleri Dergisi","volume":"246 1","pages":"201-205"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Celal Bayar Universitesi Fen Bilimleri Dergisi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18466/CBAYARFBE.654782","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this study, the effects of various bolus materials on dose distributions were compared in electron conformal radiotherapy (ECRT). Superflab, Super Stuff pink wax and Paraffin wax bolus materials are used with 15MeV electron energy for dosimetric comparison. Additionally, 10 mm thick Super Stuff pink wax bolus and paraffin wax bolus materials were placed on the right eyelid of a patient. Using electron dose calculation algorithm and ion chamber measurements, dosimetric comparisons were made in the Eclipse treatment planning system (TPS). Both for measured and calculated dose, values were acquired 3 times and averaged for each case. Resulting differences are expressed as percentage differences. Dose differences were obtained in measurements with and without using bolus at several locations of the solid phantom, performed by the Roos Ion chamber. Dosimetric differences of 7-7.5% for Superflab, 10-10.5% for paraffin bolus and 13-14% for Super Stuff pink wax bolus are obtained. Besides, when dosimetric comparisons are made in the treatment planning system for cases with and without bolus; Dose differences were calculated to be 2-2.5% for superflab silicon bolus, 3-3.5% for paraffin wax bolus and 5-6% for Super Stuff pink wax bolus. To increase skin dose in curved anatomical structures in radiotherapy, it is safe to use the paraffin wax bolus material in radiotherapy clinic, as an alternative to Superflab silicon bolus and Super Stuff pink wax bolus materials, due to its low cost and ease of conforming to body surface contours.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同丸剂在电子适形放疗中的剂量分布效应比较
本研究比较了电子适形放疗(ECRT)中不同剂量材料对剂量分布的影响。Superflab、Super Stuff粉蜡和石蜡丸材料采用15MeV电子能量进行剂量学比较。另外,将10毫米厚的Super Stuff粉蜡丸和石蜡丸材料放置在患者的右眼睑上。采用电子剂量计算算法和离子室测量法,在Eclipse治疗计划系统(TPS)中进行剂量学比较。测量剂量和计算剂量均取3次平均值。产生的差异以百分比差异表示。通过Roos离子室在固体幻体的几个位置测量使用和不使用丸剂的剂量差异。Superflab的剂量学差异为7-7.5%,石蜡丸为10-10.5%,Super Stuff粉蜡丸为13-14%。此外,在治疗计划系统中对服用和不服用丸剂的病例进行剂量学比较时;计算出superflab硅丸的剂量差异为2-2.5%,石蜡丸为3-3.5%,Super Stuff粉蜡丸为5-6%。为了在放射治疗中增加弯曲解剖结构的皮肤剂量,在放射治疗临床中使用石蜡丸材料是安全的,可以替代Superflab硅丸和Super Stuff粉蜡丸材料,因为其成本低且易于符合体表轮廓。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A study on the solutions of (3+1) conformal time derivative generalized q-deformed Sinh-Gordon equation Use of Pyrolysed Almond and Walnut Shells (PAS and PWS) for the Adsorption of Cationic Dye: Reusing Agro-Waste for Sustainable Development Palladium/1,3-bis(ferrocenylmethy)imidazolinium chloride catalyst for Suzuki cross-coupling reactions Evaluation of Various Flexibility Resources in Power Systems Chemical Composition and Antibacterial Activities of Corylus avellana L. Bioproducts Grown in Giresun-Türkiye
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1