A new passive sampler for regulated workplace ketones.

S. Tsai, S. S. Hee
{"title":"A new passive sampler for regulated workplace ketones.","authors":"S. Tsai, S. S. Hee","doi":"10.1080/15298660008984590","DOIUrl":null,"url":null,"abstract":"A new solid sorbent passive air sampler for ketones has a silicone membrane atop a diffusion cylindrical path length of 1.1 cm and diameter 1.3 cm above a pellet of Tenax TA coated with 10% (w/w) O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride. Vapors of known concentrations approximating their workplace permissible exposure limits of Occupational Safety and Health Administration-regulated ketones at a relative humidity (RH) of 3 +/- 1% were generated by a syringe pump connected to a dynamic air dilution system connected to an exposure chamber that allowed measurement of face velocities, temperatures, exposing vapor concentrations, and RHs. The O-oxime derivative was desorbed with hexane, and an aliquot injected for gas chromatographic analysis on a nonpolar capillary column by mass spectrometric or electron capture detection. The experimental passive sampler sampling rates in milliliters per minute at 25 degrees C were 4.07 +/- 0.49, cyclohexanone; 6.30 +/- 0.59, diethyl ketone; 6.31 +/- 0.31, ethyl n-butyl ketone; 3.78 +/- 0.25, methyl n-amyl ketone; 3.43 +/- 0.19, methyl n-butyl ketone; 6.48 +/- 0.64, methyl ethyl ketone; 4.37 +/- 0.43, methyl isopropyl ketone; and 4.57 +/- 0.17, methyl n-propyl ketone. These preliminary data show that sterically unhindered ketones can be sampled by the passive sampler as well as aldehydes.","PeriodicalId":7449,"journal":{"name":"AIHAJ : a journal for the science of occupational and environmental health and safety","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2000-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AIHAJ : a journal for the science of occupational and environmental health and safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/15298660008984590","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

A new solid sorbent passive air sampler for ketones has a silicone membrane atop a diffusion cylindrical path length of 1.1 cm and diameter 1.3 cm above a pellet of Tenax TA coated with 10% (w/w) O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride. Vapors of known concentrations approximating their workplace permissible exposure limits of Occupational Safety and Health Administration-regulated ketones at a relative humidity (RH) of 3 +/- 1% were generated by a syringe pump connected to a dynamic air dilution system connected to an exposure chamber that allowed measurement of face velocities, temperatures, exposing vapor concentrations, and RHs. The O-oxime derivative was desorbed with hexane, and an aliquot injected for gas chromatographic analysis on a nonpolar capillary column by mass spectrometric or electron capture detection. The experimental passive sampler sampling rates in milliliters per minute at 25 degrees C were 4.07 +/- 0.49, cyclohexanone; 6.30 +/- 0.59, diethyl ketone; 6.31 +/- 0.31, ethyl n-butyl ketone; 3.78 +/- 0.25, methyl n-amyl ketone; 3.43 +/- 0.19, methyl n-butyl ketone; 6.48 +/- 0.64, methyl ethyl ketone; 4.37 +/- 0.43, methyl isopropyl ketone; and 4.57 +/- 0.17, methyl n-propyl ketone. These preliminary data show that sterically unhindered ketones can be sampled by the passive sampler as well as aldehydes.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种新的受管制工作场所酮类被动采样器。
一种新型的固体吸附剂被动空气酮取样器,其扩散柱状路径长度为1.1 cm,直径为1.3 cm,其上覆盖有10% (w/w) O-(2,3,4,5,6-五氟苯基)羟胺的Tenax TA颗粒。在相对湿度(RH)为3 +/- 1%的情况下,由与动态空气稀释系统相连的注射泵产生的已知浓度接近其工作场所允许暴露极限的蒸汽,该系统与暴露室相连,可以测量表面速度、温度、暴露蒸汽浓度和RHs。邻肟衍生物用己烷解吸,并在非极性毛细管柱上通过质谱或电子捕获检测进行气相色谱分析。实验被动进样器在25℃下取样率(毫升/分钟)为4.07±0.49,环己酮;6.30 +/- 0.59,二乙基酮;6.31 +/- 0.31,乙基正丁基酮;3.78 +/- 0.25,甲基n-戊基酮;3.43 +/- 0.19,甲基正丁基酮;6.48 +/- 0.64,甲基乙基酮;4.37 +/- 0.43,甲基异丙基酮;4.57 +/- 0.17,正丙基甲基酮。这些初步数据表明,被动采样器可以对空间无阻碍的酮类和醛类进行采样。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Approaches and considerations for setting occupational exposure limits for sensory irritants: report of recent symposia. Approach to setting occupational exposure limits for sensory irritants in The Netherlands. The origin of a nicotine detection method. Telephone communications with several commercial respirators. Replotting data for chronic beryllium disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1