Determination of Entrance Surface Dose of Digital Radiography for Adults at Public Medical Imaging Centers, Erbil

I. Ibrahim
{"title":"Determination of Entrance Surface Dose of Digital Radiography for Adults at Public Medical Imaging Centers, Erbil","authors":"I. Ibrahim","doi":"10.18502/TBSRJ.V3I2.6671","DOIUrl":null,"url":null,"abstract":"Introduction: Diagnostic X-ray is one of the ionizing radiations, the level of radiation dose received by the patient during medical examination is essential to prevent cancer risks. The aim of this study is to calculate entrance surface dose (ESD) and effective dose (ED) were estimated during chest, and lumber spine for adult patients in three hospitals in Erbil, using NOMEX MULTIMETER and PCXMC software.    \nMaterial and Methods: The study was conducted in three public hospitals, in Erbil on (250) adult patients, whose ages between (18-70) years, based on the results study, ESD and ED were calculated for chest (PA, lateral), and lumbar spine (AP, lateral) examinations. NOMEX MULTIMETER (PTW, Freiburg), used in measurement of tube voltage, dose, dose rate, time product current, and total filtration automatically during examination. ED was calculated by using PCXMC software (version 2.5). \nResults: The results of this work are compared with published international literatures. The mean entrance skin dose for examinations of chest (PA, Lat), and lumber spine (AP, Lat) 1.02, 1.06, 2.61 and 3.92 mGy respectively. ED value was from 0.08, 0.19, 0.32, and 0.33 mSv, for chest (PA, Lat), and lumber spine (AP, Lat), respectively. \nConclusion: The ESD, and ED were calculated in this work were found to be agreement with the published reference values for chest, and lumber spine set by international levels. ALARA principle should be considered by radiographer, to reduce absorbed dose of adults’ patient undergoing imaging radiography.","PeriodicalId":22117,"journal":{"name":"Tabari Biomedical Student Research Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tabari Biomedical Student Research Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/TBSRJ.V3I2.6671","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Diagnostic X-ray is one of the ionizing radiations, the level of radiation dose received by the patient during medical examination is essential to prevent cancer risks. The aim of this study is to calculate entrance surface dose (ESD) and effective dose (ED) were estimated during chest, and lumber spine for adult patients in three hospitals in Erbil, using NOMEX MULTIMETER and PCXMC software.    Material and Methods: The study was conducted in three public hospitals, in Erbil on (250) adult patients, whose ages between (18-70) years, based on the results study, ESD and ED were calculated for chest (PA, lateral), and lumbar spine (AP, lateral) examinations. NOMEX MULTIMETER (PTW, Freiburg), used in measurement of tube voltage, dose, dose rate, time product current, and total filtration automatically during examination. ED was calculated by using PCXMC software (version 2.5). Results: The results of this work are compared with published international literatures. The mean entrance skin dose for examinations of chest (PA, Lat), and lumber spine (AP, Lat) 1.02, 1.06, 2.61 and 3.92 mGy respectively. ED value was from 0.08, 0.19, 0.32, and 0.33 mSv, for chest (PA, Lat), and lumber spine (AP, Lat), respectively. Conclusion: The ESD, and ED were calculated in this work were found to be agreement with the published reference values for chest, and lumber spine set by international levels. ALARA principle should be considered by radiographer, to reduce absorbed dose of adults’ patient undergoing imaging radiography.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
埃尔比勒公共医学成像中心成人数字放射照相入口表面剂量的测定
诊断x射线是电离辐射的一种,病人在体检时接受的辐射剂量水平对预防癌症风险至关重要。本研究的目的是利用NOMEX万用表和PCXMC软件计算埃尔比勒三家医院的成年患者在胸部和腰椎期间的入口表面剂量(ESD)和有效剂量(ED)。材料与方法:本研究在埃尔比勒三所公立医院对250例年龄在18-70岁之间的成年患者进行研究,根据研究结果计算胸部(侧位)和腰椎(侧位)检查的ESD和ED。NOMEX万用表(PTW, Freiburg),用于在检查过程中自动测量管电压,剂量,剂量率,时间产物电流和总过滤。采用PCXMC软件(2.5版)计算ED。结果:本研究结果与国际上已发表的文献进行了比较。检查胸部(PA, Lat)和腰椎(AP, Lat)的平均皮肤入口剂量分别为1.02、1.06、2.61和3.92 mGy。胸部(PA, Lat)和腰椎(AP, Lat)的ED值分别为0.08,0.19,0.32和0.33 mSv。结论:本文计算的ESD、ED与国际上公布的胸椎、腰椎参考值一致。为减少成人影像学患者的吸收剂量,放射技师应考虑ALARA原则。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Brain Magnetic Resonance Imaging Findings in Chronic Kidney Disease Patients with and without Parkinsonism: A Case-Control Study Investigating the Level of Knowledge and Attitude towards Basic Life Supports and Related Factors in Surgical Technologists and Nurses of Anesthesia at Imam Khomeini Hospital at Tehran during COVID-19 Pandemic Thyroid Nodule Correlation with Serum Prolactin and TPO Antibody Levels: A Case-Control Study Climate Change and the Looming Threat of Cardiovascular Diseases in Iran: A Narrative Review Examining the Knowledge, Attitude, and Performance of Operating Room Personnel about the Use of Personal Communication Devices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1