Extracting 3D Angiography Data from Simulated Computed Tomography Angiography Scans Using Low Iodine Contrast Agent

A. Alyassin
{"title":"Extracting 3D Angiography Data from Simulated Computed Tomography Angiography Scans Using Low Iodine Contrast Agent","authors":"A. Alyassin","doi":"10.4236/ijmpcero.2022.113012","DOIUrl":null,"url":null,"abstract":"The purpose of this research is to investigate the feasibility of using low contrast agent concentration with X-ray computed tomography in visualizing and diagnosing the human vascular system while minimizing the risk of tox-icity to the patient. This research investigated the effect of several iodine contrast agent concentrations on the ability to extract and visualize human vessels using simulated computed tomography scans. Monte Carlo simulation was used to perform these computed tomography acquisitions. The simulated patient was based on actual computed tomography angiography data, where a technique was developed to simulate brain vessels with contrast agents rang-ing from 0 mg to 20 mg of iodine. The simulation used segmented patient data along with basic image processing techniques to model the various levels of iodine concentrations. Cone beam computed tomography projections of a patient injected with and without iodine were acquired in the simulations. Subtraction of the corresponding projections was performed to generate images caused by the contrast agent. Then, histogram analysis of these differ-ences was used to assess the validity of extracting and visualizing the human vessels. The smallest amount of iodine, 0.5 mg, helped better visualize the brain vessels and 2 mg of iodine was high enough to show almost 90% of the vessels. Additionally, the vessels were clearly visible in all the subtracted images. This research showed very promising outcomes in using low concentrations of iodine. Thus, this study proposes for the pharmaceutical companies and others interested to clinically investigate and evaluate the efficacy of using low concentrations of iodine and the associated side effects.","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/ijmpcero.2022.113012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of this research is to investigate the feasibility of using low contrast agent concentration with X-ray computed tomography in visualizing and diagnosing the human vascular system while minimizing the risk of tox-icity to the patient. This research investigated the effect of several iodine contrast agent concentrations on the ability to extract and visualize human vessels using simulated computed tomography scans. Monte Carlo simulation was used to perform these computed tomography acquisitions. The simulated patient was based on actual computed tomography angiography data, where a technique was developed to simulate brain vessels with contrast agents rang-ing from 0 mg to 20 mg of iodine. The simulation used segmented patient data along with basic image processing techniques to model the various levels of iodine concentrations. Cone beam computed tomography projections of a patient injected with and without iodine were acquired in the simulations. Subtraction of the corresponding projections was performed to generate images caused by the contrast agent. Then, histogram analysis of these differ-ences was used to assess the validity of extracting and visualizing the human vessels. The smallest amount of iodine, 0.5 mg, helped better visualize the brain vessels and 2 mg of iodine was high enough to show almost 90% of the vessels. Additionally, the vessels were clearly visible in all the subtracted images. This research showed very promising outcomes in using low concentrations of iodine. Thus, this study proposes for the pharmaceutical companies and others interested to clinically investigate and evaluate the efficacy of using low concentrations of iodine and the associated side effects.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用低碘造影剂从模拟计算机断层血管造影扫描中提取3D血管造影数据
本研究的目的是探讨使用低浓度造影剂与x线计算机断层扫描在可视化和诊断人体血管系统的可行性,同时尽量减少对患者的毒性风险。本研究调查了几种碘造影剂浓度对利用模拟计算机断层扫描提取和可视化人体血管的能力的影响。蒙特卡罗模拟用于执行这些计算机断层扫描采集。模拟的患者是基于实际的计算机断层扫描血管造影数据,其中开发了一种技术,用对比剂从0毫克到20毫克的碘来模拟脑血管。模拟使用分段的病人数据以及基本的图像处理技术来模拟不同水平的碘浓度。在模拟中获得了注射和不注射碘的患者的锥束计算机断层扫描投影。对相应的投影进行相减,生成由造影剂引起的图像。然后,对这些差异进行直方图分析,以评估提取和可视化人体血管的有效性。最少量的碘(0.5毫克)有助于更好地显示脑血管,而2毫克的碘足以显示几乎90%的血管。此外,在所有减去的图像中,血管都清晰可见。这项研究显示了使用低浓度碘的非常有希望的结果。因此,本研究建议制药公司和其他感兴趣的人进行临床调查和评估使用低浓度碘的功效和相关的副作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assessment of Monitor Units and Gamma Pass Rate for 6 MV and Flattening Filter Free (FFF) Beams in Volumetric Modulated Arc Therapy (VMAT) The Journey of SRS: An Initial Experience of Starting Sterotactic Radiosurgery Facility at Purbanchal Cancer Hospital—First in Nepal Hereditary Multiple Exostoses (HME) with Peroneal Nerve Compresion: A Case Report Dosimetric Study of the Effect of Calypso-Compatible Couch Top for Spine Stereotactic Body Radiation Therapy Radiation-Associated Cardiotoxicity during Breast Cancer Treatment with Ionizing Radiation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1