Effect of Frequency on Eddy Losses of Transformers

Yildirim Özüpak
{"title":"Effect of Frequency on Eddy Losses of Transformers","authors":"Yildirim Özüpak","doi":"10.24107/IJEAS.879095","DOIUrl":null,"url":null,"abstract":"Transformer is a vital component of electrical power systems for transmission and distribution. Robust design to increase the efficiency of a transformer is one of the main factors in transformer manufacturing. The efficiency of a practical transformer is limited by the losses caused by design and manufacturing defects. Losses in transformers can be divided into idle losses and losses under load. Eddy current loss is obtained from the idle losses of the transformer. In this paper, the effect of eddy effect causing HV energy loss at high magnetization frequencies was investigated. ANSYS@Maxwell software based on the Finite Element Method was used to analyze the eddy current loss in a T-connected, 3-leg and 3-phase distribution transformer of 15 MVA. The losses are obtained from no-load tests by changing the operating frequency of the transformer. Depending on the frequency value in the range of 50-60 Hz, the change in eddy current loss has been observed while the transformer winding is excitation at 1.74 T magnetic flux density. It has been observed that increasing the frequency causes an increase in the no load loss in the 3-phase transformer.","PeriodicalId":34399,"journal":{"name":"International Journal of Electrical Engineering and Applied Sciences","volume":"54 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Electrical Engineering and Applied Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24107/IJEAS.879095","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Transformer is a vital component of electrical power systems for transmission and distribution. Robust design to increase the efficiency of a transformer is one of the main factors in transformer manufacturing. The efficiency of a practical transformer is limited by the losses caused by design and manufacturing defects. Losses in transformers can be divided into idle losses and losses under load. Eddy current loss is obtained from the idle losses of the transformer. In this paper, the effect of eddy effect causing HV energy loss at high magnetization frequencies was investigated. ANSYS@Maxwell software based on the Finite Element Method was used to analyze the eddy current loss in a T-connected, 3-leg and 3-phase distribution transformer of 15 MVA. The losses are obtained from no-load tests by changing the operating frequency of the transformer. Depending on the frequency value in the range of 50-60 Hz, the change in eddy current loss has been observed while the transformer winding is excitation at 1.74 T magnetic flux density. It has been observed that increasing the frequency causes an increase in the no load loss in the 3-phase transformer.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
频率对变压器涡流损耗的影响
变压器是输配电电力系统的重要组成部分。提高变压器效率的稳健设计是变压器制造的主要因素之一。实际变压器的效率受到设计和制造缺陷造成的损耗的限制。变压器的损耗可分为空闲损耗和有载损耗。涡流损耗来源于变压器的空闲损耗。本文研究了高磁化频率下涡流效应对高压能量损失的影响。采用基于有限元法的ANSYS@Maxwell软件对15mva的t接三支腿三相配电变压器涡流损耗进行了分析。通过改变变压器的工作频率,从空载试验中获得损耗。根据50-60 Hz范围内的频率值,可以观察到变压器绕组在1.74 T磁通密度下励磁时涡流损耗的变化。已经观察到,增加频率会导致三相变压器空载损耗增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
期刊最新文献
Effects of Coating Aggregates on Dynamic Properties of Concrete by Impact Resonance Method Vibration analysis of porous orthotropic cylindrical panels resting on elastic foundations based on shear deformation theory Behavior of Composite Parts Adhesively Joined With Single Lap Joint and Intermediated Material Under Tensile Load Mechanical and Optical Properties of Multiwall Carbon Nanotube-Reinforced ZA27-Al2O3 Hybrid Composites Fabricated by Powder Metallurgy Routine Time-Dependent Reliability Analysis for Deflection of a Reinforced Concrete Box Girder Bridge
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1